메뉴 건너뛰기




Volumn 25, Issue 11, 1998, Pages 1502-1510

Comparative myocardial uptake of technetium-99m sestamibi and technetium-99m tetrofosmin one hour after stress injection

Author keywords

Comparison; Myocardial uptake; Technetium 99m sestamibi; Technetium 99m tetrofosmin

Indexed keywords

DIPYRIDAMOLE; METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M; RADIOPHARMACEUTICAL AGENT; TETROFOSMIN TC 99M;

EID: 0031740417     PISSN: 03406997     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002590050328     Document Type: Article
Times cited : (8)

References (47)
  • 1
    • 0027504581 scopus 로고
    • Separate acquisition rest 201-thallium/stress technetium-99m-sestamibi dual-isotope myocardial perfusion single-photon emission tomography: A clinical validation study
    • Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest 201-thallium/stress technetium-99m-sestamibi dual-isotope myocardial perfusion single-photon emission tomography: a clinical validation study. J Am Coll Cardiol 1993; 22: 1455-1464.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1455-1464
    • Berman, D.S.1    Kiat, H.2    Friedman, J.D.3
  • 2
    • 0028206634 scopus 로고
    • Dual-isotope myocardial imaging: Feasibility, advantages and limitations. Preliminary report on 231 consecutive patients
    • Weinmann P, Foult JM, Le Guludec D, et al. Dual-isotope myocardial imaging: feasibility, advantages and limitations. Preliminary report on 231 consecutive patients. Eur J Nucl Med 1994; 21:212-215.
    • (1994) Eur J Nucl Med , vol.21 , pp. 212-215
    • Weinmann, P.1    Foult, J.M.2    Le Guludec, D.3
  • 4
    • 0024457885 scopus 로고
    • 99mTc-methoxy-isobutyl-isonitrile (MIBI): Regional and temporal activity curve analysis
    • 99mTc-methoxy-isobutyl-isonitrile (MIBI): regional and temporal activity curve analysis. Nucl Med Commun 1989; 10:723-732.
    • (1989) Nucl Med Commun , vol.10 , pp. 723-732
    • Grucker, D.1    Florentz, P.2    Oswald, T.3    Chambron, J.4
  • 5
    • 0026345219 scopus 로고
    • Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms
    • Faber TL, Akers MS, Peshock RM, Corbett JR. Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms. J Nucl Med 1991; 32: 2311-2317.
    • (1991) J Nucl Med , vol.32 , pp. 2311-2317
    • Faber, T.L.1    Akers, M.S.2    Peshock, R.M.3    Corbett, J.R.4
  • 7
    • 0027502249 scopus 로고
    • Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities
    • Mannting F, Morgan-Mannting MG. Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities. J Nucl Med 1993; 34:601-608.
    • (1993) J Nucl Med , vol.34 , pp. 601-608
    • Mannting, F.1    Morgan-Mannting, M.G.2
  • 8
    • 0027442739 scopus 로고
    • Left ventricular ejection fraction from gated technetium-99m-sestamibi SPECT
    • DePuey EG, Nichols KN, Dobrinsky C. Left ventricular ejection fraction from gated technetium-99m-sestamibi SPECT. J Nucl Med 1993; 34:1871-1876.
    • (1993) J Nucl Med , vol.34 , pp. 1871-1876
    • DePuey, E.G.1    Nichols, K.N.2    Dobrinsky, C.3
  • 9
    • 0028222783 scopus 로고
    • Gated technetium-99m-sestamibi for simultaneous assessment of stress myocardial perfusion, post-exercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy
    • Chua T, Kiat H, Germano G, et al. Gated technetium-99m-sestamibi for simultaneous assessment of stress myocardial perfusion, post-exercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy. J Am Coll Cardiol 1994; 23: 1107-1114.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 1107-1114
    • Chua, T.1    Kiat, H.2    Germano, G.3
  • 10
    • 0028337464 scopus 로고
    • Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: A simulation study based on canine and patient data
    • Cooke CD, Garcia EV, Cullom SJ, Faber TL, Pettigrew RI. Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data. J Nucl Med 1994; 35: 1185-1192.
