1
-
-
0029741861
-
Current imaging of the optic disc and retinal nerve fiber layer
-
Burk ROW, Völcker HE: Current imaging of the optic disc and retinal nerve fiber layer. Curr Opin Ophthalmol 1996, 7:99.
-
(1996)
Curr Opin Ophthalmol
, vol.7
, pp. 99
-
-
Burk, R.O.W.1
Völcker, H.E.2
-
2
-
-
0030985497
-
The effect of optic disc size on diagnostic precision with the Heidelberg Retina Tomograph
-
Iester M, Mikelberg FS, Drance SM: The effect of optic disc size on diagnostic precision with the Heidelberg Retina Tomograph. Ophthalmology 1997, 104:545-548. The authors used the Heidelberg Retina Tomograph (HRT) to separate normal subjects from glaucoma patients. They found that the best separation is achieved if a combination of the parameters cup shape measure, height variation in contour, and rim volume is applied. With this parameter combination, a 74% sensitivity and 88% specificity in predicting visual field defects is obtained. It is now used in the printout of the 2.01 version of the HRT to classify a disc either as normal or as glaucomatous.
-
(1997)
Ophthalmology
, vol.104
, pp. 545-548
-
-
Iester, M.1
Mikelberg, F.S.2
Drance, S.M.3
-
3
-
-
0029871582
-
The cumulative normalised rim/disc area ratio curve
-
Bartz-Schmidt KU, Sengersdorf A, Esser P, Walter P, Hilgers RD, Krieglstein GK: The cumulative normalised rim/disc area ratio curve. Graefes Arch Clin Exp Ophthalmol 1996, 234:227-231. The authors introduced the concept of "normalized" cup/disc ratios. Those normalized cup/disc ratios can be used to calculate a ranked segment analysis of each individual disc. The ranked segment analysis is a similar plot as the well-known cumulative defect curve (Bebie curve) in automated perimetry. It can be very helpful in separating normal subjects from glaucoma patients and it is now a printout option of the HRT.
-
(1996)
Graefes Arch Clin Exp Ophthalmol
, vol.234
, pp. 227-231
-
-
Bartz-Schmidt, K.U.1
Sengersdorf, A.2
Esser, P.3
Walter, P.4
Hilgers, R.D.5
Krieglstein, G.K.6
-
4
-
-
0029804465
-
Detection of structural damage from glaucoma with confocal laser image analysis
-
Uchida H, Brigatti L, Caprioli J: Detection of structural damage from glaucoma with confocal laser image analysis. Invest Ophthalmol Vis Sci 1996, 37:2393-2401.
-
(1996)
Invest Ophthalmol Vis Sci
, vol.37
, pp. 2393-2401
-
-
Uchida, H.1
Brigatti, L.2
Caprioli, J.3
-
5
-
-
0029738124
-
Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy
-
Zangwill LM, Vanhorn S, Lima MD, Sample PA, Weinreb RN: Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy. Am J Ophthalmol 1996, 122:520-525.
-
(1996)
Am J Ophthalmol
, vol.122
, pp. 520-525
-
-
Zangwill, L.M.1
Vanhorn, S.2
Lima, M.D.3
Sample, P.A.4
Weinreb, R.N.5
-
6
-
-
0029843530
-
Correlation between peripapillary atrophy and optic nerve damage in normal-tension glaucoma
-
Park KH, Tomita G, Liou SY, Kitazawa Y: Correlation between peripapillary atrophy and optic nerve damage in normal-tension glaucoma. Ophthalmology 1996, 103:1899-1906.
