메뉴 건너뛰기




Volumn 50, Issue SUPPL. 1, 1998, Pages 109-119

Instent restenosis: Balloon angioplasty, rotablation or laser therapy

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; ANTITHROMBOCYTIC AGENT; HEPARIN; LOW MOLECULAR WEIGHT HEPARIN; TICLOPIDINE; WARFARIN;

EID: 0031742072     PISSN: 00194832     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (3)

References (55)
  • 1
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fischman D, Leon MB, Baim DS, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994; 331: 496-501
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.1    Leon, M.B.2    Baim, D.S.3
  • 2
    • 0028123099 scopus 로고
    • Acomparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys P, de Jaegere P, Kiemeneij F, et al Acomparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease N Engl J Med 1994; 331: 489-495
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.1    De Jaegere, P.2    Kiemeneij, F.3
  • 3
    • 0030893791 scopus 로고    scopus 로고
    • A comparison of coronary artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery
    • Versaci F, Gaspardone A, Tomai F, et al. A comparison of coronary artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery. N Engl J Med 1997; 336: 817-822
    • (1997) N Engl J Med , vol.336 , pp. 817-822
    • Versaci, F.1    Gaspardone, A.2    Tomai, F.3
  • 4
    • 0028280767 scopus 로고
    • Interseries differences in the restenosis rate of Palmaz-Schatz coronary stent placement
    • Carrozza JP, Kuntz RE, Schatz RA, et al. Interseries differences in the restenosis rate of Palmaz-Schatz coronary stent placement. Cathet Cardiovasc Diagn 1994; 31: 173-178
    • (1994) Cathet Cardiovasc Diagn , vol.31 , pp. 173-178
    • Carrozza, J.P.1    Kuntz, R.E.2    Schatz, R.A.3
  • 5
    • 13344293686 scopus 로고    scopus 로고
    • Three year follow-up after implantation of metallic coronary artery stents
    • Kimura T, Yokoi H, et al. Three year follow-up after implantation of metallic coronary artery stents. N Engl J Med 1996; 334: 561-566
    • (1996) N Engl J Med , vol.334 , pp. 561-566
    • Kimura, T.1    Yokoi, H.2
  • 6
    • 0027446466 scopus 로고
    • Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents
    • Haude M, Erbel R, Lssa H, Meyer J. Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents. J Am Coll Cardiol 1993; 21: 26-34
    • (1993) J Am Coll Cardiol , vol.21 , pp. 26-34
    • Haude, M.1    Erbel, R.2    Lssa, H.3    Meyer, J.4
  • 7
    • 0029837889 scopus 로고    scopus 로고
    • Pattern of instent restenosis: A serial intravascular ultrasound study
    • Hoffman R, Mintz GS, Pichard AD, Kent K, et al. Pattern of instent restenosis: A serial intravascular ultrasound study. Circulation 1996; 94: 1247-1254
    • (1996) Circulation , vol.94 , pp. 1247-1254
    • Hoffman, R.1    Mintz, G.S.2    Pichard, A.D.3    Kent, K.4
  • 8
    • 0031885670 scopus 로고    scopus 로고
    • Instent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia
    • Kornowski R, Hong MK, Tio FO, Bramwell O, et al. Instent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia. J Am Coll Cardiol 1998; 31: 224-230
    • (1998) J Am Coll Cardiol , vol.31 , pp. 224-230
    • Kornowski, R.1    Hong, M.K.2    Tio, F.O.3    Bramwell, O.4
  • 9
    • 0030891415 scopus 로고    scopus 로고
    • Histopathology of in-stent restenosis in patients with peripheral artery disease
    • Kearney M, Pieczek A, Haley L, Losordo DW, et al Histopathology of in-stent restenosis in patients with peripheral artery disease. Circulation 1997; 95: 1998-2002
    • (1997) Circulation , vol.95 , pp. 1998-2002
    • Kearney, M.1    Pieczek, A.2    Haley, L.3    Losordo, D.W.4
  • 10
    • 0002072304 scopus 로고    scopus 로고
    • Long term clinical and quantitative angiographic follow-up after PalmazSchatz stent restenosis
