메뉴 건너뛰기




Volumn 43, Issue 11, 1998, Pages 986-990

Efficacy of fibrin glue for in vitro sealing of human chorioamniotic membranes

Author keywords

Chorioamniotic membranes; Fetal membranes, premature rupture; Fibrin glue

Indexed keywords

FIBRIN GLUE; SEALANT; THROMBIN;

EID: 0031761944     PISSN: 00247758     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (30)

References (25)
  • 1
    • 0020376238 scopus 로고
    • Premature rupture of membranes
    • Gibbs RS, Blanco JD: Premature rupture of membranes. Obstet Gynecol 1982;60:671-679
    • (1982) Obstet Gynecol , vol.60 , pp. 671-679
    • Gibbs, R.S.1    Blanco, J.D.2
  • 2
    • 0025788326 scopus 로고
    • Management of preterm premature rupture of membranes
    • Asrat T, Garite TJ: Management of preterm premature rupture of membranes. Clin Obstet Gynecol 1991;34:730-741
    • (1991) Clin Obstet Gynecol , vol.34 , pp. 730-741
    • Asrat, T.1    Garite, T.J.2
  • 3
    • 0026654060 scopus 로고
    • Expectant and active management of preterm premature rupture of membranes
    • Malee MP: Expectant and active management of preterm premature rupture of membranes. Obstet Gynecol Clin North Am 1992;19:309-315
    • (1992) Obstet Gynecol Clin North Am , vol.19 , pp. 309-315
    • Malee, M.P.1
  • 4
    • 0026710895 scopus 로고
    • Management of premature rupture of membranes before 26 weeks' gestation
    • Mercer BM: Management of premature rupture of membranes before 26 weeks' gestation. Obstet Gynecol Clin North Am 1992;19:339-351
    • (1992) Obstet Gynecol Clin North Am , vol.19 , pp. 339-351
    • Mercer, B.M.1
  • 5
    • 0025165987 scopus 로고
    • Fibrin glue: The perfect operative sealant?
    • Gibble JW, Ness PM: Fibrin glue: The perfect operative sealant? Transfusion 1990;30:741-747
    • (1990) Transfusion , vol.30 , pp. 741-747
    • Gibble, J.W.1    Ness, P.M.2
  • 6
    • 7844230727 scopus 로고
    • Personal communication
    • Lontz JF: Personal communication, 1992
    • (1992)
    • Lontz, J.F.1
  • 8
    • 0017136294 scopus 로고
    • The mechanical properties of prematurely ruptured membranes: Methods and preliminary results
    • Artal R, Sokol RJ, Neuman M, et al: The mechanical properties of prematurely ruptured membranes: Methods and preliminary results. Am J Obstet Gynecol 1976;125:655-659
    • (1976) Am J Obstet Gynecol , vol.125 , pp. 655-659
    • Artal, R.1    Sokol, R.J.2    Neuman, M.3
  • 10
    • 0022260166 scopus 로고
    • Fibrin seal: The state of the art
    • Matras H: Fibrin seal: The state of the art. J Oral Maxillofac Surg 1985;43:605-611
    • (1985) J Oral Maxillofac Surg , vol.43 , pp. 605-611
    • Matras, H.1
  • 11
    • 0023778096 scopus 로고
    • Clinical use of non-autologous fibrin glue
    • Kram HB, Nathan RC: Clinical use of non-autologous fibrin glue. Am Surg 1988;54:570-574
    • (1988) Am Surg , vol.54 , pp. 570-574
    • Kram, H.B.1    Nathan, R.C.2
  • 12
    • 0006283839 scopus 로고
    • Fibrinogen (human): Revocation of licenses
    • Hile JP: Fibrinogen (human): Revocation of licenses. Fed Reg 1978;43:1131-1135
    • (1978) Fed Reg , vol.43 , pp. 1131-1135
    • Hile, J.P.1
  • 13
    • 0022312971 scopus 로고
    • Preparation of fibrin glue from single-donor fresh frozen plasma
    • Dresdale A, Rose EA: Preparation of fibrin glue from single-donor fresh frozen plasma. Surgery 1985;97:750-755
    • (1985) Surgery , vol.97 , pp. 750-755
    • Dresdale, A.1    Rose, E.A.2
  • 14
    • 0021885564 scopus 로고
    • Hemostatic effectiveness of a fibrin glue derived from single-donor fresh frozen plasma
    • Dresdale A, Bowman FO: Hemostatic effectiveness of a fibrin glue derived from single-donor fresh frozen plasma. Ann Thorac Surg 1985;40:385-387
