메뉴 건너뛰기




Volumn 82, Issue 11, 1998, Pages 1260-1264

Screening for abnormal levels of hyperopia in children: A non-cycloplegic method with a hand held refractor

Author keywords

[No Author keywords available]

Indexed keywords

ACCOMMODATION; ACCOMMODATION PARALYSIS; ARTICLE; CLINICAL TRIAL; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; HUMAN; HYPERMETROPIA; INFANT; MAJOR CLINICAL STUDY; MALE; PRESCHOOL CHILD; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; REFRACTION ERROR; REPRODUCIBILITY; SCREENING;

EID: 0031758045     PISSN: 00071161     EISSN: None     Source Type: Journal    
DOI: 10.1136/bjo.82.11.1260     Document Type: Article
Times cited : (49)

References (22)
  • 2
    • 0029563277 scopus 로고
    • Assessment of an inner city visual screening programme for preschool children
    • Williamson TH, Andrews R, Dutton GN, et al. Assessment of an inner city visual screening programme for preschool children. Br J Ophthalmol 1995;79:1068-73.
    • (1995) Br J Ophthalmol , vol.79 , pp. 1068-1073
    • Williamson, T.H.1    Andrews, R.2    Dutton, G.N.3
  • 3
    • 0030029550 scopus 로고    scopus 로고
    • Baltimore vision screening project
    • Preslan MW, Novak A. Baltimore vision screening project. Ophthalmology 1996;103:105-9.
    • (1996) Ophthalmology , vol.103 , pp. 105-109
    • Preslan, M.W.1    Novak, A.2
  • 4
    • 0017353953 scopus 로고
    • Refraction as a basis for screening children for squint and amblyopia
    • Ingram RM. Refraction as a basis for screening children for squint and amblyopia. Br J Ophthalmol 1977,61:8-15
    • (1977) Br J Ophthalmol , vol.61 , pp. 8-15
    • Ingram, R.M.1
  • 5
    • 0019034947 scopus 로고
    • Ophthalmic screening of 38,000 children, age 1 to 2 1/2 years, in child welfare clinics
    • Friedman Z, Neumann E, Hyams SW, et at. Ophthalmic screening of 38,000 children, age 1 to 2 1/2 years, in child welfare clinics. J Pediatr Ophthalmol Strabismus 1980;17: 261-7.
    • (1980) J Pediatr Ophthalmol Strabismus , vol.17 , pp. 261-267
    • Friedman, Z.1    Neumann, E.2    Hyams, S.W.3
  • 6
    • 0021671175 scopus 로고
    • Screening for refractive errors in 6-9 month old infants by photorefraction
    • Atkinson J, Braddick OJ, Durden K, et al. Screening for refractive errors in 6-9 month old infants by photorefraction. Br J Ophthalmol 1984;68:105-12.
    • (1984) Br J Ophthalmol , vol.68 , pp. 105-112
    • Atkinson, J.1    Braddick, O.J.2    Durden, K.3
  • 7
    • 0023707189 scopus 로고
    • Simple retinoscopic screening
    • Olver JM. Simple retinoscopic screening. Eye 1988;2:309-13.
    • (1988) Eye , vol.2 , pp. 309-313
    • Olver, J.M.1
  • 8
    • 0026792803 scopus 로고
    • Results of photorefractometric screening for amblyogenic defects in children aged 20 months
    • Angi MR, Pucci V, Forattini F, et at. Results of photorefractometric screening for amblyogenic defects in children aged 20 months. Behav Brain Res 1992;49:91-7.
    • (1992) Behav Brain Res , vol.49 , pp. 91-97
    • Angi, M.R.1    Pucci, V.2    Forattini, F.3
  • 10
    • 0029950725 scopus 로고    scopus 로고
    • Two infant screening programmes: Prediction and prevention or strabismus and amblyopia from videorefractive screening
    • Atkinson J, Braddick O, Bobier B, et al. Two infant screening programmes: prediction and prevention or strabismus and amblyopia from videorefractive screening. Eye 1996; 10:189-98.
    • (1996) Eye , vol.10 , pp. 189-198
    • Atkinson, J.1    Braddick, O.2    Bobier, B.3
  • 11
    • 0345122861 scopus 로고
    • Automated clinical refraction
    • Philadelphia: Lippincott-Raven, Chapter 67
    • Guyton DL. Automated clinical refraction. Duane's ophthalmology. Clinical. VoI 1. Philadelphia: Lippincott-Raven, Chapter 67, 1983:18.
    • (1983) Duane's Ophthalmology. Clinical , vol.1 , pp. 18
    • Guyton, D.L.1
  • 12
    • 0031893021 scopus 로고    scopus 로고
    • Cycloplegic refractive errors in children:comparison of a standard and a handheld refractor