    • (1994) J Nucl Med , vol.35 , pp. 1185-1192
    • Cooke, C.D.1    Garcia, E.V.2    Cullom, S.J.3    Faber, T.L.4    Pettigrew, R.I.5
  • 11
    • 0027957062 scopus 로고
    • Quantitative myocardial perfusion single-photon emission computed tomographic imaging: Quo vadis? (Where do we go from here?)
    • Garcia EV. Quantitative myocardial perfusion single-photon emission computed tomographic imaging: Quo vadis? (Where do we go from here?). J Nucl Cardiol 1994; 1:83-93.
    • (1994) J Nucl Cardiol , vol.1 , pp. 83-93
    • Garcia, E.V.1
  • 12
    • 0028010907 scopus 로고
    • Modelling the integration of myocardial regional perfusion and function
    • Goris ML, Thompson C, Malone LJ, Franken PR. Modelling the integration of myocardial regional perfusion and function. Nucl Med Commun 1994; 15:9-20.
    • (1994) Nucl Med Commun , vol.15 , pp. 9-20
    • Goris, M.L.1    Thompson, C.2    Malone, L.J.3    Franken, P.R.4
  • 13
    • 0029069659 scopus 로고
    • Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artefact
    • DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artefact. J Nucl Med 1995; 36:952-955.
    • (1995) J Nucl Med , vol.36 , pp. 952-955
    • DePuey, E.G.1    Rozanski, A.2
  • 14
    • 0028807605 scopus 로고
    • Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
    • Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138-2147.
    • (1995) J Nucl Med , vol.36 , pp. 2138-2147
    • Germano, G.1    Kiat, H.2    Kavanagh, P.B.3
  • 17
    • 0030071191 scopus 로고    scopus 로고
    • Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography
    • Williams KA, Taillon LA. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. J Am Coll Cardiol 1996; 27:173-181.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 173-181
    • Williams, K.A.1    Taillon, L.A.2
  • 18
    • 0030462552 scopus 로고    scopus 로고
    • Left ventricular ejection fraction from gated SPET myocardial perfusion studies: A method based on the radial distribution of count rate density across the myocardial wall
    • Everaert H, Franken PR, Flamen P, Goris M, Momen A, Bossuyt A. Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on the radial distribution of count rate density across the myocardial wall. Eur J Nucl Med 1996; 23:1628-1633.
    • (1996) Eur J Nucl Med , vol.23 , pp. 1628-1633
    • Everaert, H.1    Franken, P.R.2    Flamen, P.3    Goris, M.4    Momen, A.5    Bossuyt, A.6
  • 19
    • 10544252276 scopus 로고    scopus 로고
    • Prolonged impairment of regional contractile function after resolution of exercise-induced angina. Evidence of myocardial stunning in patients with coronary artery disease
    • Ambrosio G, Betocchi S, Pace L, et al. Prolonged impairment of regional contractile function after resolution of exercise-induced angina. Evidence of myocardial stunning in patients with coronary artery disease. Circulation 1996; 94:2455-2464.
    • (1996) Circulation , vol.94 , pp. 2455-2464
    • Ambrosio, G.1    Betocchi, S.2    Pace, L.3
  • 20
    • 0026042652 scopus 로고
    • Technetium-99m-sestamibi myocardial imaging in detection of coronary artery disease: Comparison between initial (1-hour) and delayed (3-hour) postexercise images
    • Taillefer R, Primeau M, Costi P, Lambert R, Léveillé J, Latour Y. Technetium-99m-sestamibi myocardial imaging in detection of coronary artery disease: comparison between initial (1-hour) and delayed (3-hour) postexercise images. J Nucl Med 1991; 32:1961-1965.
