메뉴 건너뛰기




Volumn 7, Issue 5, 1998, Pages 400-407

The role of supplemental translaminar screws in anterior lumbar interbody fixation: A biomechanical study

Author keywords

Biomechanics; Implant; Interbody fusion; Stability; Translaminar screws

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; HUMAN; HUMAN TISSUE; JOINT STABILITY; PRIORITY JOURNAL; SPINE FUSION; WEIGHT BEARING;

EID: 0031764138     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s005860050097     Document Type: Article
Times cited : (72)

References (28)
  • 1
    • 0027423357 scopus 로고
    • A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients
    • Brantigan JW, Steffee AD (1993) A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine 18:2106-2107
    • (1993) Spine , vol.18 , pp. 2106-2107
    • Brantigan, J.W.1    Steffee, A.D.2
  • 2
    • 0031013415 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion. A biomechanical comparison, including a new threaded titanium cage
    • Brodke DS, Dick JC, Kunz DN, McCabe R, Zdeblick TA (1997) Posterior lumbar interbody fusion. A biomechanical comparison, including a new threaded titanium cage. Spine 22:26-31
    • (1997) Spine , vol.22 , pp. 26-31
    • Brodke, D.S.1    Dick, J.C.2    Kunz, D.N.3    McCabe, R.4    Zdeblick, T.A.5
  • 6
    • 0023616509 scopus 로고
    • Biomechanical comparison of seven internal fixation devices for the lumbosacral junction
    • Guyer DW, Yuan HA, Werner FW, Frederickson BE, Murphy D (1987) Biomechanical comparison of seven internal fixation devices for the lumbosacral junction. Spine 12:569-573
    • (1987) Spine , vol.12 , pp. 569-573
    • Guyer, D.W.1    Yuan, H.A.2    Werner, F.W.3    Frederickson, B.E.4    Murphy, D.5
  • 7
    • 0025804804 scopus 로고
    • Translaminar facet joint screw fixation for lumbar and lumbosacral fusion - A clinical and biomechanical study
    • Heggeness MH, Esses SI (1991) Translaminar facet joint screw fixation for lumbar and lumbosacral fusion - a clinical and biomechanical study. Spine 16:5266-269
    • (1991) Spine , vol.16 , pp. 5266-5269
    • Heggeness, M.H.1    Esses, S.I.2
  • 8
    • 0027979820 scopus 로고
    • Anterior lumbar fusion using a hybrid interbody graft. a preliminary radiographic report
    • Holte DC, O'Brien JP, Renton (1994) Anterior lumbar fusion using a hybrid interbody graft. A preliminary radiographic report. Eur Spine J 3:32-38
    • (1994) Eur Spine J , vol.3 , pp. 32-38
    • Holte, D.C.1    O'Brien, J.P.2    Renton3
  • 9
    • 0024490310 scopus 로고
    • Enhancement of lumbar spine fusion by use of translaminar facet joint screws
    • Jacobs RR, Montesano PX, Jackson RP (1989) Enhancement of lumbar spine fusion by use of translaminar facet joint screws. Spine 14:12-15
    • (1989) Spine , vol.14 , pp. 12-15
    • Jacobs, R.R.1    Montesano, P.X.2    Jackson, R.P.3
  • 11
    • 0031911788 scopus 로고    scopus 로고
    • Interbody cage stabilization in the lumbar spine: A biomechanical evaluation of cage design, posterior instrumentation and bone density
    • Br
    • Lund T, Oxland T, Jost B, Cripton P, Grassmann S, Euer C, Nolte LP (1998) Interbody cage stabilization in the lumbar spine: a biomechanical evaluation of cage design, posterior instrumentation and bone density. J Bone Joint Surg [Br] 80:351-359
    • (1998) J Bone Joint Surg , vol.80 , pp. 351-359
    • Lund, T.1    Oxland, T.2    Jost, B.3    Cripton, P.4    Grassmann, S.5    Euer, C.6    Nolte, L.P.7
  • 12
    • 15144349054 scopus 로고    scopus 로고
    • The effect of the external spinal fixator on anterior column motion. A biomechanical study
    • Zurich, October 16-19
    • Lund T, Rathonyi GC, Oxland TR (1996) The effect of the external spinal fixator on anterior column motion. A biomechanical study. European Spine Society Meeting, Zurich, October 16-19
    • (1996) European Spine Society Meeting
    • Lund, T.1    Rathonyi, G.C.2    Oxland, T.R.3
  • 13
    • 0025771167 scopus 로고
    • A paradigm of delayed union and nonunion in the lumbosacral joint. A study of motion and hone grafting of the lumbosacral spine in sheep
    • Nagel DA, Kramers PC, Rann BA, Cordey J, Perren SM (1991) A paradigm of delayed union and nonunion in the lumbosacral joint. A study of motion and hone grafting of the lumbosacral spine in sheep. Spine 16:553-559
    • (1991) Spine , vol.16 , pp. 553-559
    • Nagel, D.A.1    Kramers, P.C.2    Rann, B.A.3    Cordey, J.4    Perren, S.M.5
  • 14
    • 0027443595 scopus 로고
    • A biomechanical comparison of cervical lamino-plasty and cervical laminectomy with progressive facetectomy