    • (1985) Ann Thorac Surg , vol.40 , pp. 385-387
    • Dresdale, A.1    Bowman, F.O.2
  • 15
    • 0023261630 scopus 로고
    • Reduction of perioperative hemorrhage by anterior mediastinal spray application of fibrin glue during cardiac operations
    • Spotnitz WD, Dalton MS: Reduction of perioperative hemorrhage by anterior mediastinal spray application of fibrin glue during cardiac operations. Ann Thorac Surg 1978;44:529-531
    • (1978) Ann Thorac Surg , vol.44 , pp. 529-531
    • Spotnitz, W.D.1    Dalton, M.S.2
  • 16
    • 0022368291 scopus 로고
    • Fibrin glue safety: Inactivation of potential viral contaminates by pasteurization of the human plasma components
    • Hilfenhaus J, Weldmann E: Fibrin glue safety: Inactivation of potential viral contaminates by pasteurization of the human plasma components. Arzneimittelforschung 1985;35: 1617-1619
    • (1985) Arzneimittelforschung , vol.35 , pp. 1617-1619
    • Hilfenhaus, J.1    Weldmann, E.2
  • 17
    • 0023609121 scopus 로고
    • A method for preparation of fibrin glue
    • Durham LH, Willatt DJ: A method for preparation of fibrin glue. J Laryngol Otol 1987;101:1182-1186
    • (1987) J Laryngol Otol , vol.101 , pp. 1182-1186
    • Durham, L.H.1    Willatt, D.J.2
  • 18
    • 0026328405 scopus 로고
    • Experimental and clinical application of fibrin glue
    • Saltz R, Sierra D: Experimental and clinical application of fibrin glue. Plast Reconstr Surg 1991;88:1005-1015
    • (1991) Plast Reconstr Surg , vol.88 , pp. 1005-1015
    • Saltz, R.1    Sierra, D.2
  • 19
    • 0026503165 scopus 로고
    • Autologous whole plasma fibrin gel: Intraoperative procurement
    • Hartman AR, Galanakis DK: Autologous whole plasma fibrin gel: Intraoperative procurement. Arch Surg 1992;127: 357-359
    • (1992) Arch Surg , vol.127 , pp. 357-359
    • Hartman, A.R.1    Galanakis, D.K.2
  • 20
    • 0018703653 scopus 로고
    • Treatment of premature rupture of the fetal membranes by means of fibrin adhesion
    • Genz HJ: Treatment of premature rupture of the fetal membranes by means of fibrin adhesion. Med Welt 1979;42: 1557-1559
    • (1979) Med Welt , vol.42 , pp. 1557-1559
    • Genz, H.J.1
  • 22
    • 0019961717 scopus 로고
    • Fibrin sealing: An advanced therapy in dealing with premature rupture of membranes?
    • Kurz CS, Huch A: Fibrin sealing: An advanced therapy in dealing with premature rupture of membranes? J Perinat Med 1982;10:66-70
    • (1982) J Perinat Med , vol.10 , pp. 66-70
    • Kurz, C.S.1    Huch, A.2
  • 23
    • 0022609052 scopus 로고
    • The technique of fibrin adhesion for premature rupture of the membranes during pregnancy
    • Baumgarten K, Moser S: The technique of fibrin adhesion for premature rupture of the membranes during pregnancy. J Perinat Med 1986;14:43-49
    • (1986) J Perinat Med , vol.14 , pp. 43-49
    • Baumgarten, K.1    Moser, S.2
  • 24
    • 0024248927 scopus 로고
    • Sealing with fibrin in cases of premature rupture of the fetal membranes
    • Anger H: Sealing with fibrin in cases of premature rupture of the fetal membranes. Ricerca Clin Lab (suppl 1) 1988;18: 105-108
    • (1988) Ricerca Clin Lab (Suppl 1) , vol.18 , pp. 105-108
    • Anger, H.1
  • 25
    • 0024808665 scopus 로고
    • Problems and practicability of fibrin sealing in early premature rupture of the amniotic membranes: Four cases with different procedure
    • Passloer HJ: Problems and practicability of fibrin sealing in early premature rupture of the amniotic membranes: Four cases with different procedure. Geburtshilfe Frauenheilkd 1989;49:1067-1069
    • (1989) Geburtshilfe Frauenheilkd , vol.49 , pp. 1067-1069
    • Passloer, H.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.