    • (1991) J Nucl Med , vol.32 , pp. 1961-1965
    • Taillefer, R.1    Primeau, M.2    Costi, P.3    Lambert, R.4    Léveillé, J.5    Latour, Y.6
  • 21
    • 0025346030 scopus 로고
    • Myocardial clearance of Tc-99 m hexakis-2-methoxypropyl isonotrile (MIBI) in patients with coronary artery disease
    • Franceschi M, Guimond J, Zimmerman RE, et al. Myocardial clearance of Tc-99 m hexakis-2-methoxypropyl isonotrile (MIBI) in patients with coronary artery disease. Clin Nucl Med 1990; 15:307-312.
    • (1990) Clin Nucl Med , vol.15 , pp. 307-312
    • Franceschi, M.1    Guimond, J.2    Zimmerman, R.E.3
  • 22
    • 0028897438 scopus 로고
    • Washout and redistribution between immediate and two-hour myocardial images using technetium-99m sestamibi
    • Richter WS, Cordes M, Calder D, Eichstaedt H, Felix R. Washout and redistribution between immediate and two-hour myocardial images using technetium-99m sestamibi. Eur J Nucl Med 1995; 22:49-55.
    • (1995) Eur J Nucl Med , vol.22 , pp. 49-55
    • Richter, W.S.1    Cordes, M.2    Calder, D.3    Eichstaedt, H.4    Felix, R.5
  • 23
    • 0028825635 scopus 로고
    • Technetium-99m-tetrofosmin in dipyridamole-stress myocardial SPECT imaging: Intraindividual comparison with technetium-99m-sestamibi
    • Flamen P, Bossuyt A, Franken PR. Technetium-99m-tetrofosmin in dipyridamole-stress myocardial SPECT imaging: intraindividual comparison with technetium-99m-sestamibi. J Nucl Med 1995; 36:2009-2015.
    • (1995) J Nucl Med , vol.36 , pp. 2009-2015
    • Flamen, P.1    Bossuyt, A.2    Franken, P.R.3
  • 24
    • 0029974112 scopus 로고    scopus 로고
    • Quantitative comparison of planar and SPECT normal data files of thallium-201, technetium-99m-sestamibi, technetium-99m-tetrofosmin and technetium-99m-furifosmin
    • Naruse H, Daher E, Sinusas A, et al. Quantitative comparison of planar and SPECT normal data files of thallium-201, technetium-99m-sestamibi, technetium-99m-tetrofosmin and technetium-99m-furifosmin. J Nucl Med 1996; 37:1783-1788.
    • (1996) J Nucl Med , vol.37 , pp. 1783-1788
    • Naruse, H.1    Daher, E.2    Sinusas, A.3
  • 26
    • 1842288027 scopus 로고    scopus 로고
    • Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease
    • Munch G, Neverve J, Matsunari I, Schröter G, Schwaiger M. Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease. J Nucl Med 1997; 38:428-432.
    • (1997) J Nucl Med , vol.38 , pp. 428-432
    • Munch, G.1    Neverve, J.2    Matsunari, I.3    Schröter, G.4    Schwaiger, M.5
  • 27
    • 0030903467 scopus 로고    scopus 로고
    • Technetium-99m sestamibi and tetrofosmin myocardial single-photon emission tomography: Can we use the same reference data base ?
    • Widding A, Hesse B, Gadsboll N. Technetium-99m sestamibi and tetrofosmin myocardial single-photon emission tomography: can we use the same reference data base ? Eur J Nucl Med 1997; 24:42-45.
    • (1997) Eur J Nucl Med , vol.24 , pp. 42-45
    • Widding, A.1    Hesse, B.2    Gadsboll, N.3
  • 28
    • 15644381564 scopus 로고    scopus 로고
    • Tomoscintigraphie myocardique séquentielle double isotope avec synchronisation à l'ECG: Justification théorique et réalisation pratique
    • Gremillet E, Champailler A. Tomoscintigraphie myocardique séquentielle double isotope avec synchronisation à l'ECG: justification théorique et réalisation pratique. Médecine Nucléaire 1997; 21:137-141.
