메뉴 건너뛰기




Volumn 53, Issue 5, 1998, Pages 350-352

Long-term follow-up of the Antheor inferior vena cava filter

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD FILTER; CLINICAL ARTICLE; FEMALE; FOLLOW UP; HUMAN; INFERIOR CAVA VEIN; MALE; PRIORITY JOURNAL; PULMONARY ARTERY; PULMONARY ARTERY OCCLUSION; SHEAR STRESS;

EID: 0031745497     PISSN: 00099260     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-9260(98)80007-X     Document Type: Article
Times cited : (11)

References (10)
  • 1
    • 0028593901 scopus 로고
    • Antheor percutaneous endocaval filter. Multicenter evaluation based on 300 cases
    • Midy D Pheline P Baste JC Antheor percutaneous endocaval filter. Multicenter evaluation based on 300 cases Journal Des Malaides Vasculaires 19 1994 308 313
    • (1994) Journal Des Malaides Vasculaires , vol.19 , pp. 308-313
    • Midy, D1    Pheline, P2    Baste, JC3
  • 4
    • 0027923296 scopus 로고
    • Migration of an Antheor filter in the pulmonary artery. A case
    • Vaislic C Clere P Her B Migration of an Antheor filter in the pulmonary artery. A case Presse Medicale 22 1993 717 723
    • (1993) Presse Medicale , vol.22 , pp. 717-723
    • Vaislic, C1    Clere, P2    Her, B3
  • 5
    • 0027239804 scopus 로고
    • A long term follow up of Günther vena caval filters
    • Perry JN Wells IP A long term follow up of Günther vena caval filters Clinical Radiology 48 1993 35 37
    • (1993) Clinical Radiology , vol.48 , pp. 35-37
    • Perry, JN1    Wells, IP2
  • 6
    • 0028244412 scopus 로고
    • Case report. Structural failure of a bird's nest inferior vena caval filter
    • Perry JN Wells IP Case report. Structural failure of a bird's nest inferior vena caval filter Clinical Radiology 49 1994 431 432
    • (1994) Clinical Radiology , vol.49 , pp. 431-432
    • Perry, JN1    Wells, IP2
  • 8
    • 0028020060 scopus 로고
    • In vitro metal fatigue testing of inferior vena cava filters
    • Bejarnson H Yedlicka JW Hunter DW In vitro metal fatigue testing of inferior vena cava filters Investigative Radiology 29 1994 817 821
    • (1994) Investigative Radiology , vol.29 , pp. 817-821
    • Bejarnson, H1    Yedlicka, JW2    Hunter, DW3
  • 9
    • 0028024548 scopus 로고
    • Long term follow up of the Günther basket inferior vena cava filter: Does mechanical instability cause complications?
    • Becker CD Hoogewoud HM Felder P Long term follow up of the Günther basket inferior vena cava filter: Does mechanical instability cause complications? Cardiovascular and Interventional Radiology 17 1994 247 251
    • (1994) Cardiovascular and Interventional Radiology , vol.17 , pp. 247-251
    • Becker, CD1    Hoogewoud, HM2    Felder, P3
  • 10
    • 0028840044 scopus 로고
    • Comparative efficacy and complications of vena caval filters
    • Mohan CR Hballah JJ Sharp WJ Comparative efficacy and complications of vena caval filters Journal of Vascular Surgery 21 1995 235 245
    • (1995) Journal of Vascular Surgery , vol.21 , pp. 235-245
    • Mohan, CR1    Hballah, JJ2    Sharp, WJ3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.