메뉴 건너뛰기




Volumn 40, Issue 6, 1998, Pages 914-921

High-accuracy MR tracking of interventional devices: The overhauser marker enhancement (OMEN) technique

Author keywords

Device visualization; Interventional MRI; Overhauser effect

Indexed keywords

MAGNETIC RESONANCE IMAGING; TISSUE; VISUALIZATION;

EID: 0031757093     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910400618     Document Type: Article
Times cited : (4)

References (30)
  • 3
    • 0028459118 scopus 로고
    • Interventional use of magnetic resonance imaging
    • F. A. Jolesz, S. M. Blumenfeld. Interventional use of magnetic resonance imaging. Magn. Reson. Q. 10, 85-96 (1994).
    • (1994) Magn. Reson. Q. , vol.10 , pp. 85-96
    • Jolesz, F.A.1    Blumenfeld, S.M.2
  • 4
    • 0029392504 scopus 로고
    • Interventional MR imaging
    • R. B. Lufkin, Interventional MR imaging. Radiology 197, 16-18 (1995).
    • (1995) Radiology , vol.197 , pp. 16-18
    • Lufkin, R.B.1
  • 8
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • C. L. Dumoulin, S. P. Souza, R. D. Darrow, Real-time position monitoring of invasive devices using magnetic resonance. Magn. Reson. Med. 29, 411-415 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 9
    • 0025674137 scopus 로고
    • Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging
    • D. L. Rubin, A. V. Ratner, S. W. Young, Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. Invest. Radiol. 25, 1325-1332 (1990).
    • (1990) Invest. Radiol. , vol.25 , pp. 1325-1332
    • Rubin, D.L.1    Ratner, A.V.2    Young, S.W.3
  • 10
    • 0028288337 scopus 로고
    • Vascular interventions guided by ultrafast MR imaging: Evaluation of different materials
    • V. D. Koechli, G. C. McKinnon, E. Hofmann, G. K. von Schulthess, Vascular interventions guided by ultrafast MR imaging: evaluation of different materials. Magn. Reson. Med. 31, 309-313 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 309-313
    • Koechli, V.D.1    McKinnon, G.C.2    Hofmann, E.3    Von Schulthess, G.K.4
  • 11
    • 0029907019 scopus 로고    scopus 로고
    • Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions
    • C. J. Bakker, R. M. Hoogeveen, J. Veber, J. J. van Vaals, M. A. Viergever, W. P. Mali, Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions. Magn. Reson. Med. 36, 816-820 (1996).
    • (1996) Magn. Reson. Med. , vol.36 , pp. 816-820
    • Bakker, C.J.1    Hoogeveen, R.M.2    Veber, J.3    Van Vaals, J.J.4    Viergever, M.A.5    Mali, W.P.6
  • 12
    • 0023903122 scopus 로고
    • A technique for MR-guided needle placement
    • R. Lnfkin, L. Terosi, L. Chiu, W. Hanafee, A technique for MR-guided needle placement. AJR 151, 193-196 (1988).
    • (1988) AJR , vol.151 , pp. 193-196
    • Lnfkin, R.1    Terosi, L.2    Chiu, L.3    Hanafee, W.4
  • 16
    • 0030640155 scopus 로고    scopus 로고
    • Interventional MR imaging: Demonstration of the feasibility of the Overhauser marker enhancement (OMEN) technique
    • R. P. Joensuu, A. E. Lamminen, R. E. Sepponen, C.-G. M. Standertskjöld-Nordenstam. Interventional MR imaging: demonstration of the feasibility of the Overhauser marker enhancement (OMEN) technique. Acta Radiol. 38, 43-46 (1997).
    • (1997) Acta Radiol. , vol.38 , pp. 43-46
    • Joensuu, R.P.1    Lamminen, A.E.2    Sepponen, R.E.3    Standertskjöld-Nordenstam, C.-G.M.4
  • 19
    • 49049134325 scopus 로고
    • The loop-gap resonator: A new microwave lumped circuit ESR sample structure
    • W. Froncisz, J. S. Hyde, The loop-gap resonator: a new microwave lumped circuit ESR sample structure. J. Magn. Reson. 47, 515-521 (1982).
    • (1982) J. Magn. Reson. , vol.47 , pp. 515-521
    • Froncisz, W.1    Hyde, J.S.2
  • 20
    • 0019529861 scopus 로고
    • Split-ring resonator for use in magnetic resonance from 200- 2000 MHz
    • W. N. Hardy, L. A. Whitehead, Split-ring resonator for use in magnetic resonance from 200- 2000 MHz. Rev. Sci. Instrum. 52, 213-216 (1981).
    • (1981) Rev. Sci. Instrum. , vol.52 , pp. 213-216
    • Hardy, W.N.1    Whitehead, L.A.2
  • 21
    • 0020425994 scopus 로고
    • Dispersion electron spin resonance with the loop-gap resonator
    • J. S. Hyde, W. Froncisz, A. Kusumi, Dispersion electron spin resonance with the loop-gap resonator. Rev. Sci. Instrum. 53, 1934-1937 (1982).
    • (1982) Rev. Sci. Instrum. , vol.53 , pp. 1934-1937
    • Hyde, J.S.1    Froncisz, W.2    Kusumi, A.3
  • 22
    • 3142672733 scopus 로고
    • The loop-gap resonator. II. Controlled return flux three-loop, two-gap microwave resonators for ENDOR and ESR spectroscopy
    • R. L. Wood, W. Froncisz, J. S. Hyde, The loop-gap resonator. II. Controlled return flux three-loop, two-gap microwave resonators for ENDOR and ESR spectroscopy. J. Magn. Reson. 58, 243-253 (1984).
    • (1984) J. Magn. Reson. , vol.58 , pp. 243-253
    • Wood, R.L.1    Froncisz, W.2    Hyde, J.S.3
  • 27
    • 0000034571 scopus 로고
    • Dynamic theory of nuclear induction. II
    • F. Bloch, Dynamic theory of nuclear induction. II. Phys. Rev. 102, 104-135 (1956).
    • (1956) Phys. Rev. , vol.102 , pp. 104-135
    • Bloch, F.1
  • 29
    • 0040478424 scopus 로고
    • Dynamic nuclear polarization of water protons by saturation of σ and π EPR transitions of nitroxides
    • T. Guiberteau, D. Grucker, Dynamic nuclear polarization of water protons by saturation of σ and π EPR transitions of nitroxides. J. Magn. Reson. Series A 105, 98-103 (1993).
    • (1993) J. Magn. Reson. Series A , vol.105 , pp. 98-103
    • Guiberteau, T.1    Grucker, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.