메뉴 건너뛰기




Volumn 7, Issue 4, 1998, Pages 315-319

Development of a 23.5 kHz ultrasonically activated device for laparoscopic surgery

Author keywords

Laparoscopic surgery; Tissue dissection; Ultrasonically activated device; Vessel coagulation; Vessel dissection

Indexed keywords

ADULT; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTERIAL PRESSURE; ARTERY; ARTERY OCCLUSION; ARTICLE; BLEEDING; BLOOD CLOTTING; CASE REPORT; FEMALE; HUMAN; IDIOPATHIC THROMBOCYTOPENIC PURPURA; INTESTINE PRESSURE; LAPAROSCOPIC SURGERY; NONHUMAN; PRIORITY JOURNAL; SPLENECTOMY; STAPLER; SURGICAL EQUIPMENT; SWINE; ULTRASOUND;

EID: 0031760495     PISSN: 13645706     EISSN: None     Source Type: Journal    
DOI: 10.3109/13645709809152874     Document Type: Article
Times cited : (6)

References (6)
  • 1
    • 0027538470 scopus 로고
    • Laparoscopic application of an ultrasonically activated scalpel
    • Amaral JF. Laparoscopic application of an ultrasonically activated scalpel. Gastrointest Clin No Am 1993; 3: 381-92.
    • (1993) Gastrointest Clin No Am , vol.3 , pp. 381-392
    • Amaral, J.F.1
  • 2
    • 0028213002 scopus 로고
    • The experimental development of an ultrasonically activated scalpel for laparoscopic use
    • Amaral JF. The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Lap Endoscopy 1994; 4: 92-9.
    • (1994) Surg Lap Endoscopy , vol.4 , pp. 92-99
    • Amaral, J.F.1
  • 3
    • 0028458152 scopus 로고
    • Ultrasonic dissection
    • Amaral JF. Ultrasonic dissection. End Surg 1994; 2: 181-5.
    • (1994) End Surg , vol.2 , pp. 181-185
    • Amaral, J.F.1
  • 4
    • 0006314331 scopus 로고    scopus 로고
    • Basic experiments to evaluate safety of the 55.5 kHz ultrasonically activated instrument and its application in laparoscopic gastric surgery
    • Kanehira E, Omura K, Miyanaga T, Mori A, Kinoshita T, Watanabe Y. Basic experiments to evaluate safety of the 55.5 kHz ultrasonically activated instrument and its application in laparoscopic gastric surgery. JSES 1997; 2: 239-44.
    • (1997) JSES , vol.2 , pp. 239-244
    • Kanehira, E.1    Omura, K.2    Miyanaga, T.3    Mori, A.4    Kinoshita, T.5    Watanabe, Y.6
  • 5
    • 0028931711 scopus 로고
    • The ability of laparoscopic clips to withstand high intraluminal pressure
    • Deans GT, Wilson MS, Brough WA. The ability of laparoscopic clips to withstand high intraluminal pressure. Arch Surg 1995; 130: 439-41.
    • (1995) Arch Surg , vol.130 , pp. 439-441
    • Deans, G.T.1    Wilson, M.S.2    Brough, W.A.3
  • 6
    • 0031990905 scopus 로고    scopus 로고
    • The use of bipolar cautery, laparosonic coagulating shears, and vascular clips for haemostasis of small and medium-sized vessels
    • Spivak H, Richardson WS, Hunter JG. The use of bipolar cautery, laparosonic coagulating shears, and vascular clips for haemostasis of small and medium-sized vessels. Surg Endsc 1998; 12: 183-5.
    • (1998) Surg Endsc , vol.12 , pp. 183-185
    • Spivak, H.1    Richardson, W.S.2    Hunter, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.