1
-
-
0014076556
-
Sublethal damage to the red blood cell from pumping
-
Bernstein, E.F., Indeglia, R.A., Shea, M.A., Varco, R.L. Sublethal damage to the red blood cell from pumping. Circulation 1967; 35-36(Suppl. I): 226-233.
-
(1967)
Circulation
, vol.35-36
, Issue.1 SUPPL.
, pp. 226-233
-
-
Bernstein, E.F.1
Indeglia, R.A.2
Shea, M.A.3
Varco, R.L.4
-
3
-
-
0025108735
-
Pathophysiology of cardiopulmonary bypass: Current issues
-
Utley JR. Pathophysiology of cardiopulmonary bypass: current issues. J Cardiac Surg 1990;5:177.
-
(1990)
J Cardiac Surg
, vol.5
, pp. 177
-
-
Utley, J.R.1
-
4
-
-
0027411838
-
Inflammatory response to cardiopulmonary bypass
-
Butler J, Rocker GM, Westaby S. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 1993;55:552-559.
-
(1993)
Ann Thorac Surg
, vol.55
, pp. 552-559
-
-
Butler, J.1
Rocker, G.M.2
Westaby, S.3
-
5
-
-
0021419693
-
A comparison of centrifugal and roller pumps. An experimental study
-
Takeda H, Goda T, Uzawa S, Matsukura H, Sakai K, Tanabe T. A comparison of centrifugal and roller pumps. An experimental study. Jpn J Thorac Surg 1984;37:273-277.
-
(1984)
Jpn J Thorac Surg
, vol.37
, pp. 273-277
-
-
Takeda, H.1
Goda, T.2
Uzawa, S.3
Matsukura, H.4
Sakai, K.5
Tanabe, T.6
-
6
-
-
0028835332
-
Centrifugal and roller pumps - Are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass?
-
Steinbrueckner BE, Steigerwald U, Keller F, Neukam K, Elert O, Babin-Ebell J. Centrifugal and roller pumps - are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass? Heart Vessels 1995;10:46-53.
-
(1995)
Heart Vessels
, vol.10
, pp. 46-53
-
-
Steinbrueckner, B.E.1
Steigerwald, U.2
Keller, F.3
Neukam, K.4
Elert, O.5
Babin-Ebell, J.6
-
7
-
-
0029126532
-
Comparison of the effects of centrifugal versus roller pump on the immune response in open-heart surgery
-
Perttila J, Salo M, Peltola O. Comparison of the effects of centrifugal versus roller pump on the immune response in open-heart surgery. Perfusion 1995;10:249-256.
-
(1995)
Perfusion
, vol.10
, pp. 249-256
-
-
Perttila, J.1
Salo, M.2
Peltola, O.3
-
8
-
-
0030018493
-
Less blood damage in the impeller centrifugal pump: A comparative study with the roller pump in open heart surgery
-
Nishinaka T, Nishida H, Endo M, Miyagishima M, Ohtsuka G, Koyanagi H. Less blood damage in the impeller centrifugal pump: a comparative study with the roller pump in open heart surgery. Artificial Organs 1996;20:707-710.
-
(1996)
Artificial Organs
, vol.20
, pp. 707-710
-
-
Nishinaka, T.1
Nishida, H.2
Endo, M.3
Miyagishima, M.4
Ohtsuka, G.5
Koyanagi, H.6
-
9
-
-
0022627129
-
Influence of the centrifugal pump (Bio-Pump) on blood components: Comparison with roller pump
-
Koja K, Kuniyoshi Y, Ikemura F, Iha K, Kusaba A, Shimabukuro M. et al. Influence of the centrifugal pump (Bio-Pump) on blood components: comparison with roller pump. Jpn J Artific Organs 1986;15:545-548.
-
(1986)
Jpn J Artific Organs
, vol.15
, pp. 545-548
-
-
Koja, K.1
Kuniyoshi, Y.2
Ikemura, F.3
Iha, K.4
Kusaba, A.5
Shimabukuro, M.6
-
10
-
-
0027732923
-
The effects of pressure and flow on haemolysis caused by Bio-Medicus centrifugal pumps and roller pumps
-
Tamari Y, Lee-Sensiba K, Leonard EF, Parnell V, Tortolani AJ. The effects of pressure and flow on haemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. J Thorac Cardiovasc Surg 1993;106:997-1007.
-
(1993)
J Thorac Cardiovasc Surg
, vol.106
, pp. 997-1007
-
-
Tamari, Y.1
Lee-Sensiba, K.2
Leonard, E.F.3
Parnell, V.4
Tortolani, A.J.5
-
11
-
-
0025353436
-
Vortex pumping for routine cardiac surgery: A comparative study
-
Wheeldon DR, Bethune DW, Gill RD. Vortex pumping for routine cardiac surgery: a comparative study. Perfusion 1990;5:135-143.