    • Yokoi H, Kimura T, Nakagawa Y, Nosaka H, et al. Long term clinical and quantitative angiographic follow-up after PalmazSchatz stent restenosis. J Am Coll Cardiol 1996; 27 (Suppl A): 224A
    • (1996) J Am Coll Cardiol , vol.27 , Issue.SUPPL. A
    • Yokoi, H.1    Kimura, T.2    Nakagawa, Y.3    Nosaka, H.4
  • 11
    • 0006482539 scopus 로고    scopus 로고
    • Angiographic pattern of instent restenosis after Palmaz-Schatz stent implantation
    • Sharma S, Rajawat Y, Kakarala V, et al. Angiographic pattern of instent restenosis after Palmaz-Schatz stent implantation. J Am Coll Cardiol 1997; 29 (Suppl A): 313A
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Sharma, S.1    Rajawat, Y.2    Kakarala, V.3
  • 12
    • 0001065462 scopus 로고    scopus 로고
    • The predictive value of different IVUS criteria for restenosis after coronary stenting
    • Moussa I, DiMario C, Moses J, et al. The predictive value of different IVUS criteria for restenosis after coronary stenting. J Am Coll Cardiol 1997; 29 (Suppl A): 60A
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Moussa, I.1    DiMario, C.2    Moses, J.3
  • 13
    • 0028269886 scopus 로고
    • Emergency coronary stenting for dissection during PTCA: Angiographic follow-up after stenting and after repeat angioplasty of the stented segment
    • Schomig A, Kastrati A, Dietz R, Rauch B, et al. Emergency coronary stenting for dissection during PTCA: Angiographic follow-up after stenting and after repeat angioplasty of the stented segment. J Am Coll Cardiol 1994; 23: 1053-1060
    • (1994) J Am Coll Cardiol , vol.23 , pp. 1053-1060
    • Schomig, A.1    Kastrati, A.2    Dietz, R.3    Rauch, B.4
  • 14
    • 0000356094 scopus 로고    scopus 로고
    • CRUISE: Can routine IVUS influence stent expansion?
    • Fitzgerald PJ, Hayase M, et al. CRUISE: Can routine IVUS influence stent expansion? J Am Coll Cardiol 1998; 31(Suppl A): 396A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Fitzgerald, P.J.1    Hayase, M.2
  • 15
    • 0032499154 scopus 로고    scopus 로고
    • Instent restenosis: The Washington Hospital Center experience
    • Mintz GS, Hoffman R, et al. Instent restenosis: The Washington Hospital Center experience. Am J Cardiol 1998; 81: 7E-13E
    • (1998) Am J Cardiol , vol.81
    • Mintz, G.S.1    Hoffman, R.2
  • 16
    • 0030876311 scopus 로고    scopus 로고
    • Restenosis rates in diabetic patients
    • Van Belle E, Bauters C, et al. Restenosis rates in diabetic patients. Circulation 1997; 96: 1454-1460
    • (1997) Circulation , vol.96 , pp. 1454-1460
    • Van Belle, E.1    Bauters, C.2
  • 17
    • 0027479588 scopus 로고
    • Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus
    • Carrozza JP, Kuntz RE, Fishman RF, Baim DS. Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus. Ann Int Med 1993; 18: 344-349
    • (1993) Ann Int Med , vol.18 , pp. 344-349
    • Carrozza, J.P.1    Kuntz, R.E.2    Fishman, R.F.3    Baim, D.S.4
  • 18
    • 0028303919 scopus 로고
    • Effect of prior coronary restenosis on the risk of subsequent restenosis after stent placement or directional atherectomy
    • Moscucci M, Piana NP, Kuntz RE, Kugelmass AD, et al. Effect of prior coronary restenosis on the risk of subsequent restenosis after stent placement or directional atherectomy. Am J Cardiol 1994; 73: 1147-1153
    • (1994) Am J Cardiol , vol.73 , pp. 1147-1153
    • Moscucci, M.1    Piana, N.P.2    Kuntz, R.E.3    Kugelmass, A.D.4
  • 19
    • 0028061452 scopus 로고
    • Long term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation
    • Savage MP, Fischman DL, Schatz RA, Tierstein PS, et al. Long term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation. J Am Coll Cardiol 1994; 24: 1207-1212
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1207-1212
