Volumn 25, Issue 11, 1998, Pages 2170-2175

Optimum tube voltage for chest radiographs obtained by psychophysical analysis

Author keywords

Chest radiograph; Minimum perceptible contrast; Psychophysical analysis; X ray spectrum; X ray tube voltage

Indexed keywords

SPECTRUM ANALYSIS; TUBES (COMPONENTS); X RAY FILMS; X RAY TUBES; X RAYS;

EID: 0031740182     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598413     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0040812354 scopus 로고
    • The determination of the optimum density and the density-range of radiographs from visual effects
    • H. Kanamori, "The determination of the optimum density and the density-range of radiographs from visual effects," Jpn. J. Appl. Phys. 3, 286-294 (1964).
    • (1964) Jpn. J. Appl. Phys. , vol.3 , pp. 286-294
    • Kanamori, H.1
  • 2
    • 0013931049 scopus 로고
    • Determination of optimum film density range for roentgenograms from visual effects
    • H. Kanamori, "Determination of optimum film density range for roentgenograms from visual effects," Acta Radiol., Diagn. 4, 463-476 (1966).
    • (1966) Acta Radiol., Diagn. , vol.4 , pp. 463-476
    • Kanamori, H.1
  • 3
    • 0027328328 scopus 로고
    • Effects of x-ray tube ripple and current mode on patient dose
    • H. Kubota, Y. Ozaki, M. Matsumoto, and H. Kanamori, "Effects of x-ray tube ripple and current mode on patient dose," Med. Phys. 20, 1023-1028 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1023-1028
    • Kubota, H.1    Ozaki, Y.2    Matsumoto, M.3    Kanamori, H.4
  • 4
    • 0014747653 scopus 로고
    • X-ray sensitometer for screen-film combinations used in medical radiology
    • A. G Haus and K Rossmann, "X-ray sensitometer for screen-film combinations used in medical radiology," Radiology 94, 673-678 (1970).
    • (1970) Radiology , vol.94 , pp. 673-678
    • Haus, A.G.1    Rossmann, K.2
  • 5
    • 0012702902 scopus 로고
    • Frequency dependence of minimum perceptible contrasts and optimum film densities of radiographs
    • Y. Ozaki, H. Kubota, M. Matsumoto, and H. Kanamori, "Frequency dependence of minimum perceptible contrasts and optimum film densities of radiographs," J. Photogr. Sci. 41, 59-62 (1993).
    • (1993) J. Photogr. Sci. , vol.41 , pp. 59-62
    • Ozaki, Y.1    Kubota, H.2    Matsumoto, M.3    Kanamori, H.4
  • 6
    • 0012658530 scopus 로고
    • Frequency dependence of minimum perceptible contrasts of radiographs and MTF of the eye
    • Y. Ozaki, H. Kubota, M. Matsumoto, and H. Kanamori, "Frequency dependence of minimum perceptible contrasts of radiographs and MTF of the eye," J Photogr. Sci. 41, 96-97 (1993).
    • (1993) J Photogr. Sci. , vol.41 , pp. 96-97
    • Ozaki, Y.1    Kubota, H.2    Matsumoto, M.3    Kanamori, H.4
  • 7
    • 0010952038 scopus 로고
    • Equivalent spatial frequency and optimum film densities for the perceptibility of radiographic contrast of step-edge images
    • M. Matsumoto, Y. Ozaki, H. Kubota, Y. Asai, and H. Kanamori, "Equivalent spatial frequency and optimum film densities for the perceptibility of radiographic contrast of step-edge images," J. Photogr. Sci. 43, 99-102 (1995)
    • (1995) J. Photogr. Sci. , vol.43 , pp. 99-102
    • Matsumoto, M.1    Ozaki, Y.2    Kubota, H.3    Asai, Y.4    Kanamori, H.5
  • 8
    • 0018399326 scopus 로고
    • Computation of bremsstrahlung x-ray spectra and comparison with measured Ge(Li) detector
    • R. Birch and M. Marshall, "Computation of bremsstrahlung x-ray spectra and comparison with measured Ge(Li) detector," Phys. Med. Biol 24, 505-517 (1979).
    • (1979) Phys. Med. Biol , vol.24 , pp. 505-517
    • Birch, R.1    Marshall, M.2
  • 9
    • 0006360788 scopus 로고
    • Emission of characteristic L and K radiation from thick tungsten target
    • E. Storm, "Emission of characteristic L and K radiation from thick tungsten target," J. Appl. Phys. 43, 2790-2796 (1972).
    • (1972) J. Appl. Phys. , vol.43 , pp. 2790-2796
    • Storm, E.1
  • 10
    • 0017667206 scopus 로고
    • Screen-film system speed: Its dependence on x-ray energy
    • C. J. Vybomy, C. E. Metz, K. Doi, and K. Rossmann, "Screen-film system speed: Its dependence on x-ray energy," Radiology 125, 811-816 (1977).
    • (1977) Radiology , vol.125 , pp. 811-816
    • Vybomy, C.J.1    Metz, C.E.2    Doi, K.3    Rossmann, K.4
  • 12
    • 7844229384 scopus 로고
    • Effects of roentgen tube voltage and current waveforms in radiography
    • H. Kanamori, "Effects of roentgen tube voltage and current waveforms in radiography," Acta Radiol.: Ther , Phys., Biol. 4, 68-80 (1966).
    • (1966) Acta Radiol.: Ther , Phys., Biol. , vol.4 , pp. 68-80
    • Kanamori, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.