메뉴 건너뛰기




Volumn 29, Issue 11, 1998, Pages 904-908

Two-year results of photorefractive keratectomy with scanning spot ablation for myopia of less than -6.0 Diopters

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; DISEASE CLASSIFICATION; FEMALE; FOLLOW UP; HUMAN; KERATECTOMY; MALE; MYOPIA; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE; TREATMENT OUTCOME; VISUAL ACUITY;

EID: 0031755565     PISSN: 10823069     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (15)
  • 2
    • 0024365768 scopus 로고
    • Evolution of excimer laser corneal surgery
    • Trokel SL. Evolution of excimer laser corneal surgery. J Cataract Refract Surg. 1989;15:373-382.
    • (1989) J Cataract Refract Surg , vol.15 , pp. 373-382
    • Trokel, S.L.1
  • 3
    • 0026377426 scopus 로고
    • Central photorefractive keratectomy for myopia: Partially sighted and normally sighted eyes
    • McDonald MB, Liu JC, Byrd TJ, et al. Central photorefractive keratectomy for myopia: partially sighted and normally sighted eyes. Ophthalmology. 1991;98: 1327-1337.
    • (1991) Ophthalmology , vol.98 , pp. 1327-1337
    • McDonald, M.B.1    Liu, J.C.2    Byrd, T.J.3
  • 4
    • 0025989986 scopus 로고
    • Myopic photorefractive keratectomy with the excimer laser: One-year follow-up
    • Seiler T, Wollensak J. Myopic photorefractive keratectomy with the excimer laser: one-year follow-up. Ophthalmology. 1991;98:1156-1163.
    • (1991) Ophthalmology , vol.98 , pp. 1156-1163
    • Seiler, T.1    Wollensak, J.2
  • 5
    • 0026344939 scopus 로고
    • Photorefractive keratectomy with an argon fluoride excimer laser: A clinical study
    • Gartry DS, Kerr Muir MG, Marshall J. Photorefractive keratectomy with an argon fluoride excimer laser: a clinical study. Refract Corneal Surg. 1991;7:420-435.
    • (1991) Refract Corneal Surg , vol.7 , pp. 420-435
    • Gartry, D.S.1    Kerr Muir, M.G.2    Marshall, J.3
  • 6
    • 0029822547 scopus 로고    scopus 로고
    • Ablation smoothness as a function of excimer laser delivery system
    • O'Donnell CB, Kemner J, O'Donnell F. Ablation smoothness as a function of excimer laser delivery system. J Cataract Refract Surg. 1996;22:682-685.
    • (1996) J Cataract Refract Surg , vol.22 , pp. 682-685
    • O'Donnell, C.B.1    Kemner, J.2    O'Donnell, F.3
  • 7
    • 0028040068 scopus 로고
    • Complications of myopic photorefractive keratectomy with the excimer laser
    • Seiler T, Holschbach A, Derse M, et al. Complications of myopic photorefractive keratectomy with the excimer laser. Ophthalmology. 1994;101:153-160.
    • (1994) Ophthalmology , vol.101 , pp. 153-160
    • Seiler, T.1    Holschbach, A.2    Derse, M.3
  • 8
    • 0027994868 scopus 로고
    • One-year results of excimer laser photorefractive keratectomy for low to moderate myopia
    • Dutt S, Steinert RF, Raizman MB, et al. One-year results of excimer laser photorefractive keratectomy for low to moderate myopia. Arch Ophthalmol. 1994;112: 1427-1436.
    • (1994) Arch Ophthalmol , vol.112 , pp. 1427-1436
    • Dutt, S.1    Steinert, R.F.2    Raizman, M.B.3
  • 9
    • 0028200973 scopus 로고
    • Ultraviolet solidstate laser (213-nm) photorefractive keratectomy: In vivo study
    • Ren Q, Simon G, Legeeis JM, et al. Ultraviolet solidstate laser (213-nm) photorefractive keratectomy: in vivo study. Ophthalmology. 1994;101:883-889.
    • (1994) Ophthalmology , vol.101 , pp. 883-889
    • Ren, Q.1    Simon, G.2    Legeeis, J.M.3
  • 10
    • 0002136040 scopus 로고    scopus 로고
    • PRK: Fundamental Concepts and Technology
    • Machat JJ, ed. Thorofare, NJ: SLACK Incorporated
    • Machat JJ. PRK: Fundamental Concepts and Technology. In: Machat JJ, ed. Excimer Laser Refractive Surgery: Practice and Principles. Thorofare, NJ: SLACK Incorporated; 1996:3-46.
    • (1996) Excimer Laser Refractive Surgery: Practice and Principles , pp. 3-46
    • Machat, J.J.1
  • 11
    • 0029914286 scopus 로고    scopus 로고
    • Trackerassisted photorefractive keratectomy for myopia of -1.00 to -6.00 diopters
    • Pallikaris I, McDonald MB, Siganos D, et al. Trackerassisted photorefractive keratectomy for myopia of -1.00 to -6.00 diopters. J Refract Surg. 1996;12: 240-247.
    • (1996) J Refract Surg , vol.12 , pp. 240-247
    • Pallikaris, I.1    McDonald, M.B.2    Siganos, D.3
  • 12
    • 0028020356 scopus 로고
    • Results of excimer laser photorefractive keratectomy for the correction of myopia
    • Maguen E, Salz JJ, Nesburn AB, et al. Results of excimer laser photorefractive keratectomy for the correction of myopia. Ophthalmology. 1994;101: 1548-1556.
    • (1994) Ophthalmology , vol.101 , pp. 1548-1556
    • Maguen, E.1    Salz, J.J.2    Nesburn, A.B.3
  • 13
    • 0026631222 scopus 로고
    • Standardized data collection and reporting for refractive surgery
    • Waring GO III. Standardized data collection and reporting for refractive surgery. Refract Corneal Surg. 1992;8(suppl):1-42.
    • (1992) Refract Corneal Surg , vol.8 , Issue.SUPPL. , pp. 1-42
    • Waring III, G.O.1
  • 14
    • 0027460591 scopus 로고
    • A prototype erodible mask delivery system for the excimer laser
    • Maloney RK, Friedman M, Harmon T, et al. A prototype erodible mask delivery system for the excimer laser. Ophthalmology. 1993;100:542-549.
    • (1993) Ophthalmology , vol.100 , pp. 542-549
    • Maloney, R.K.1    Friedman, M.2    Harmon, T.3
  • 15
    • 17544385185 scopus 로고    scopus 로고
    • Results of phase III excimer laser photorefractive keratectomy for myopia: The Summit PRK Study Group
    • Hersh PS, Stulting RD, Steinert RF, et al. Results of phase III excimer laser photorefractive keratectomy for myopia: the Summit PRK Study Group. Ophthalmology. 1997;104:1535-1553.
    • (1997) Ophthalmology , vol.104 , pp. 1535-1553
    • Hersh, P.S.1    Stulting, R.D.2    Steinert, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.