    • Savage, M.P.1    Fischman, D.L.2    Schatz, R.A.3    Tierstein, P.S.4
  • 20
    • 0030587229 scopus 로고    scopus 로고
    • Interprocedural interval as a predictor of stent restenosis after previous coronary angioplasty
    • Savage MP, Fischman DL, Rake R, Gebhardt S, et al. Interprocedural interval as a predictor of stent restenosis after previous coronary angioplasty. Am J Cardiol 1996; 78: 683-684
    • (1996) Am J Cardiol , vol.78 , pp. 683-684
    • Savage, M.P.1    Fischman, D.L.2    Rake, R.3    Gebhardt, S.4
  • 21
    • 0031941151 scopus 로고    scopus 로고
    • Plasma activity and insertion/deletion polymorphism of angiotensin 1-converting enzyme: A major risk factor and a marker of risk for coronary stent restenosis
    • Ribichini F, Steffenino G, Dellavalle A, Matullo G, et al. Plasma activity and insertion/deletion polymorphism of angiotensin 1-converting enzyme: A major risk factor and a marker of risk for coronary stent restenosis. Circulation 1998; 97: 147-154
    • (1998) Circulation , vol.97 , pp. 147-154
    • Ribichini, F.1    Steffenino, G.2    Dellavalle, A.3    Matullo, G.4
  • 22
    • 0343852702 scopus 로고    scopus 로고
    • Predictive factors of restenosis after coronary stent placement
    • Kastrati A, Schomig A, Elezi S, Schuhlen H, et al. Predictive factors of restenosis after coronary stent placement. J Am Coll Cardiol 1997; 30: 1428-1436
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1428-1436
    • Kastrati, A.1    Schomig, A.2    Elezi, S.3    Schuhlen, H.4
  • 23
    • 7844235078 scopus 로고    scopus 로고
    • Instent restenosis using newer stent designs
    • Silber S, Seidel S, et al. Instent restenosis using newer stent designs. J Am Coll Cardiol 1998; 31 (Suppl A): 312A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Silber, S.1    Seidel, S.2
  • 24
    • 7844228741 scopus 로고    scopus 로고
    • Coronary stent restenosis: Comparison of six different types of stents
    • Yokoi H, Kimura T, et al. Coronary stent restenosis: Comparison of six different types of stents. J Am Coll Cardiol 1998; 31 (Suppl A): 313A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Yokoi, H.1    Kimura, T.2
  • 25
    • 7844236142 scopus 로고    scopus 로고
    • Comparison of early and late clinical events in coiled vs tubular slotted stents
    • Abizaid AS, Popma JJ, et al. Comparison of early and late clinical events in coiled vs tubular slotted stents. J Am Coll Cardiol 1998; 31 (Suppl A): 314A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Abizaid, A.S.1    Popma, J.J.2
  • 26
    • 0027508929 scopus 로고
    • Management of restenosis within the Palmaz-Schatz coronary stent (the US multicenter experience)
    • Baim DS, Levine MJ, Leon MB, Levine S, et al. Management of restenosis within the Palmaz-Schatz coronary stent (the US multicenter experience) Am J Cardiol 1993; 71: 364-365
    • (1993) Am J Cardiol , vol.71 , pp. 364-365
    • Baim, D.S.1    Levine, M.J.2    Leon, M.B.3    Levine, S.4
  • 27
    • 0030747656 scopus 로고    scopus 로고
    • Long term clinical follow-up after successful repeat percutaneous intervention for stent restentosis
    • Reimers B, Moussa I, Akiyama T, Tucci G, et al. Long term clinical follow-up after successful repeat percutaneous intervention for stent restentosis. J Am Coll Cardiol 1997; 30: 186-192
    • (1997) J Am Coll Cardiol , vol.30 , pp. 186-192
    • Reimers, B.1    Moussa, I.2    Akiyama, T.3    Tucci, G.4
  • 28
    • 0027534711 scopus 로고
    • Mechanisms of restenosis and redilation within coronary stents: Quantitative angiographic assessment
    • Gordon PC, Gibson M, Cohen DJ, Carrozza JP, et al. Mechanisms of restenosis and redilation within coronary stents: Quantitative angiographic assessment. J Am Coll Cardiol 1993; 21: 1166-1174
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1166-1174