-
(1996)
Ophthalmology
, vol.103
, pp. 1899-1906
-
-
Park, K.H.1
Tomita, G.2
Liou, S.Y.3
Kitazawa, Y.4
-
7
-
-
0344020612
-
Scanning laser tomography detects disease progression in glaucomatous optic neuropathy
-
Hosking SL, Flanagan JG, Donoghue EPO: Scanning laser tomography detects disease progression in glaucomatous optic neuropathy. Invest Ophthalmol Vis Sci 1997, 38(suppl):S828.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Hosking, S.L.1
Flanagan, J.G.2
Donoghue, E.P.O.3
-
8
-
-
33749200983
-
Detection of early glaucomatous change in the optic disc by the Heidelberg Retina Tomograph (HRT) before detectable change in visual fields in a group of ocular hypertensive patients
-
Kamal DS, Viswanathan AC, Garway-Heath DF, Poinoosawmy D, Hitchings RA: Detection of early glaucomatous change in the optic disc by the Heidelberg Retina Tomograph (HRT) before detectable change in visual fields in a group of ocular hypertensive patients. Invest Ophthalmol Vis Sci 1997, 38(suppl):S474.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Kamal, D.S.1
Viswanathan, A.C.2
Garway-Heath, D.F.3
Poinoosawmy, D.4
Hitchings, R.A.5
-
9
-
-
85038529217
-
Verlaufskontrolle der Papillen bei OHT-Patienten mit dem Heidelberg Retina Tomograph
-
Walter S, Meyer JH, Funk J: Verlaufskontrolle der Papillen bei OHT-Patienten mit dem Heidelberg Retina Tomograph. Ophthalmologe 1997, 94(suppl):S30
-
(1997)
Ophthalmologe
, vol.94
, Issue.SUPPL.
-
-
Walter, S.1
Meyer, J.H.2
Funk, J.3
-
10
-
-
0029044003
-
Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes
-
Weinberg RN, Shakiba S; Zangwill L: Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 1995, 119:627-636.
-
(1995)
Am J Ophthalmol
, vol.119
, pp. 627-636
-
-
Weinberg, R.N.1
Shakiba, S.2
Zangwill, L.3
-
11
-
-
15644365582
-
Detection of nerve fiber bundle defects: Scanning laser polarimetry versus conventional nerve fiber photography
-
Mathieu M, Funk J: Detection of nerve fiber bundle defects: scanning laser polarimetry versus conventional nerve fiber photography. Invest Ophthalmol Vis Sci 1996, 37(suppl):S1094.
-
(1996)
Invest Ophthalmol Vis Sci
, vol.37
, Issue.SUPPL.
-
-
Mathieu, M.1
Funk, J.2
-
12
-
-
0027330072
-
Zur Bestimmung der retinalen Nervenfaserschichtdicke in vivo mittels Laser-Polarimetrie
-
Rohrschneider K, Burk ROW, Kruse FE, Völcker HE: Zur Bestimmung der retinalen Nervenfaserschichtdicke in vivo mittels Laser-Polarimetrie. Klin Monatsbl Augenheilkd 1993, 203:200-205.
-
(1993)
Klin Monatsbl Augenheilkd
, vol.203
, pp. 200-205
-
-
Rohrschneider, K.1
Burk, R.O.W.2
Kruse, F.E.3
Völcker, H.E.4
-
13
-
-
0029964849
-
Wertigkeit der Scanning-Laser-Ophthalmoskopie und Polarimetrie gegenüber der Perimetrie zur Beurteilung von glaukomatösen Papillen- Und Nervenfaserschichtveränderungen
-
Stürmer J, Bernasconi P, Caubergh MJ, Frei C, Yanar A, Gloor B: Wertigkeit der Scanning-Laser-Ophthalmoskopie und Polarimetrie gegenüber der Perimetrie zur Beurteilung von glaukomatösen Papillen-und Nervenfaserschichtveränderungen, Ophthalmologe 1996, 93:520-526.
-
(1996)
Ophthalmologe
, vol.93
, pp. 520-526
-
-
Stürmer, J.1
Bernasconi, P.2
Caubergh, M.J.3
Frei, C.4
Yanar, A.5
Gloor, B.6
-
14
-
-
0030253785
-
Läßt sich mittels Laserpolarimetrie durch in-vivo-Messung der retinalen Nervenfaserschichtdicke das Ausmaß des Glaukomschadens quantifizieren
-
Serguhn S, Gramer E: Läßt sich mittels Laserpolarimetrie durch in-vivo-Messung der retinalen Nervenfaserschichtdicke das Ausmaß des Glaukomschadens quantifizieren. Ophthalmologe 1996, 93:527-534.
