메뉴 건너뛰기




Volumn 37, Issue 12, 1998, Pages 213-218

The use of an on-line respirometer for the screening of toxicity in the Antwerp WWTP catchment area

Author keywords

Inhibition; Nutrient removal; On line monitoring; Respirometer; Sewer system; Toxicity; WWTP

Indexed keywords

ACTIVATED SLUDGE PROCESS; EFFLUENT TREATMENT; LAWS AND LEGISLATION; NITRIFICATION; NITROGEN; PHOSPHORUS; TOXICITY; WASTEWATER TREATMENT;

EID: 0031728065     PISSN: 02731223     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0273-1223(98)00360-6     Document Type: Conference Paper
Times cited : (11)

References (7)
  • 1
    • 0021283772 scopus 로고
    • The effects of organotin on the activated sludge process
    • Y. Argaman C.E. Hucks S.E. Shelby The effects of organotin on the activated sludge process Water Res. 18 5 1984 535 542
    • (1984) Water Res. , vol.18 , Issue.5 , pp. 535-542
    • Argaman, Y.1    Hucks, C.E.2    Shelby, S.E.3
  • 2
    • 85119798637 scopus 로고
    • J. Berlamont Rioleringen 4th ed. 1990 Acco Leuven
    • (1990)
    • Berlamont, J.1
  • 3
    • 0028088622 scopus 로고
    • Treatment and pretreatment requirements for industrial wastewaters in municipal activated sludge plants
    • W.W. Eckenfelder J.L. Musterman Treatment and pretreatment requirements for industrial wastewaters in municipal activated sludge plants Wat. Sci. Tech. 29 9 1994 79 88
    • (1994) Wat. Sci. Tech. , vol.29 , Issue.9 , pp. 79-88
    • Eckenfelder, W.W.1    Musterman, J.L.2
  • 4
    • 1542587284 scopus 로고    scopus 로고
    • Biological aerated filter: an alternative to reduce the Antwerp WWTP footprint
    • D. Geenens C. Thoeye G. Parmentier Biological aerated filter: an alternative to reduce the Antwerp WWTP footprint H. Verachten W. Verstraete Proceedings International Symposium Environmental Biotechnology. Oostende, Belgium, April 21–23 1997 3 1997 30 33
    • (1997) , pp. 30-33
    • Geenens, D.1    Thoeye, C.2    Parmentier, G.3
  • 5
    • 0027211965 scopus 로고
    • An activated sludge-based biosensor for rapid ICSO estimation and online toxicity monitoring
    • Z. Kong P.A. Vanrolleghem W. Verstraete An activated sludge-based biosensor for rapid ICSO estimation and online toxicity monitoring Biosens. Bioelectron. 8 1993 49 58
    • (1993) Biosens. Bioelectron. , vol.8 , pp. 49-58
    • Kong, Z.1    Vanrolleghem, P.A.2    Verstraete, W.3
  • 6
    • 0022978361 scopus 로고
    • Reasons for variable treatment performance and possible approaches to improving the process stability of sewage treatment installations
    • P. Kunz Reasons for variable treatment performance and possible approaches to improving the process stability of sewage treatment installations Abwassertechnik 37 6 1986 12 17
    • (1986) Abwassertechnik , vol.37 , Issue.6 , pp. 12-17
    • Kunz, P.1
  • 7
    • 0029898224 scopus 로고    scopus 로고
    • Full-scale on-line assessment of toxic wastewater causing change in biodegradation model structure and parameters
    • P.A. Vanrolleghem Z. Kong F. Coen Full-scale on-line assessment of toxic wastewater causing change in biodegradation model structure and parameters Wat. Sci. Tech. 33 2 1996 163 175
    • (1996) Wat. Sci. Tech. , vol.33 , Issue.2 , pp. 163-175
    • Vanrolleghem, P.A.1    Kong, Z.2    Coen, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.