    • Gordon, P.C.1    Gibson, M.2    Cohen, D.J.3    Carrozza, J.P.4
  • 29
    • 0030587303 scopus 로고    scopus 로고
    • Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis
    • Mehran R, Mintz GS, Popma JJ, Pichard AD, et al. Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis. Am J Cardiol 1996; 78: 618-622
    • (1996) Am J Cardiol , vol.78 , pp. 618-622
    • Mehran, R.1    Mintz, G.S.2    Popma, J.J.3    Pichard, A.D.4
  • 30
    • 0000596749 scopus 로고    scopus 로고
    • Intracoronary ultrasound assessment of balloon angioplasty in intrastent restenosis
    • Schiele F, Meneveau N, Vuillemenot A, Gupta S, et al. Intracoronary ultrasound assessment of balloon angioplasty in intrastent restenosis. J Am Coll Cardiol 1997; 29: 240A
    • (1997) J Am Coll Cardiol , vol.29
    • Schiele, F.1    Meneveau, N.2    Vuillemenot, A.3    Gupta, S.4
  • 31
    • 0039889998 scopus 로고    scopus 로고
    • Patterns of instent restenosis: Classification and impact on subsequent TLR
    • Mehran R, Abizaid AS, et al. Patterns of instent restenosis: Classification and impact on subsequent TLR. J Am Coll Cardiol 1998; 31 (Suppl A): 141A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Mehran, R.1    Abizaid, A.S.2
  • 32
    • 0038938972 scopus 로고    scopus 로고
    • High speed rotational atherectomy for in-stent restenosis
    • Shawl F. High speed rotational atherectomy for in-stent restenosis. Cathet Cardiovasc Diagn 1996; 38: 116A
    • (1996) Cathet Cardiovasc Diagn , vol.38
    • Shawl, F.1
  • 33
    • 0031026763 scopus 로고    scopus 로고
    • High-speed rotational ablation for instent restenosis
    • Bottner RK, Hardigan KR. High-speed rotational ablation for instent restenosis. Cathet Cardiovasc Diagn 1997; 40: 144-149
    • (1997) Cathet Cardiovasc Diagn , vol.40 , pp. 144-149
    • Bottner, R.K.1    Hardigan, K.R.2
  • 34
    • 0032211063 scopus 로고    scopus 로고
    • Rotational atherectomy for in-stent restenosis: Acute and longterm results of first 100 cases
    • in press
    • Sharma S, Duvvuri S, Dangas G, Kim A, et al. Rotational atherectomy for in-stent restenosis: Acute and longterm results of first 100 cases. J Am Coll Cardiol 1998; 32 (in press)
    • (1998) J Am Coll Cardiol , pp. 32
    • Sharma, S.1    Duvvuri, S.2    Dangas, G.3    Kim, A.4
  • 35
    • 0031880355 scopus 로고    scopus 로고
    • Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis
    • Dauerman HL, Baim DS, Cutlip DE, Sparano AM, et al. Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis. Am J Cardiol 1998; 82: 277-284
    • (1998) Am J Cardiol , vol.82 , pp. 277-284
    • Dauerman, H.L.1    Baim, D.S.2    Cutlip, D.E.3    Sparano, A.M.4
  • 36
    • 0002509435 scopus 로고    scopus 로고
    • Rotational atherectomy for in-stent restenosis: The BARASTER registry
    • Goldberg SL, Shawl F, Buchbinder M, Fortuna R, et al. Rotational atherectomy for in-stent restenosis: The BARASTER registry. Circulation 1997; 96: I-438
    • (1997) Circulation , vol.96
    • Goldberg, S.L.1    Shawl, F.2    Buchbinder, M.3    Fortuna, R.4
  • 37
    • 0039531442 scopus 로고    scopus 로고
    • Randomised trial of rotational atherectomy vs balloon angioplasty for in-stent restenosis (ROSTER)
    • Sharma S, Kini A, Duvvuri S, et al. Randomised trial of rotational atherectomy vs balloon angioplasty for in-stent restenosis (ROSTER). J Am Coll Cardiol 1998; 31 (Suppl A): 142A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Sharma, S.1    Kini, A.2    Duvvuri, S.3
  • 38
    • 0010299469 scopus 로고    scopus 로고
    • Laser angioplasty of within stent restenosis: Results of the LARS surveillance study
    • Hamm CW, Seabra-Gomes R, Bonnier J, Simon R, et al. Laser angioplasty of within stent restenosis: Results of the LARS surveillance study. Eur Heart J 1997; 19: 497A
    • (1997) Eur Heart J , vol.19