-
(1996)
Ophthalmologe
, vol.93
, pp. 527-534
-
-
Serguhn, S.1
Gramer, E.2
-
15
-
-
0029800617
-
Reproducibility of the data determined by scanning laser polarimetry
-
Junghardt A, Schmid MK, Schipper I, Wildberger H, Seifert B: Reproducibility of the data determined by scanning laser polarimetry. Graefes Arch Clin Exp Ophthalmol 1996, 234:628-632.
-
(1996)
Graefes Arch Clin Exp Ophthalmol
, vol.234
, pp. 628-632
-
-
Junghardt, A.1
Schmid, M.K.2
Schipper, I.3
Wildberger, H.4
Seifert, B.5
-
16
-
-
0029741678
-
Measurement by nerve fiber analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension
-
Tjon-Fo Sang MJ, Defries J, Lemij HG: Measurement by nerve fiber analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension. Am J Ophthalmol 1996, 122:220-227.
-
(1996)
Am J Ophthalmol
, vol.122
, pp. 220-227
-
-
Tjon-Fo Sang, M.J.1
Defries, J.2
Lemij, H.G.3
-
17
-
-
85038532233
-
Differentiating patients with ocular hypertension or open angle glaucoma from normals by nerve fiber layer thickness measurements with scanning laser polarimetry
-
Choplin NT, Lundy DC, Dreher A: Differentiating patients with ocular hypertension or open angle glaucoma from normals by nerve fiber layer thickness measurements with scanning laser polarimetry. Invest Ophthalmol Vis Sci 1997, 38(suppl):S836.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Choplin, N.T.1
Lundy, D.C.2
Dreher, A.3
-
18
-
-
85038537303
-
Comparing retinal nerve fiber layer thickness measurements with a normal database yields high sensitivity and specificity for detection of glaucoma
-
Rynders MC, Dreher AW, Rennie JE, Reed GC, Yu J, Reiter K: Comparing retinal nerve fiber layer thickness measurements with a normal database yields high sensitivity and specificity for detection of glaucoma. Invest Ophthalmol Vis Sci 1997, 38(suppl):S1147.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Rynders, M.C.1
Dreher, A.W.2
Rennie, J.E.3
Reed, G.C.4
Yu, J.5
Reiter, K.6
-
19
-
-
15644380525
-
Correlation between the nerve fiber layer thickness and the Delphi perimetry in glaucoma patients
-
Garcia-Sanchez J, Garcia Feijoo J, Arias-Puente A: Correlation between the nerve fiber layer thickness and the Delphi perimetry in glaucoma patients. Invest Ophthalmol Vis Sci 1997, 38(suppl):S835.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Garcia-Sanchez, J.1
Garcia Feijoo, J.2
Arias-Puente, A.3
-
20
-
-
85038530447
-
Correlation between nerve fiber analyzer II retardation values and visual field data
-
Chen YY, Xu L, Takahashi Y, Mills RP: Correlation between nerve fiber analyzer II retardation values and visual field data. Invest Ophthalmol Vis Sci 1997, 38(suppl):S837.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Chen, Y.Y.1
Xu, L.2
Takahashi, Y.3
Mills, R.P.4
-
21
-
-
85038530303
-
Spatial contrast sensitivity correlates with polarimetric retardation
-
Takahashi Y, Chen YY, Xu L, Mills RP: Spatial contrast sensitivity correlates with polarimetric retardation. Invest Ophthalmol Vis Sci 1 997, 38(suppl):S836.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Takahashi, Y.1
Chen, Y.Y.2
Xu, L.3
Mills, R.P.4
-
22
-
-
0029851416
-
Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
-
Schuman JS, Pedutkloizman T, Hertzmark E, Hee MR, Wilkins JR, Coker JG, Puliafito CA, Fujimoto JG, Swanson EA: Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology 1996, 103:1889-1898.