    • Kallay OP, Cordonnier MJ, Dramaix M. Cycloplegic refractive errors in children:comparison of a standard and a handheld refractor. Strabismus 1998;6:3-7.
    • (1998) Strabismus , vol.6 , pp. 3-7
    • Kallay, O.P.1    Cordonnier, M.J.2    Dramaix, M.3
  • 13
    • 7144259211 scopus 로고    scopus 로고
    • Accuracy of a hand-held autorefractor in the pediatric population
    • Poster presented Ft Lauderdale, Florida, 24 April
    • Wagner LK, Miller JM, Wilson MC, et al. Accuracy of a hand-held autorefractor in the pediatric population. Poster presented at the ARVO Annual Meeting, Ft Lauderdale, Florida, 24 April 1996.
    • (1996) ARVO Annual Meeting
    • Wagner, L.K.1    Miller, J.M.2    Wilson, M.C.3
  • 14
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • Metz CE. Basic principles of ROC analysis. Semin Nucl Med 1978;8:283-98.
    • (1978) Semin Nucl Med , vol.8 , pp. 283-298
    • Metz, C.E.1
  • 15
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil B. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143:29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.2
  • 16
    • 34548054719 scopus 로고
    • Screening degli errori refrattivi ambliogenici con autorefrattometria manifesta in 711 bambini di scuola materna
    • Angi MR, Baravelli S, Bergamo L, et al. Screening degli errori refrattivi ambliogenici con autorefrattometria manifesta in 711 bambini di scuola materna. Bollettino di oculistica 1991,70:191-202.
    • (1991) Bollettino di Oculistica , vol.70 , pp. 191-202
    • Angi, M.R.1    Baravelli, S.2    Bergamo, L.3
  • 17
    • 0030199012 scopus 로고    scopus 로고
    • Preschool vision screening: Rationale, methodology and outcome
    • Simons K. Preschool vision screening: rationale, methodology and outcome. Surv Ophthalmol 1996;41:3-30.
    • (1996) Surv Ophthalmol , vol.41 , pp. 3-30
    • Simons, K.1
  • 18
    • 0003277275 scopus 로고
    • Screening: Relationship to diagnosis and therapy
    • Duane TD, Jaeger EA, eds. Philadelphia: Harper and Row
    • Leske MC, Hawkins B. Screening: relationship to diagnosis and therapy. In: Duane TD, Jaeger EA, eds. Clinical ophthalmology. Philadelphia: Harper and Row, 1994,Vol 5,54:3.
    • (1994) Clinical Ophthalmology , vol.5 , Issue.54 , pp. 3
    • Leske, M.C.1    Hawkins, B.2
  • 19
    • 0011859643 scopus 로고
    • Accommodative measures of ametropia from video-refractive screening of a total infant population
    • Anker SE, Atkinson J, Braddick OJ, et al. Accommodative measures of ametropia from video-refractive screening of a total infant population. Invest Ophthalmol Vis Sci (Suppl) 1995,36:548.
    • (1995) Invest Ophthalmol Vis Sci , vol.36 , Issue.SUPPL. , pp. 548
    • Anker, S.E.1    Atkinson, J.2    Braddick, O.J.3
  • 20
    • 0026968979 scopus 로고
    • Costs and methods of preventive visual screening and the relation between esotropia and increasing hypermetropia
    • Simonsz HJ, Grosklauser B, Leuppi S. Costs and methods of preventive visual screening and the relation between esotropia and increasing hypermetropia. Doc Ophthalmol 1992,82:81-7.
    • (1992) Doc Ophthalmol , vol.82 , pp. 81-87
    • Simonsz, H.J.1    Grosklauser, B.2    Leuppi, S.3
  • 21
    • 0013016052 scopus 로고
    • Infant VPR-1 videorefraction and ocular characteristics of those 'far-focusing' at 75 cm
    • Ehrlich DL, Anker S, Atkinson J, et al. Infant VPR-1 videorefraction and ocular characteristics of those 'far-focusing' at 75 cm. Invest Ophthalmol Vis Sci (Suppl) 1995; 36:548.
    • (1995) Invest Ophthalmol Vis Sci , vol.36 , Issue.SUPPL. , pp. 548
    • Ehrlich, D.L.1    Anker, S.2    Atkinson, J.3
  • 22
    • 0028801394 scopus 로고
    • Early refractive development in humans
    • Saunders KJ. Early refractive development in humans. Surv Ophthamol 1995,40:207-16.
    • (1995) Surv Ophthamol , vol.40 , pp. 207-216
    • Saunders, K.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.