메뉴 건너뛰기




Volumn 18, Issue 4, 1998, Pages 415-418

Tenckhoff catheter salvage by closed stiff-wire manipulation without fluoroscopic control

Author keywords

Closed manipulation; Tenckhoff catheter

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; FEMALE; FLUOROSCOPY; GENERAL ANESTHESIA; GUIDE WIRE; HUMAN; MALE; PERITONEAL CATHETER; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TECHNIQUE;

EID: 0031758326     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686089801800411     Document Type: Article
Times cited : (19)

References (9)
  • 1
    • 0014004661 scopus 로고
    • Treatment of chronic renal failure by prolonged peritoneal dialysis
    • Palmer R, Newel J, Gray J, Quinton W. Treatment of chronic renal failure by prolonged peritoneal dialysis. N Engl J Med 1966; 274:248-54.
    • (1966) N Engl J Med , vol.274 , pp. 248-254
    • Palmer, R.1    Newel, J.2    Gray, J.3    Quinton, W.4
  • 2
    • 0014384927 scopus 로고
    • A bacteriologically safe peritoneal access device
    • Tenckhoff H, Schechtec H. A bacteriologically safe peritoneal access device. ASAIO Trans 1968; 14:181-7.
    • (1968) ASAIO Trans , vol.14 , pp. 181-187
    • Tenckhoff, H.1    Schechtec, H.2
  • 3
    • 0020448986 scopus 로고
    • The Tenckhoff catheter for peritoneal dialysis - An appraisal
    • Rubin J, Adair C, Ragu S, Bower JD. The Tenckhoff catheter for peritoneal dialysis - an appraisal. Nephron 1982; 32:370-4.
    • (1982) Nephron , vol.32 , pp. 370-374
    • Rubin, J.1    Adair, C.2    Ragu, S.3    Bower, J.D.4
  • 5
    • 0025100602 scopus 로고
    • Malpositioned peritoneal dialysis catheters: A critical re-appraisal of correction by stiff wire manipulation
    • Moss JS, Minda SA, Newman GE, Dunnick NR, Vernon WB, Schwab SJ. Malpositioned peritoneal dialysis catheters: a critical re-appraisal of correction by stiff wire manipulation. Am J Kidney Dis 1990; 15:305-8.
    • (1990) Am J Kidney Dis , vol.15 , pp. 305-308
    • Moss, J.S.1    Minda, S.A.2    Newman, G.E.3    Dunnick, N.R.4    Vernon, W.B.5    Schwab, S.J.6
  • 6
    • 0018897535 scopus 로고
    • Tenckhoff peritoneal dialysis catheter cannulography and manipulation
    • Jaques P, Richey W, Mandel S. Tenckhoff peritoneal dialysis catheter cannulography and manipulation. Am J Radiol 1980; 135:83-6.
    • (1980) Am J Radiol , vol.135 , pp. 83-86
    • Jaques, P.1    Richey, W.2    Mandel, S.3
  • 7
    • 0025580547 scopus 로고
    • Reposition of a displaced peritoneal catheter: The Helsinki whiplash method
    • Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG, eds. Toronto: Peritoneal Dialysis Bulletin
    • Honkanen E, Eklund B, Laasonen L, Ylinen K, Gronhagen-Riska C. Reposition of a displaced peritoneal catheter: the Helsinki whiplash method. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG, eds. Advances in peritoneal dialysis. Toronto: Peritoneal Dialysis Bulletin, 1990; 6:159-64.
    • (1990) Advances in Peritoneal Dialysis , vol.6 , pp. 159-164
    • Honkanen, E.1    Eklund, B.2    Laasonen, L.3    Ylinen, K.4    Gronhagen-Riska, C.5
  • 8
    • 0021916777 scopus 로고
    • Tenckhoff peritoneal dialysis catheters: The use of fluoroscopy in management
    • Degesys G, Miller G, Ford K, Dunnick NR. Tenckhoff peritoneal dialysis catheters: the use of fluoroscopy in management. Radiology 1985; 154:819-20.
    • (1985) Radiology , vol.154 , pp. 819-820
    • Degesys, G.1    Miller, G.2    Ford, K.3    Dunnick, N.R.4
  • 9
    • 0023614807 scopus 로고
    • Radiological manipulation of dislodged Tenckhoff dialysis catheters
    • List A. Radiological manipulation of dislodged Tenckhoff dialysis catheters. Australas Radiol 1987; 31:421-3.
    • (1987) Australas Radiol , vol.31 , pp. 421-423
    • List, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.