-
(1990)
Perfusion
, vol.5
, pp. 135-143
-
-
Wheeldon, D.R.1
Bethune, D.W.2
Gill, R.D.3
-
12
-
-
0030018138
-
Comparison of centrifugal and roller pump haemolysis rates at low flow
-
Moon YS, Ohtsubo S, Gomez MR, Moon JK, Nose Y. Comparison of centrifugal and roller pump haemolysis rates at low flow. Artificial Organs 1996;20:579-581.
-
(1996)
Artificial Organs
, vol.20
, pp. 579-581
-
-
Moon, Y.S.1
Ohtsubo, S.2
Gomez, M.R.3
Moon, J.K.4
Nose, Y.5
-
13
-
-
0002427925
-
A method for determination of haemoglobin in plasma by near-ultraviolet spectrophotometry
-
Harboe M. A method for determination of haemoglobin in plasma by near-ultraviolet spectrophotometry. Scand J Clin Lab Invest 1959;11:66-70.
-
(1959)
Scand J Clin Lab Invest
, vol.11
, pp. 66-70
-
-
Harboe, M.1
-
14
-
-
0022656993
-
Thrombin generation during collection and storage of blood
-
Skjonsberg OH, Kierulf P, Fagerhol MK. et al. Thrombin generation during collection and storage of blood. Vox Sang 1986;50:33-37.
-
(1986)
Vox Sang
, vol.50
, pp. 33-37
-
-
Skjonsberg, O.H.1
Kierulf, P.2
Fagerhol, M.K.3
-
15
-
-
0004993129
-
Biologically active peptides of complement techniques and significance of C3a and C5a measurements
-
Nakamura RM, Dito, WR, Tucker III ES, editors. New York:Liss
-
Hugli TE, Chenoweth DE. Biologically active peptides of complement techniques and significance of C3a and C5a measurements. In: Nakamura RM, Dito, WR, Tucker III ES, editors. Future Perspectives in Clinical Laboratory Immunoassays: Clinical Laboratory Techniques for the 1980's. New York:Liss, 1980:443-460.
-
(1980)
Future Perspectives in Clinical Laboratory Immunoassays: Clinical Laboratory Techniques for the 1980's
, pp. 443-460
-
-
Hugli, T.E.1
Chenoweth, D.E.2
-
16
-
-
0027245548
-
Involvement of CD14 in lipopolysaccharide-induced tumour necrosis factor-a, interleukin-6 and interleukin-8 release by human monocytes and alveolar macrophages
-
Dentener MA, Bazil V, Von Asmuth EJU, Ceska M, Buurman WA. Involvement of CD14 in lipopolysaccharide-induced tumour necrosis factor-a, interleukin-6 and interleukin-8 release by human monocytes and alveolar macrophages. J Immunol 1993;150:2885-2891.
-
(1993)
J Immunol
, vol.150
, pp. 2885-2891
-
-
Dentener, M.A.1
Bazil, V.2
Von Asmuth, E.J.U.3
Ceska, M.4
Buurman, W.A.5
-
17
-
-
0028061703
-
Differential regulatory effects of adenosine on cytokine release by activated human monocytes
-
Bouma G, Stad RK, van den Wildenberg FAJM, Buurman WA. Differential regulatory effects of adenosine on cytokine release by activated human monocytes. J Immunol 1994;153:4159-4168.
-
(1994)
J Immunol
, vol.153
, pp. 4159-4168
-
-
Bouma, G.1
Stad, R.K.2
Van Den Wildenberg, F.A.J.M.3
Buurman, W.A.4
-
18
-
-
0026772452
-
Pump-induced haemolysis: Is the constrained vortex pump better or worse than the roller Pump?
-
Horton AM, Butt W. Pump-induced haemolysis: is the constrained vortex pump better or worse than the roller Pump?. Perfusion 1992; 7:103-108.
-
(1992)
Perfusion
, vol.7
, pp. 103-108
-
-
Horton, A.M.1
Butt, W.2
-
19
-
-
0028365541
-
Roller and centrifugal pumps compared in vitro with regard to haemolysis, granulocyte and complement activation
-
Moen O, Fosse E, Braten J, Andersson C, Fagerhol MK, Venge P, Hogasen K, Mollnes TE. Roller and centrifugal pumps compared in vitro with regard to haemolysis, granulocyte and complement activation. Perfusion 1994;9:109-117.
-
(1994)
Perfusion
, vol.9
, pp. 109-117
-
-
Moen, O.1
Fosse, E.2
Braten, J.3
Andersson, C.4
Fagerhol, M.K.5
Venge, P.6
Hogasen, K.7
Mollnes, T.E.8
-
20
-
-
0026183872
-
Routine extracorporeal circulation with a centrifugal or roller pump
-
Jacob HG, Hafner G, Thelemann C, Sturer A, Prellwitz W, Oelert H. Routine extracorporeal circulation with a centrifugal or roller pump. ASAIO Transactions 1991;37:M487-M489.
