-
1
-
-
0000069449
-
New method of surgical treatment of blood vessel lesions
-
Androsov PI: New method of surgical treatment of blood vessel lesions. Arch Surg 73:902, 1956
-
(1956)
Arch Surg
, vol.73
, pp. 902
-
-
Androsov, P.I.1
-
2
-
-
3042665021
-
Operations in cases of aneurysmas: Restoration of continuity of arteries by means of grafts without isolating aneurysmatic sac
-
Androsov PI: Operations in cases of aneurysmas: Restoration of continuity of arteries by means of grafts without isolating aneurysmatic sac. Arch Surg 73:911, 1956
-
(1956)
Arch Surg
, vol.73
, pp. 911
-
-
Androsov, P.I.1
-
3
-
-
0026666106
-
Sutureless vasovasostomie: New technique using experimental microclip in rat model
-
Gaskill DM, Stewart S, Kirsch WM, et al: Sutureless vasovasostomie: New technique using experimental microclip in rat model. Urology 40:191, 1992
-
(1992)
Urology
, vol.40
, pp. 191
-
-
Gaskill, D.M.1
Stewart, S.2
Kirsch, W.M.3
-
4
-
-
0012452765
-
A new type of vessel-suturing apparatus
-
Inokuchi K: A new type of vessel-suturing apparatus. Arch Surg 77:954, 1958
-
(1958)
Arch Surg
, vol.77
, pp. 954
-
-
Inokuchi, K.1
-
5
-
-
0027085680
-
A new method for microvascular anastomosis
-
Kirsch WM, Zhu YH, Hardesty RA, et al: A new method for microvascular anastomosis. Am Surg 58:722, 1992
-
(1992)
Am Surg
, vol.58
, pp. 722
-
-
Kirsch, W.M.1
Zhu, Y.H.2
Hardesty, R.A.3
-
7
-
-
0001544685
-
A concept of automation in vascular surgery: A preliminary report on a mechanical instrument for arterial anastomosis
-
Vogelfanger IJ, Beattie WG: A concept of automation in vascular surgery: A preliminary report on a mechanical instrument for arterial anastomosis. Can J Surg 1:262, 1958
-
(1958)
Can J Surg
, vol.1
, pp. 262
-
-
Vogelfanger, I.J.1
Beattie, W.G.2
-
8
-
-
0023640508
-
Mechanical anastomosis of small arteries and veins with the Unilink Apparatus: A histologic and scanning electron microscopic study
-
Berggren A, Östrup LT, Lidman D: Mechanical anastomosis of small arteries and veins with the Unilink Apparatus: A histologic and scanning electron microscopic study. Plast Reconstr Surg 80:274, 1987
-
(1987)
Plast Reconstr Surg
, vol.80
, pp. 274
-
-
Berggren, A.1
Östrup, L.T.2
Lidman, D.3
-
9
-
-
0000192720
-
A new technique for end-to-end anastomosis of small arteries
-
Holt GP, Lewis FJ: A new technique for end-to-end anastomosis of small arteries. Surg Forum 11:242, 1960
-
(1960)
Surg Forum
, vol.11
, pp. 242
-
-
Holt, G.P.1
Lewis, F.J.2
-
10
-
-
0000222491
-
Microsurgery in anastomosis of small vessels
-
Jacobson JH, Suarez EL: Microsurgery in anastomosis of small vessels. Surg Forum 11:243, 1960
-
(1960)
Surg Forum
, vol.11
, pp. 243
-
-
Jacobson, J.H.1
Suarez, E.L.2
-
11
-
-
0000170259
-
Experience with free autografts of the bowel with a new venous anastomosis apparatus
-
Nakayama K, Yamamoto K, Tamiya T, et al: Experience with free autografts of the bowel with a new venous anastomosis apparatus. Surgery 55:796, 1964
-
(1964)
Surgery
, vol.55
, pp. 796
-
-
Nakayama, K.1
Yamamoto, K.2
Tamiya, T.3
-
12
-
-
0021277497
-
An absorbable anastomotic device for microvascular surgery: Experimental studies
-
Daniel RK, Olding M: An absorbable anastomotic device for microvascular surgery: Experimental studies. Plast Reconstr Surg 74:329, 1984
-
(1984)
Plast Reconstr Surg
, vol.74
, pp. 329
-
-
Daniel, R.K.1
Olding, M.2
-
13
-
-
0024458068
-
Nonsuture microsurgical vessel anastomosis using an absorbable cuff
-
Euler E, Lechtleuthner A, Stephan F, et al: Nonsuture microsurgical vessel anastomosis using an absorbable cuff. J Reconstr Microsurg 5:323, 1989