    • (1997) Médecine Nucléaire , vol.21 , pp. 137-141
    • Gremillet, E.1    Champailler, A.2
  • 30
    • 0030912582 scopus 로고    scopus 로고
    • Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT
    • Germano G, Erel J, Kiat H, Kvanagh PB, Berman DS. Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT. J Nucl Med 1997; 38:749-754.
    • (1997) J Nucl Med , vol.38 , pp. 749-754
    • Germano, G.1    Erel, J.2    Kiat, H.3    Kvanagh, P.B.4    Berman, D.S.5
  • 31
    • 0030905195 scopus 로고    scopus 로고
    • Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT
    • Maunoury C, Chen CC, Chua KB, Thompson CJ. Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT. J Nucl Med 1997; 38:958-961.
    • (1997) J Nucl Med , vol.38 , pp. 958-961
    • Maunoury, C.1    Chen, C.C.2    Chua, K.B.3    Thompson, C.J.4
  • 32
    • 0025449462 scopus 로고
    • Effects of myocardial wall thickness on SPECT quantification
    • Galt JR, Garcia EV, Robbins W. Effects of myocardial wall thickness on SPECT quantification. IEEE Trans Med Imaging 1990; 9:144-150.
    • (1990) IEEE Trans Med Imaging , vol.9 , pp. 144-150
    • Galt, J.R.1    Garcia, E.V.2    Robbins, W.3
  • 33
    • 0031039039 scopus 로고    scopus 로고
    • A $hybrid" method for measuring myocardial wall thickening from gated PET/SPECT images
    • Buvat I, Bartlett ML, Kitsiou AN, Dilsizian V, Bacharach SL. A $hybrid" method for measuring myocardial wall thickening from gated PET/SPECT images. J Nucl Med 1997; 38: 324-329.
    • (1997) J Nucl Med , vol.38 , pp. 324-329
    • Buvat, I.1    Bartlett, M.L.2    Kitsiou, A.N.3    Dilsizian, V.4    Bacharach, S.L.5
  • 34
    • 0028147652 scopus 로고
    • A quantitative phantom analysis of artefacts due to hepatic activity in technetium-99m myocardial perfusion SPECT studies
    • Germano G, Chua T, Kiat H, Areeda JS, Berman DS. A quantitative phantom analysis of artefacts due to hepatic activity in technetium-99m myocardial perfusion SPECT studies. J Nucl Med 1994; 35:356-359.
    • (1994) J Nucl Med , vol.35 , pp. 356-359
    • Germano, G.1    Chua, T.2    Kiat, H.3    Areeda, J.S.4    Berman, D.S.5
  • 36
    • 0024582126 scopus 로고
    • Technetium-99m hexakis 2-methoxyisobutyl isonitrile: Human distribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging
    • Wackers FJ, Berman DS, Maddahi J, et al. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human distribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 1989; 30: 301-311.
    • (1989) J Nucl Med , vol.30 , pp. 301-311
    • Wackers, F.J.1    Berman, D.S.2    Maddahi, J.3
  • 37
    • 0024407733 scopus 로고
    • Biodistribution of Tc-99m methoxy-isobutyl-isonitrile (MIBI) in humans
    • Savi A, Gerundini P, Zoli P, et al. Biodistribution of Tc-99m methoxy-isobutyl-isonitrile (MIBI) in humans. Eur J Nucl Med 1989; 15:597-600.
    • (1989) Eur J Nucl Med , vol.15 , pp. 597-600
    • Savi, A.1    Gerundini, P.2    Zoli, P.3
  • 38
    • 0025001957 scopus 로고
    • Technetium-99m sestamibi myocardial imaging same day rest-stress studies and dipyridamole
    • Taillefer R. Technetium-99m sestamibi myocardial imaging same day rest-stress studies and dipyridamole. Am J Cardiol 1990; 66:80E-84E.
    • (1990) Am J Cardiol , vol.66
    • Taillefer, R.1
  • 39
    • 0027166184 scopus 로고
    • Biokinetics of technetium-99m-tetrofosmin: Myocardial perfusion agent: implications for a one-day imaging protocol
    • Jain D, Wackers FJT, Mattera J, McMahon M, Sinusas AJ, Zaret BL. Biokinetics of technetium-99m-tetrofosmin: myocardial perfusion agent: implications for a one-day imaging protocol. J Nucl Med 1993; 34:1254-1259.