-
(1996)
Ophthalmology
, vol.103
, pp. 1889-1898
-
-
Schuman, J.S.1
Pedutkloizman, T.2
Hertzmark, E.3
Hee, M.R.4
Wilkins, J.R.5
Coker, J.G.6
Puliafito, C.A.7
Fujimoto, J.G.8
Swanson, E.A.9
-
23
-
-
85038536843
-
Correlation between perimetric threshold values and RNFL thickness as measured with optical coherence tomography in different retinal areas
-
Brandt L, Heijl A, Bengtsson B: Correlation between perimetric threshold values and RNFL thickness as measured with optical coherence tomography in different retinal areas. Invest Ophthalmol Vis Sci 1997, 38(suppl):S837.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Brandt, L.1
Heijl, A.2
Bengtsson, B.3
-
24
-
-
4243296764
-
The comparison of nerve fiber layer thickness in glaucomatous monkey eyes measured by optical coherence tomography and histomorphometry
-
Huang LN, Schuman JS, P-Kloizman T, Pieroth L. Wang N. Hee MR, Coker JG; Puliafito CA, Fujimoto JG, Swanson EA: The comparison of nerve fiber layer thickness in glaucomatous monkey eyes measured by optical coherence tomography and histomorphometry. Invest Ophthalmol Vis Sci 1997, 38(suppl):S838.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Huang, L.N.1
Schuman, J.S.2
P-Kloizman, T.3
Pieroth, L.4
Wang, N.5
Hee, M.R.6
Coker, J.G.7
Puliafito, C.A.8
Fujimoto, J.G.9
Swanson, E.A.10
-
25
-
-
0029784007
-
A new method for rapid mapping of the retinal thickness at the posterior pole
-
Zeimer R, Shahidi M, Mon M, Zou SH, Asrani S: A new method for rapid mapping of the retinal thickness at the posterior pole. Invest Ophthalmol Vis Sci 1996, 37:1994-2001.
-
(1996)
Invest Ophthalmol Vis Sci
, vol.37
, pp. 1994-2001
-
-
Zeimer, R.1
Shahidi, M.2
Mon, M.3
Zou, S.H.4
Asrani, S.5
-
26
-
-
85038531054
-
Nachweis eines progredienten Glaukomschadens durch "Flickervergleich" von Papillenfotos
-
Funk J: Nachweis eines progredienten Glaukomschadens durch "Flickervergleich" von Papillenfotos. Ophthalmologe 1997, 94(suppl):S16.
-
(1997)
Ophthalmologe
, vol.94
, Issue.SUPPL.
-
-
Funk, J.1
-
27
-
-
0024388766
-
Diagnosis of early glaucoma with flicker comparisons of serial disc photographs
-
Heijl A, Bengtsson B: Diagnosis of early glaucoma with flicker comparisons of serial disc photographs. Invest Ophthalmol Vis Sci 1989, 30:2376-2384.
-
(1989)
Invest Ophthalmol Vis Sci
, vol.30
, pp. 2376-2384
-
-
Heijl, A.1
Bengtsson, B.2
-
28
-
-
0029994157
-
Optic disc hemorrhages and progression of glaucoma
-
Siegner SW, Netland PA: Optic disc hemorrhages and progression of glaucoma. Ophthalmology 1996, 103:1014-1024. The authors screened as many as 33,660 optic disc photographs to study some features of optic disc hemorrhages. In addition, they found that 63% of patients had progressive visual field loss and 79% had progressive disc damage after the hemorrhage (despite medical therapy). This shows that conventional fundus photography is still useful not only in clinical practice but also in scientific studies.
-
(1996)
Ophthalmology
, vol.103
, pp. 1014-1024
-
-
Siegner, S.W.1
Netland, P.A.2
-
29
-
-
85038533716
-
Peripapillary atrophy in glaucoma: A risk factor for progression
-
Uchida H, Ugurlu S, Caprioli J: Peripapillary atrophy in glaucoma: a risk factor for progression. Invest Ophthalmol Vis Sci 1997, 38(suppl):S834.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Uchida, H.1
Ugurlu, S.2
Caprioli, J.3
-
30
-
-
85038533528
-
Changes in nerve fiber layer thickness, pallor and visual fields in ocular hypertensives
-
Demirel S, Takamoto T, Cello KE, Schwartz B, Johson CA: Changes in nerve fiber layer thickness, pallor and visual fields in ocular hypertensives. Invest Ophthalmol Vis Sci 1997, 38(suppl).S835.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, Issue.SUPPL.
-
-
Demirel, S.1
Takamoto, T.2
Cello, K.E.3
Schwartz, B.4
Johson, C.A.5
|