-
(1989)
J Reconstr Microsurg
, vol.5
, pp. 323
-
-
Euler, E.1
Lechtleuthner, A.2
Stephan, F.3
-
14
-
-
0001098666
-
Internal mammary-coronary artery anastomosis: A nonsuture method employing tantalum rings
-
Goetz RH, Rohmann M, Haller JD, et al: Internal mammary-coronary artery anastomosis: A nonsuture method employing tantalum rings. J Thorac Cardiovasc Surg 41:378, 1961
-
(1961)
J Thorac Cardiovasc Surg
, vol.41
, pp. 378
-
-
Goetz, R.H.1
Rohmann, M.2
Haller, J.D.3
-
15
-
-
0343906589
-
Long term results of small vessel anastomoses with a ring technique
-
Haller JD, Kripke DC, Rosenak SS: Long term results of small vessel anastomoses with a ring technique. Ann Surg 161:67, 1965
-
(1965)
Ann Surg
, vol.161
, pp. 67
-
-
Haller, J.D.1
Kripke, D.C.2
Rosenak, S.S.3
-
16
-
-
0026079691
-
Sutureless vascular anastomosis with biocompatible heat-shrinking tubing
-
Mattox DE, Wozniak JJ: Sutureless vascular anastomosis with biocompatible heat-shrinking tubing. Arch Otolaryngol Head Neck Surg 117:1260, 1991
-
(1991)
Arch Otolaryngol Head Neck Surg
, vol.117
, pp. 1260
-
-
Mattox, D.E.1
Wozniak, J.J.2
-
17
-
-
0022412135
-
A new sutureless method for the anastomosis of blood vessels
-
Wozniak JJ: A new sutureless method for the anastomosis of blood vessels. Biomater Med Devices Artif Organs 13:51, 1985
-
(1985)
Biomater Med Devices Artif Organs
, vol.13
, pp. 51
-
-
Wozniak, J.J.1
-
18
-
-
0021845767
-
The diagnostic value of the new method for the study of undecalcified bones and teeth with attached soft tissue
-
Donath K: The diagnostic value of the new method for the study of undecalcified bones and teeth with attached soft tissue. Path Res Pract 179:631, 1985
-
(1985)
Path Res Pract
, vol.179
, pp. 631
-
-
Donath, K.1
-
19
-
-
0024358387
-
Microvenous end-to-side anastomosis: An experimental study comparing the unilink system and sutures
-
Ragnarsson R, Berggren A, Östrup LT: Microvenous end-to-side anastomosis: An experimental study comparing the unilink system and sutures. J Reconstr Microsurg 5:217, 1989
-
(1989)
J Reconstr Microsurg
, vol.5
, pp. 217
-
-
Ragnarsson, R.1
Berggren, A.2
Östrup, L.T.3
-
20
-
-
0024519668
-
Arterial end-to-side anastomosis with the "Unilink-System."
-
Ragnarsson R, Berggren A, Östrup LT, et al: Arterial end-to-side anastomosis with the "Unilink-System." Ann Plast Surg 22:405, 1989
-
(1989)
Ann Plast Surg
, vol.22
, pp. 405
-
-
Ragnarsson, R.1
Berggren, A.2
Östrup, L.T.3
-
21
-
-
0025751640
-
End-to-side-anastomosis in the dog using the 3M Precise microvascular anastomotic system: A comparative study
-
Yanni L, Wood MB: End-to-side-anastomosis in the dog using the 3M Precise microvascular anastomotic system: A comparative study. J Reconstr Microsurg 7:345, 1991
-
(1991)
J Reconstr Microsurg
, vol.7
, pp. 345
-
-
Yanni, L.1
Wood, M.B.2
-
22
-
-
13144254513
-
Experimentelle Untersuchungen zur mikrovaskulären Anastomose mit einem Ringstiftsystem beim Kaninchen. Technik und histologische Befunde
-
Reinert S, Horn H, Bürrig KF: Experimentelle Untersuchungen zur mikrovaskulären Anastomose mit einem Ringstiftsystem beim Kaninchen. Technik und histologische Befunde. Dtsch Z Mund Kiefer GesichtsChir 18:282, 1994
-
(1994)
Dtsch Z Mund Kiefer GesichtsChir
, vol.18
, pp. 282
-
-
Reinert, S.1
Horn, H.2
Bürrig, K.F.3
-
23
-
-
13144294338
-
Experimentelle Untersuchungen zur mikrovaskulären Anastomose mit einem Ringstiftsystem beim Kaninchen: Rasterelektronenmikroskopische Befunde
-