-
(1991)
ASAIO Transactions
, vol.37
-
-
Jacob, H.G.1
Hafner, G.2
Thelemann, C.3
Sturer, A.4
Prellwitz, W.5
Oelert, H.6
-
21
-
-
0030036575
-
Clinical use of centrifugal pumps and the roller pump in open heart surgery: A comparative evaluation
-
Yoshikai M, Hamada M, Takarebe K, Okazaki Y, Ito T. Clinical use of centrifugal pumps and the roller pump in open heart surgery: a comparative evaluation. Artificial Organs 1996;20:704-706.
-
(1996)
Artificial Organs
, vol.20
, pp. 704-706
-
-
Yoshikai, M.1
Hamada, M.2
Takarebe, K.3
Okazaki, Y.4
Ito, T.5
-
22
-
-
0029049150
-
Centrifugal blood pumps
-
Matheve C. Centrifugal blood pumps. Perfusion 1995;10:141-142.
-
(1995)
Perfusion
, vol.10
, pp. 141-142
-
-
Matheve, C.1
-
23
-
-
0031057423
-
Mechanical white blood cell damage in rotary blood pumps
-
Takami Y, Yamane S, Makinouchi K, Glueck J, Nose Y. Mechanical white blood cell damage in rotary blood pumps. Artificial Organs 1997;21:138-142.
-
(1997)
Artificial Organs
, vol.21
, pp. 138-142
-
-
Takami, Y.1
Yamane, S.2
Makinouchi, K.3
Glueck, J.4
Nose, Y.5
-
25
-
-
0344154671
-
Demonstration of specific C5a receptor on intact human polymorphonuclear leukocytes
-
Chenoweth DE, Hugli TE. Demonstration of specific C5a receptor on intact human polymorphonuclear leukocytes. Proc Natl Acad Sci USA 1978;75:3943-3947.
-
(1978)
Proc Natl Acad Sci USA
, vol.75
, pp. 3943-3947
-
-
Chenoweth, D.E.1
Hugli, T.E.2
-
26
-
-
0019418860
-
Complement activation during cardiopulmonary bypass. Evidence for generation of C3a and C5a anaphylotoxins
-
Chenoweth DE, Cooper SW, Hugli TE, Stewart RW, Blackstone EH, Kirklin JW. Complement activation during cardiopulmonary bypass. Evidence for generation of C3a and C5a anaphylotoxins. N Eng J Med 1981;304:497-503.
-
(1981)
N Eng J Med
, vol.304
, pp. 497-503
-
-
Chenoweth, D.E.1
Cooper, S.W.2
Hugli, T.E.3
Stewart, R.W.4
Blackstone, E.H.5
Kirklin, J.W.6
-
28
-
-
0002520810
-
The postperfusion syndrome: Inflammation and the damaging effects of cardiopulmonary bypass
-
Tinker JH, editor. Philadelphia:Saunders
-
Kirklin JK. The postperfusion syndrome: inflammation and the damaging effects of cardiopulmonary bypass. In: Tinker JH, editor. Cardiopulmonary bypass: current concepts and controversies. Philadelphia:Saunders, 1989:131.
-
(1989)
Cardiopulmonary Bypass: Current Concepts and Controversies
, pp. 131
-
-
Kirklin, J.K.1
-
29
-
-
0023149123
-
Organ dysfunction after cardiopulmonary bypass. A systamic inflammatory reaction initiated by the extracorporeal circuit
-
Westaby S. Organ dysfunction after cardiopulmonary bypass. A systamic inflammatory reaction initiated by the extracorporeal circuit. Intensive Care Med 1987;13:89-95.
-
(1987)
Intensive Care Med
, vol.13
, pp. 89-95
-
-
Westaby, S.1
-
30
-
-
0030933390
-
Haemolysis in different centrifugal pumps
-
Kawahito K, Nose Y. Haemolysis in different centrifugal pumps. Artificial Organs 1997;21:323-326.
-
(1997)
Artificial Organs
, vol.21
, pp. 323-326
-
-
Kawahito, K.1
Nose, Y.2
-
31
-
-
0028889513
-
Haemolysis and heat generation in six different types of centrifugal blood pumps
-
Araki K, Taenaka Y, Masuzawa T, Tatsumi E, Wakisaka Y, Watari M. et al. Haemolysis and heat generation in six different types of centrifugal blood pumps. Artificial Organs 1995;19:928-932.
-
(1995)
Artificial Organs
, vol.19
, pp. 928-932
-
-
Araki, K.1
Taenaka, Y.2
Masuzawa, T.3
Tatsumi, E.4
Wakisaka, Y.5
Watari, M.6
-
32
-
-
0030018137
-
Comparative haemolysis study of clinically available centrifugal pumps
-
Naito K, Suenaga E, Cao ZL, Suda H, Ueno T, Natsuaki M, Itoh T. Comparative haemolysis study of clinically available centrifugal pumps. Artificial Organs 1996;20:560-563.
-
(1996)
Artificial Organs
, vol.20
, pp. 560-563
-
-
Naito, K.1
Suenaga, E.2
Cao, Z.L.3
Suda, H.4
Ueno, T.5
Natsuaki, M.6
Itoh, T.7
|