메뉴 건너뛰기




Volumn 43, Issue 11, 1998, Pages 3171-3181

Correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM; COBALT 60; GRAPHITE; IRIDIUM 192; POLY(METHYL METHACRYLATE); POLYSTYRENE;

EID: 0031741039     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/43/11/001     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 0023018876 scopus 로고
    • Chamber-dependent wall correction factors in dosimetry
    • Andreo P, Nahum A and Brahme A 1986 Chamber-dependent wall correction factors in dosimetry Phys. Med. Biol. 31 1189-99
    • (1986) Phys. Med. Biol. , vol.31 , pp. 1189-1199
    • Andreo, P.1    Nahum, A.2    Brahme, A.3
  • 2
    • 0025304663 scopus 로고
    • An analytic theory of the point-source non-uniformity correction factor for thick-walled ionisation chambers in photon beams
    • Bielajew A F 1990 An analytic theory of the point-source non-uniformity correction factor for thick-walled ionisation chambers in photon beams Phys. Med. Biol. 35 517-38
    • (1990) Phys. Med. Biol. , vol.35 , pp. 517-538
    • Bielajew, A.F.1
  • 4
    • 42549173386 scopus 로고
    • Exposure dose measurements in megavoltage therapy
    • Greene D, Massey J B and Meredith W J 1961 Exposure dose measurements in megavoltage therapy Phys. Med. Biol. 6 551-60
    • (1961) Phys. Med. Biol. , vol.6 , pp. 551-560
    • Greene, D.1    Massey, J.B.2    Meredith, W.J.3
  • 5
    • 0003523755 scopus 로고
    • Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest
    • Gaithersburg, MD: National Institute of Standards and Technology
    • Hubbell J H and Seltzer S M 1995 Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest NIST Report 5632 (Gaithersburg, MD: National Institute of Standards and Technology)
    • (1995) NIST Report 5632
    • Hubbell, J.H.1    Seltzer, S.M.2
  • 6
    • 0003484991 scopus 로고
    • Absorbed dose determination in photon and electron beams: An international code of practice
    • Vienna: IAEA
    • International Atomic Energy Agency (IAEA) 1987 Absorbed dose determination in photon and electron beams: an international code of practice Technical Report Series 277 (Vienna: IAEA)
    • (1987) Technical Report Series , vol.277
  • 7
    • 0003464633 scopus 로고
    • Radiation dosimetry: X-rays and gamma-rays with maximum photon energies between 0.6 and 50 MeV
    • Washington, DC: ICRU
    • International Commission on Radiation Units and Measurements (ICRU) 1969 Radiation dosimetry: x-rays and gamma-rays with maximum photon energies between 0.6 and 50 MeV ICRU Report 14 (Washington, DC: ICRU)
    • (1969) ICRU Report , vol.14
  • 8
    • 0010637211 scopus 로고
    • Measurement of absorbed dose in a phantom irradiated by a single beam of x or gamma rays
    • Washington, DC: ICRU
    • _ 1973 Measurement of absorbed dose in a phantom irradiated by a single beam of x or gamma rays ICRU Report 23 (Washington, DC: ICRU)
    • (1973) ICRU Report , vol.23
  • 9
    • 71749085545 scopus 로고
    • Stopping powers for electrons and positrons
    • Bethesda, MD: ICRU
    • _ 1984 Stopping powers for electrons and positrons ICRU Report 37 (Bethesda, MD: ICRU)
    • (1984) ICRU Report , vol.37
  • 11
    • 0001882717 scopus 로고
    • Effect of finite size of ionization chambers on measurement of small photon sources
    • Kondo S and Randolph M L 1960 Effect of finite size of ionization chambers on measurement of small photon sources Radiat. Res. 13 1032-40
    • (1960) Radiat. Res. , vol.13 , pp. 1032-1040
    • Kondo, S.1    Randolph, M.L.2
  • 12
    • 0021043263 scopus 로고
    • Measured influence of the central electrode diameter and material on the response of a graphite ionization chamber to cobalt-60 gamma rays
    • Kristensen M 1983 Measured influence of the central electrode diameter and material on the response of a graphite ionization chamber to cobalt-60 gamma rays Phys. Med. Biol. 28 1269-78
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1269-1278
    • Kristensen, M.1
  • 13
    • 0027535624 scopus 로고
    • Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams
    • Ma C and Nahum A 1993 Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams Phys. Med. Biol. 38 267-90
    • (1993) Phys. Med. Biol. , vol.38 , pp. 267-290
    • Ma, C.1    Nahum, A.2
  • 14
    • 0028798472 scopus 로고
    • Calculation of ion chamber displacement effect corrections for medium-energy x-ray dosimetry
    • _ 1995 Calculation of ion chamber displacement effect corrections for medium-energy x-ray dosimetry Phys. Med. Biol. 40 45-62
    • (1995) Phys. Med. Biol. , vol.40 , pp. 45-62
  • 16
    • 84907107583 scopus 로고
    • Charge build-up effects in insulating phantom materials
    • Mattsson L O and Svensson H 1984 Charge build-up effects in insulating phantom materials Acta Radiat. Oncol. 23 393-9
    • (1984) Acta Radiat. Oncol. , vol.23 , pp. 393-399
    • Mattsson, L.O.1    Svensson, H.2
  • 19
    • 0021264448 scopus 로고
    • Charge storage effect on dose in insulating phantoms irradiated with electrons
    • Thwaites D I 1984 Charge storage effect on dose in insulating phantoms irradiated with electrons Phys. Med. Biol. 29 1153-6
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1153-1156
    • Thwaites, D.I.1
  • 20
    • 1842287952 scopus 로고    scopus 로고
    • Fluence non-uniformity effects in air kerma determination around brachytherapy sources
    • Tölli H, Bielajew A F, Mattsson O, Sernbo G and Johansson K-A 1997 Fluence non-uniformity effects in air kerma determination around brachytherapy sources Phys. Med. Biol. 42 1301-18
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1301-1318
    • Tölli, H.1    Bielajew, A.F.2    Mattsson, O.3    Sernbo, G.4    Johansson, K.-A.5
  • 21
    • 0027375259 scopus 로고
    • Quality assurance in brachytherapy: Principles for ionization chamber measurement of absorbed dose close to brachytherapy sources
    • Tölli H and Johansson K-A 1993a Quality assurance in brachytherapy: principles for ionization chamber measurement of absorbed dose close to brachytherapy sources Phys. Med. Biol. 38 1475-83
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1475-1483
    • Tölli, H.1    Johansson, K.-A.2
  • 22
    • 0027493188 scopus 로고
    • 192Ir brachytherapy sources
    • 192Ir brachytherapy sources Phys. Med. Biol. 38 1485-92
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1485-1492
  • 23
    • 0018826425 scopus 로고
    • Effective measuring point ion chambers for photon dosimetry in phantoms
    • Zoetelief J, Engels A C and Broerse J J 1980 Effective measuring point ion chambers for photon dosimetry in phantoms Br. J. Radiol. 53 580-3
    • (1980) Br. J. Radiol. , vol.53 , pp. 580-583
    • Zoetelief, J.1    Engels, A.C.2    Broerse, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.