Reinert S, Bürrig KF: Experimentelle Untersuchungen zur mikrovaskulären Anastomose mit einem Ringstiftsystem beim Kaninchen: Rasterelektronenmikroskopische Befunde. Dsch Z Mund Kiefer Gesichts Chir 19:245, 1995
-
(1995)
Dsch Z Mund Kiefer Gesichts Chir
, vol.19
, pp. 245
-
-
Reinert, S.1
Bürrig, K.F.2
-
25
-
-
0017571395
-
The histopathology of small arteries following experimental microvascular anastomosis
-
Acland RD, Trachtenberg L: The histopathology of small arteries following experimental microvascular anastomosis. Plast Reconstr Surg 59:868, 1977
-
(1977)
Plast Reconstr Surg
, vol.59
, pp. 868
-
-
Acland, R.D.1
Trachtenberg, L.2
-
26
-
-
0024520579
-
A microvascular anastomotic device: Part II. Histologic study in arteries and veins
-
Blair WF, Morecraft RJ, Steyers CM, et al: A microvascular anastomotic device: Part II. Histologic study in arteries and veins. Microsurgery 10:29, 1989
-
(1989)
Microsurgery
, vol.10
, pp. 29
-
-
Blair, W.F.1
Morecraft, R.J.2
Steyers, C.M.3
-
27
-
-
0022830388
-
The Unilink Instrument System for fast and safe microvascular anastomosis
-
Östrup LT, Berggren A: The Unilink Instrument System for fast and safe microvascular anastomosis. Ann Plast Surg 17:521, 1986
-
(1986)
Ann Plast Surg
, vol.17
, pp. 521
-
-
Östrup, L.T.1
Berggren, A.2
-
28
-
-
0021723338
-
An anastomotic device for microvascular surgery: Evolution
-
Daniel RK, Lidman D, Olding M, et al: An anastomotic device for microvascular surgery: Evolution. Ann Plast Surg 13:402, 1983
-
(1983)
Ann Plast Surg
, vol.13
, pp. 402
-
-
Daniel, R.K.1
Lidman, D.2
Olding, M.3
-
29
-
-
0025063768
-
Evaluation of the Unilink microvascular anastomotic device in the dog
-
Falconer DP, Lewis TW, Lamprecht EG, et al: Evaluation of the Unilink microvascular anastomotic device in the dog. J Reconstr Microsurg 6:215, 1990
-
(1990)
J Reconstr Microsurg
, vol.6
, pp. 215
-
-
Falconer, D.P.1
Lewis, T.W.2
Lamprecht, E.G.3
-
30
-
-
0026465565
-
Long-term results of 1 millimeter arterial anastomosis using the 3M precise microvascular anastomotic system
-
Lanzetta M, Owen ER: Long-term results of 1 millimeter arterial anastomosis using the 3M precise microvascular anastomotic system. Microsurgery 13:313, 1992
-
(1992)
Microsurgery
, vol.13
, pp. 313
-
-
Lanzetta, M.1
Owen, E.R.2
-
31
-
-
0027209050
-
Use of the 3M Precise microvascular anastomotic system in grafting 1-mm diameter arteries with polytetrafluoroethylene prostheses: A long-term study
-
Lanzetta M, Owen ER: Use of the 3M Precise microvascular anastomotic system in grafting 1-mm diameter arteries with polytetrafluoroethylene prostheses: A long-term study. J Reconstr Microsurg 9:173, 1993
-
(1993)
J Reconstr Microsurg
, vol.9
, pp. 173
-
-
Lanzetta, M.1
Owen, E.R.2
-
32
-
-
0028859558
-
Experimental evaluation and clinical use in the head and neck of a 3M/Precise microvascular anastomotic device
-
Borja-Morant A, Navarro-Vila C, Cuesta-Gil M, et al: Experimental evaluation and clinical use in the head and neck of a 3M/Precise microvascular anastomotic device. J Craniomaxillofac Surg 23:305, 1995
-
(1995)
J Craniomaxillofac Surg
, vol.23
, pp. 305
-
-
Borja-Morant, A.1
Navarro-Vila, C.2
Cuesta-Gil, M.3
-
33
-
-
0025827592
-
End-to-side-anastomosis in the dog using the 3M Precise microvascular anastomotic system: A comparative study
-
Daniel R: End-to-side-anastomosis in the dog using the 3M Precise microvascular anastomotic system: A comparative study (invited discussion). J Reconstr Microsurg 7:351, 1991
-
(1991)
J Reconstr Microsurg
, vol.7
, pp. 351
-
-
Daniel, R.1
|