메뉴 건너뛰기




Volumn 115, Issue 5, 1998, Pages 1305-

Duplex ultrasonography in predicting patency of TIPS [1]

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; BLOOD FLOW VELOCITY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ECHOGRAPHY; ENDOSCOPY; HUMAN; LETTER; PORTAL VEIN BLOOD FLOW; PORTOSYSTEMIC ANASTOMOSIS; PRIORITY JOURNAL; STENOSIS;

EID: 0031762356     PISSN: 00165085     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0016-5085(98)70117-9     Document Type: Letter
Times cited : (3)

References (12)
  • 1
    • 0031957293 scopus 로고    scopus 로고
    • The inaccuracy of duplex ultrasonography in predicting patency of transjugular intrahepatic portosystemic shunts
    • CA Owens C Bartolone DL Warner The inaccuracy of duplex ultrasonography in predicting patency of transjugular intrahepatic portosystemic shunts Gastroenterology 114 1998 975 980
    • (1998) Gastroenterology , vol.114 , pp. 975-980
    • Owens, CA1    Bartolone, C2    Warner, DL3
  • 2
    • 0027367202 scopus 로고
    • Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity
    • WK Chong TA Malisch MJ Mazer Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity Radiology 189 1993 789 793
    • (1993) Radiology , vol.189 , pp. 789-793
    • Chong, WK1    Malisch, TA2    Mazer, MJ3
  • 3
    • 0028260143 scopus 로고
    • Incidence of shunt occlusion or stenosis following transjugular intrahepatic portosystemic shunt placement
    • CD Lind TW Malisch WK Chong Incidence of shunt occlusion or stenosis following transjugular intrahepatic portosystemic shunt placement Gastroenterology 106 1994 1277 1283
    • (1994) Gastroenterology , vol.106 , pp. 1277-1283
    • Lind, CD1    Malisch, TW2    Chong, WK3
  • 4
    • 0028909884 scopus 로고
    • Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex doppler sonography
    • GD Dodd III AB Zajko PD Orons Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex doppler sonography Am J Roentgenol 164 1995 1119 1124
    • (1995) Am J Roentgenol , vol.164 , pp. 1119-1124
    • Dodd, GD1    Zajko, AB2    Orons, PD3
  • 5
    • 0028956285 scopus 로고
    • Short- and long-term hemodynamic effects of transjugular intrahepatic portosystemic shunts: a doppler/manometric correlative study
    • M Lafortune J-P Martinet A Denys Short- and long-term hemodynamic effects of transjugular intrahepatic portosystemic shunts: a doppler/manometric correlative study Am J Roentgenol 164 1995 997 1002
    • (1995) Am J Roentgenol , vol.164 , pp. 997-1002
    • Lafortune, M1    Martinet, J-P2    Denys, A3
  • 6
    • 0029836210 scopus 로고    scopus 로고
    • Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses
    • VA Feldstein MD Patel JM LaBerge Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses Radiology 201 1996 141 147
    • (1996) Radiology , vol.201 , pp. 141-147
    • Feldstein, VA1    Patel, MD2    LaBerge, JM3
  • 7
    • 0031019466 scopus 로고    scopus 로고
    • Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction
    • RY Kanterman MD Darcy WD Middleton Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction Am J Roentgenol 168 1997 467 472
    • (1997) Am J Roentgenol , vol.168 , pp. 467-472
    • Kanterman, RY1    Darcy, MD2    Middleton, WD3
  • 8
    • 0031041533 scopus 로고    scopus 로고
    • The natural history of portal hypertension after transjugular intrahepatic portosystemic shunts
    • AJ Sanyal AM Freedman VA Luketic The natural history of portal hypertension after transjugular intrahepatic portosystemic shunts Gastroenterology 112 1997 889 898
    • (1997) Gastroenterology , vol.112 , pp. 889-898
    • Sanyal, AJ1    Freedman, AM2    Luketic, VA3
  • 9
    • 0031806037 scopus 로고    scopus 로고
    • Doppler-sonographische Kurz- und Langzeituntersuchungen der portalen Hämodynamik nach transjugulärem intrahepatischem portosystemischem Stent-Shunt (TIPS)
    • W Nolte H Münke CG Schindler Doppler-sonographische Kurz- und Langzeituntersuchungen der portalen Hämodynamik nach transjugulärem intrahepatischem portosystemischem Stent-Shunt (TIPS) Z Gastroenterol 1998 (in press)
    • (1998) Z Gastroenterol
    • Nolte, W1    Münke, H2    Schindler, CG3
  • 10
    • 0028235521 scopus 로고
    • Color doppler sonography of transjugular intrahepatic portosystemic shunts (TIPS)
    • MC Foshager H Ferral DE Finlay Color doppler sonography of transjugular intrahepatic portosystemic shunts (TIPS) Am J Roentgenol 163 1994 105 111
    • (1994) Am J Roentgenol , vol.163 , pp. 105-111
    • Foshager, MC1    Ferral, H2    Finlay, DE3
  • 11
    • 0242708394 scopus 로고    scopus 로고
    • Randomised trial of transjugular-intrahepatic-portosystemic shunt versus endoscopy plus propranolol for prevention of variceal rebleeding
    • M Rössle P Deibert K Haag Randomised trial of transjugular-intrahepatic-portosystemic shunt versus endoscopy plus propranolol for prevention of variceal rebleeding Lancet 349 1997 1043 1049
    • (1997) Lancet , vol.349 , pp. 1043-1049
    • Rössle, M1    Deibert, P2    Haag, K3
  • 12
    • 0031966438 scopus 로고    scopus 로고
    • The first decade of the transjugular intrahepatic portosystemic shunt (TIPS): state of the art
    • M Rössle V Siegerstetter M Huber The first decade of the transjugular intrahepatic portosystemic shunt (TIPS): state of the art Liver 18 1998 73 89
    • (1998) Liver , vol.18 , pp. 73-89
    • Rössle, M1    Siegerstetter, V2    Huber, M3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.