    • (1993) J Nucl Med , vol.34 , pp. 1254-1259
    • Jain, D.1    Wackers, F.J.T.2    Mattera, J.3    McMahon, M.4    Sinusas, A.J.5    Zaret, B.L.6
  • 40
    • 0027514338 scopus 로고
    • Technetium-99m-1,2-bis[bis(2-ethoxyethyl)phosphino]ethane: Human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent
    • Higley B, Smith FW, Smith T, et al. Technetium-99m-1,2-bis[bis(2-ethoxyethyl)phosphino]ethane: human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent. J Nucl Med 1993; 34:30-38.
    • (1993) J Nucl Med , vol.34 , pp. 30-38
    • Higley, B.1    Smith, F.W.2    Smith, T.3
  • 42
    • 0029794332 scopus 로고    scopus 로고
    • Early and delayed technetium-99m-tetrofosmin myocardial SPECT compared in normal volunteers
    • Matsunari I, Tanishima Y, Taki J, et al. Early and delayed technetium-99m-tetrofosmin myocardial SPECT compared in normal volunteers. J Nucl Med 1996; 37:1622-1626.
    • (1996) J Nucl Med , vol.37 , pp. 1622-1626
    • Matsunari, I.1    Tanishima, Y.2    Taki, J.3
  • 43
    • 0027509425 scopus 로고
    • Assessment of myocardial perfusion defect size after early and delayed SPECT imaging with technetium-99m-hexakis 2-methoxyisobutyl isonitrile after stress
    • Villanueva-Meyer J, Mena I, Diggles L, Narahara KA. Assessment of myocardial perfusion defect size after early and delayed SPECT imaging with technetium-99m-hexakis 2-methoxyisobutyl isonitrile after stress. J Nucl Med 1993; 34: 187-192.
    • (1993) J Nucl Med , vol.34 , pp. 187-192
    • Villanueva-Meyer, J.1    Mena, I.2    Diggles, L.3    Narahara, K.A.4
  • 45
    • 0028789666 scopus 로고
    • Myocardial viability index in chronic artery disease: Technetium-99m-methoxy isobutyl isonitrile redistribution
    • Maurea S, Cuocolo A, Soricelli A, et al. Myocardial viability index in chronic artery disease: technetium-99m-methoxy isobutyl isonitrile redistribution. J Nucl Med 1995; 36:1953-1960.
    • (1995) J Nucl Med , vol.36 , pp. 1953-1960
    • Maurea, S.1    Cuocolo, A.2    Soricelli, A.3
  • 46
    • 0029777397 scopus 로고    scopus 로고
    • Reverse redistribution of technetium-99m-sestamibi following direct PTCA in acute myocardial infarction
    • Takeishi Y, Sukekawa H, Fujiwara S, Ikeno E, Sasaki Y, Tomoike H. Reverse redistribution of technetium-99m-sestamibi following direct PTCA in acute myocardial infarction. J Nucl Med 1996; 37:1289-1294.
    • (1996) J Nucl Med , vol.37 , pp. 1289-1294
    • Takeishi, Y.1    Sukekawa, H.2    Fujiwara, S.3    Ikeno, E.4    Sasaki, Y.5    Tomoike, H.6
  • 47
    • 15644361830 scopus 로고    scopus 로고
    • Predictive value of rest-redistribution Tc-99m-tetrofosmin SPECT in the detection of residual viability in the territory of infarct related artery in the late phase of MI
    • Lipiecki J, Bourgeois V, Maublant J, et al. Predictive value of rest-redistribution Tc-99m-tetrofosmin SPECT in the detection of residual viability in the territory of infarct related artery in the late phase of MI [abstract]. J Am Coll Cardiol 1997; 29:1652.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 1652
    • Lipiecki, J.1    Bourgeois, V.2    Maublant, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.