    • Hamm, C.W.1    Seabra-Gomes, R.2    Bonnier, J.3    Simon, R.4
  • 39
    • 0030823247 scopus 로고    scopus 로고
    • Treatment of in-stent restenosis with excimer laser angioplasty: Mechanisms and results compared with PTCA alone
    • Mehran R, Mintz GS, Satler LF, Pichard AD, et al. Treatment of in-stent restenosis with excimer laser angioplasty: Mechanisms and results compared with PTCA alone. Circulation 1997; 96: 2183-2189
    • (1997) Circulation , vol.96 , pp. 2183-2189
    • Mehran, R.1    Mintz, G.S.2    Satler, L.F.3    Pichard, A.D.4
  • 40
    • 0027051506 scopus 로고
    • Directional atherectomy for treatment of restenosis within coronary stents: Clinical, angiographic and histologic results
    • Strauss BH, Umans VU, van Suylen RJ, de Feyter P, et al. Directional atherectomy for treatment of restenosis within coronary stents: Clinical, angiographic and histologic results. J Am Coll Cardiol 1992; 20: 1465-1473
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1465-1473
    • Strauss, B.H.1    Umans, V.U.2    Van Suylen, R.J.3    De Feyter, P.4
  • 41
    • 0002642849 scopus 로고    scopus 로고
    • Directional coronary atherectomy is superior to PTCA for the treatment of PalmazSchatz stent restenosis
    • Pathan A, Butte A, Hartell L, Ferrell L, et al. Directional coronary atherectomy is superior to PTCA for the treatment of PalmazSchatz stent restenosis. J Am Coll Cardiol 1997; 29: 68A
    • (1997) J Am Coll Cardiol , vol.29
    • Pathan, A.1    Butte, A.2    Hartell, L.3    Ferrell, L.4
  • 43
    • 0031005933 scopus 로고    scopus 로고
    • Catheter based radiotherapy to inhibit restenosis after coronary stenting
    • Tierstein P, Massullo U, Jani S, et al. Catheter based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med 1997; 336: 1697-1703
    • (1997) N Engl J Med , vol.336 , pp. 1697-1703
    • Tierstein, P.1    Massullo, U.2    Jani, S.3
  • 44
    • 0342981071 scopus 로고    scopus 로고
    • Restenosis after coronary stent placement and randomisation to a 4-week combined antiplatelet or anticoagulant therapy: Six-month angiographic follow-up of the intracoronary stenting and antithrombotic regimen (ISAR) trial
    • Kastrati A, Schuhlen H, Hausleiter J, Walter H, et al. Restenosis after coronary stent placement and randomisation to a 4-week combined antiplatelet or anticoagulant therapy: Six-month angiographic follow-up of the intracoronary stenting and antithrombotic regimen (ISAR) trial. Circulation 1997; 96: 462-467
    • (1997) Circulation , vol.96 , pp. 462-467
    • Kastrati, A.1    Schuhlen, H.2    Hausleiter, J.3    Walter, H.4
  • 45
    • 0000173824 scopus 로고    scopus 로고
    • Initial and six-month outcome of Palmaz-Schatz stent implantation: STRESS/ BENESTENT equivalent vs nonequivalent lesions
    • Sawada Y, Nokasa H, Kimura T, et al Initial and six-month outcome of Palmaz-Schatz stent implantation: STRESS/ BENESTENT equivalent vs nonequivalent lesions. J Am Coll Cardiol 1996; 27 (Suppl A); 252A
    • (1996) J Am Coll Cardiol , vol.27 , Issue.SUPPL. A
    • Sawada, Y.1    Nokasa, H.2    Kimura, T.3
  • 46
    • 0000256821 scopus 로고    scopus 로고
    • Outcome of stenting in the real world
    • Schwartz L, Blew B. Outcome of stenting in the real world. J Am Coll Cardiol 1997; 29 (Suppl A): 496A
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Schwartz, L.1    Blew, B.2
  • 47
    • 0001803713 scopus 로고    scopus 로고
    • Real-life stenting: A comparison of target vessel revascularization in BENESTENT-STRESS lesions to non-BENESTENT-STRESS lesions
    • Tilli F, Aliabadi D, Kinn J, Kaplan B, et al. Real-life stenting: A comparison of target vessel revascularization in BENESTENT-STRESS lesions to non-BENESTENT-STRESS lesions. Circulation 1996; 94 (Suppl I): I-332
    • (1996) Circulation , vol.94 , Issue.1 SUPPL.