    • Nowinski GP, Visarius H, Nolte LP, Herkowitz HN (1993) A biomechanical comparison of cervical lamino-plasty and cervical laminectomy with progressive facetectomy. Spine 18: 1995-2004
    • (1993) Spine , vol.18 , pp. 1995-2004
    • Nowinski, G.P.1    Visarius, H.2    Nolte, L.P.3    Herkowitz, H.N.4
  • 15
    • 0003327917 scopus 로고    scopus 로고
    • The BAK interbody fusion system: Biomechanical rationale and early clinical results
    • Margulies JM, Floman Y, Farcy J-PC, Neuwirth MG (eds). Lippincott-Raven, Philadelphia
    • Oxland TR, Kuslich SD, Kohrs DW, Bagby GW (1996) The BAK interbody fusion system: biomechanical rationale and early clinical results. In: Margulies JM, Floman Y, Farcy J-PC, Neuwirth MG (eds) Lumbosacral and spinopelvic fixation. Lippincott-Raven, Philadelphia, pp 545-65
    • (1996) Lumbosacral and Spinopelvic Fixation , pp. 545-565
    • Oxland, T.R.1    Kuslich, S.D.2    Kohrs, D.W.3    Bagby, G.W.4
  • 16
    • 0024538593 scopus 로고
    • Spinal stability and intersegmental muscle forces: A biomechanical model
    • Panjabi M, Abumi K, Duranceau J, Oxland T (1989) Spinal stability and intersegmental muscle forces: a biomechanical model. Spine 14:194-200
    • (1989) Spine , vol.14 , pp. 194-200
    • Panjabi, M.1    Abumi, K.2    Duranceau, J.3    Oxland, T.4
  • 17
    • 0028350725 scopus 로고
    • Mechanical behavior of the human lumbar and lumbo-sacral spine as shown by three-dimensional load-displacement curves
    • Am
    • Panjabi M, Oxland TR, Yamamoto I, Crisco JJ (1994) Mechanical behavior of the human lumbar and lumbo-sacral spine as shown by three-dimensional load-displacement curves. J Bone Joint Surg [Am] 76:413-424
    • (1994) J Bone Joint Surg , vol.76 , pp. 413-424
    • Panjabi, M.1    Oxland, T.R.2    Yamamoto, I.3    Crisco, J.J.4
  • 18
    • 0026262340 scopus 로고
    • Biomechanical stability of five pedicle fixation systems in a human lumbar spine instability model
    • Panjabi MM, Yamamoto I, Oxland TR, Crisco JJ, Freedman D (1991) Biomechanical stability of five pedicle fixation systems in a human lumbar spine instability model. Clin Biomech 6:197-205
    • (1991) Clin Biomech , vol.6 , pp. 197-205
    • Panjabi, M.M.1    Yamamoto, I.2    Oxland, T.R.3    Crisco, J.J.4    Freedman, D.5
  • 19
    • 0030910461 scopus 로고    scopus 로고
    • Threaded titanium cages for lumbar interbody fusions
    • Ray CD (1997) Threaded titanium cages for lumbar interbody fusions. Spine 22:667-679
    • (1997) Spine , vol.22 , pp. 667-679
    • Ray, C.D.1
  • 20
    • 0027464876 scopus 로고
    • Translaminar facet screw fixation in lumbar spine fusion
    • Reich SM, Kuflik P, Neuwirth M (1993) Translaminar facet screw fixation in lumbar spine fusion. Spine 18: 444-449
    • (1993) Spine , vol.18 , pp. 444-449
    • Reich, S.M.1    Kuflik, P.2    Neuwirth, M.3
  • 21
    • 67649345185 scopus 로고
    • An improved Bonferroni procedure for multiple tests of significance
    • Simes RJ (1986) An improved Bonferroni procedure for multiple tests of significance. Biometrika 73:751-754
    • (1986) Biometrika , vol.73 , pp. 751-754
    • Simes, R.J.1
  • 22
    • 0024362147 scopus 로고
    • Donor site pain from the ilium. A complication of lumbar spine fusion
    • Br
    • Summers BN, Eisenstein SM (1987) Donor site pain from the ilium. A complication of lumbar spine fusion. J Bone Joint Surg [Br] 71: 677-680
    • (1987) J Bone Joint Surg , vol.71 , pp. 677-680
    • Summers, B.N.1    Eisenstein, S.M.2
  • 23
    • 0028793906 scopus 로고
    • Biomechanical properties of threaded insert for lumbar interbody spinal fusion
    • Tencer AF, Hampton D, Eddy S (1995) Biomechanical properties of threaded insert for lumbar interbody spinal fusion. Spine 20:2408-2414
    • (1995) Spine , vol.20 , pp. 2408-2414
    • Tencer, A.F.1    Hampton, D.2    Eddy, S.3
  • 24
    • 0030476303 scopus 로고    scopus 로고
    • Transfacet screw with lumbar interbody reconstruction: Biomechanical study of motion segment stiffness
    • Volkman T, Horton WC, Hutton WC (1996) Transfacet screw with lumbar interbody reconstruction: biomechanical study of motion segment stiffness. J Spinal Disord 9:425-432
    • (1996) J Spinal Disord , vol.9 , pp. 425-432
    • Volkman, T.1    Horton, W.C.2    Hutton, W.C.3
  • 25
  • 28
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion. Preliminary results
    • Zdeblick TA (1993) A prospective, randomized study of lumbar fusion. Preliminary results. Spine 18:983-991
    • (1993) Spine , vol.18 , pp. 983-991
    • Zdeblick, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.