    • Tilli, F.1    Aliabadi, D.2    Kinn, J.3    Kaplan, B.4
  • 48
    • 0000291067 scopus 로고    scopus 로고
    • Are STRESS results generalizable? The NACI-PSS experience
    • George C, Kennard E, Holubkov R, Detre K, et al. Are STRESS results generalizable? The NACI-PSS experience. J Am Coll Cardiol 1997; 29 (Suppl A): 495A
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • George, C.1    Kennard, E.2    Holubkov, R.3    Detre, K.4
  • 49
    • 0028303972 scopus 로고
    • Balloon angioplasty for treatment of in-stent restenosis: Feasibility, safety, and efficacy
    • Macander PJ, Roubin GS, Agrawal SK, Cannon AD, et al. Balloon angioplasty for treatment of in-stent restenosis: Feasibility, safety, and efficacy. Cathet Cardiovasc Diagn 1994; 32: 125-131
    • (1994) Cathet Cardiovasc Diagn , vol.32 , pp. 125-131
    • Macander, P.J.1    Roubin, G.S.2    Agrawal, S.K.3    Cannon, A.D.4
  • 50
    • 7844226584 scopus 로고    scopus 로고
    • Restenosis after stent implantation: Excimer laser, rotational atherectomy or conventional balloon angioplasty?
    • Lauer B, Schmidt E, Ambrosch H, et al. Restenosis after stent implantation: Excimer laser, rotational atherectomy or conventional balloon angioplasty? Eur Heart J 1998; 19 (Suppl): 115
    • (1998) Eur Heart J , vol.19 , Issue.SUPPL. , pp. 115
    • Lauer, B.1    Schmidt, E.2    Ambrosch, H.3
  • 51
    • 4243603550 scopus 로고    scopus 로고
    • Laser angioplasty of restenotic and occluded stents
    • Koster R, Hamm C, Koschyk DH, Terres W, et al. Laser angioplasty of restenotic and occluded stents. Eur Heart J 1996; 17: 308
    • (1996) Eur Heart J , vol.17 , pp. 308
    • Koster, R.1    Hamm, C.2    Koschyk, D.H.3    Terres, W.4
  • 52
    • 7844246122 scopus 로고    scopus 로고
    • Angiographic long-term results of coronary rotational atherectomy for treatment of diffuse in-stent restenosis are dependent on the length of the initial in-stent restenosis
    • vom Dahl J, Klues HG, Radke P, Haager P, et al. Angiographic long-term results of coronary rotational atherectomy for treatment of diffuse in-stent restenosis are dependent on the length of the initial in-stent restenosis. Eur Heart J 1998; 19 (Suppl): 114
    • (1998) Eur Heart J , vol.19 , Issue.SUPPL. , pp. 114
    • Vom Dahl, J.1    Klues, H.G.2    Radke, P.3    Haager, P.4
  • 53
    • 0001803774 scopus 로고    scopus 로고
    • Rotational atherectomy followed by balloon angioplasty for treatment of intrastent restenosis: A pilot study with quantitative angiography and intracoronary ultrasound
    • Schiele F, Meneveau N, Vuillemenot A, Gupta S, et al. Rotational atherectomy followed by balloon angioplasty for treatment of intrastent restenosis: A pilot study with quantitative angiography and intracoronary ultrasound J Am Coll Cardiol 1997; 29 (Suppl A): 498A
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Schiele, F.1    Meneveau, N.2    Vuillemenot, A.3    Gupta, S.4
  • 54
    • 4243296071 scopus 로고    scopus 로고
    • PTCA, directional and rotational coronary atherectomy in the management of Palmaz-Schatz instent restenosis
    • Mahdi NA, Leon MB, Mikulic M, Pathan A, et al. PTCA, directional and rotational coronary atherectomy in the management of Palmaz-Schatz instent restenosis. J Am Coll Cardiol 1998; 31 (Suppl A): 275A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Mahdi, N.A.1    Leon, M.B.2    Mikulic, M.3    Pathan, A.4
  • 55
    • 0001655185 scopus 로고    scopus 로고
    • Rotational ablation with adjunctive low pressure balloon dilatation in diffuse instent restenosis: Immediate and follow-up results
    • Buttner HJ, Muller C, Hodgson J, Frey AW, et al. Rotational ablation with adjunctive low pressure balloon dilatation in diffuse instent restenosis: Immediate and follow-up results. J Am Coll Cardiol 1998, 31 (Suppl A): 141A
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL. A
    • Buttner, H.J.1    Muller, C.2    Hodgson, J.3    Frey, A.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.