메뉴 건너뛰기




Volumn 33, Issue 3, 1998, Pages 199-206

Development of a fully integrated microdistillation flow injection system for the determination of trace level ammonia

Author keywords

Ammonia analysis; Ammonia ion selective electrode; Flow injection analysis; Microstill pre concentration; Simplex optimisation

Indexed keywords

AMMONIA;

EID: 0031727408     PISSN: 1381141X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1381-141X(98)80005-1     Document Type: Article
Times cited : (5)

References (23)
  • 1
    • 0039343543 scopus 로고
    • Applications of flow injection analysis in a power plant determination of pH, ammonia and hydrazine in an avt-conditioned water steam cycle
    • M.L. Balconi, F. Sigon, R. Ferraroli, F. Realini, Applications of flow injection analysis in a power plant determination of pH, ammonia and hydrazine in an avt-conditioned water steam cycle, Anal. Chim. Acta 214 (1988) 367-374.
    • (1988) Anal. Chim. Acta , vol.214 , pp. 367-374
    • Balconi, M.L.1    Sigon, F.2    Ferraroli, R.3    Realini, F.4
  • 2
    • 0000384988 scopus 로고
    • Alternate washing method for flow-through determination of ammonium ion using an ammonia gas electrode
    • H. Hara, A. Motoike, S. Okaxaki, Alternate washing method for flow-through determination of ammonium ion using an ammonia gas electrode, Anal. Chem. 59 (1987) 1995-1999.
    • (1987) Anal. Chem. , vol.59 , pp. 1995-1999
    • Hara, H.1    Motoike, A.2    Okaxaki, S.3
  • 3
    • 0344471218 scopus 로고
    • Continuous monitoring for ammonia and nitrate using ion-selective electrodes
    • M.D. Stewart, Continuous monitoring for ammonia and nitrate using ion-selective electrodes, Ultrapure Water 5 (10) (1988) 24-38.
    • (1988) Ultrapure Water , vol.5 , Issue.10 , pp. 24-38
    • Stewart, M.D.1
  • 4
    • 0004076897 scopus 로고
    • Continuous-flow system for the accurate determination of low concentrations of ammonium ions using a gas permeable Poly(tetrafluoroethylene) tube decontaminator and an ammonia gas-sensing membrane electrode
    • H. Hara, S. Matsumoto, Continuous-flow system for the accurate determination of low concentrations of ammonium ions using a gas permeable Poly(tetrafluoroethylene) tube decontaminator and an ammonia gas-sensing membrane electrode, Analyst 119 (1994) 1839-1842.
    • (1994) Analyst , vol.119 , pp. 1839-1842
    • Hara, H.1    Matsumoto, S.2
  • 5
    • 84972905371 scopus 로고
    • Flow injection determination of ammonia-N using a polymer membrane electrode-based gas sensing system
    • M.E. Meyerhoff, Y.M. Fraticelli, Flow injection determination of ammonia-N using a polymer membrane electrode-based gas sensing system, Anal. Lett. 14 (B6) (1981) 415-432.
    • (1981) Anal. Lett. , vol.14 , Issue.B6 , pp. 415-432
    • Meyerhoff, M.E.1    Fraticelli, Y.M.2
  • 6
    • 0021846854 scopus 로고
    • Comparison of tubular polymeric pH and ammonium ion electrodes as detectors in the automated determination of ammonia
    • H.L. Lee, M.E. Meyerhoff, Comparison of tubular polymeric pH and ammonium ion electrodes as detectors in the automated determination of ammonia, Analyst 110 (1985) 371-376.
    • (1985) Analyst , vol.110 , pp. 371-376
    • Lee, H.L.1    Meyerhoff, M.E.2
  • 7
    • 0002551135 scopus 로고
    • Different approaches to the determination of ammonium ions at low levels by flow injection analysis
    • G. Schulze, C.Y. Liu, M. Brodowski, O. Elsholz, Different approaches to the determination of ammonium ions at low levels by flow injection analysis, Anal. Chim. Acta 214 (1988) 121-136.
    • (1988) Anal. Chim. Acta , vol.214 , pp. 121-136
    • Schulze, G.1    Liu, C.Y.2    Brodowski, M.3    Elsholz, O.4
  • 8
    • 0024834285 scopus 로고
    • Flow injection system for on-line potentiometric monitoring of ammonia in freshwater streams
    • S. Alegret, J. Alonso, J. Bartroli, E. Martinez-Fabregas, Flow injection system for on-line potentiometric monitoring of ammonia in freshwater streams, Analyst 114 (1989) 1443-1447.
    • (1989) Analyst , vol.114 , pp. 1443-1447
    • Alegret, S.1    Alonso, J.2    Bartroli, J.3    Martinez-Fabregas, E.4
  • 9
    • 0344789104 scopus 로고
    • Potentiometric and conductimetric determination of ammonium by gas diffusion flow injection analysis
    • W. Frenzel, C.Y. Liu, Potentiometric and conductimetric determination of ammonium by gas diffusion flow injection analysis, Fresenius J. Anal. Chem. 342 (1992) 276-280.
    • (1992) Fresenius J. Anal. Chem. , vol.342 , pp. 276-280
    • Frenzel, W.1    Liu, C.Y.2
  • 10
    • 84972990089 scopus 로고
    • Gas diffusion/permeation flow injection analysis: Part 1. Principles and instrumentation
    • V. Kuban, Gas diffusion/permeation flow injection analysis: Part 1. Principles and instrumentation, Crit. Rev. Anal. Chem. 23 (5) (1992) 323-354.
    • (1992) Crit. Rev. Anal. Chem. , vol.23 , Issue.5 , pp. 323-354
    • Kuban, V.1
  • 11
    • 0011821178 scopus 로고
    • Improved dynamic response of potentiometric ammonia sensors using pure teflon membranes
    • M.A. Arnold, Improved dynamic response of potentiometric ammonia sensors using pure teflon membranes, Anal. Chim. Acta 154 (1983) 33-39.
    • (1983) Anal. Chim. Acta , vol.154 , pp. 33-39
    • Arnold, M.A.1
  • 12
    • 0022116824 scopus 로고
    • Performance improvements of gas-diffusion ion-selective and enzyme electrodes
    • G.G. Guilbault, J.P. Czarnecki, M.A. Nabi Rahni, Performance improvements of gas-diffusion ion-selective and enzyme electrodes, Anal. Chem. 57 (1985) 2110-2116.
    • (1985) Anal. Chem. , vol.57 , pp. 2110-2116
    • Guilbault, G.G.1    Czarnecki, J.P.2    Nabi Rahni, M.A.3
  • 13
    • 0031406405 scopus 로고    scopus 로고
    • Development of an automated flow-injection system for the determination of trace level ammonia
    • C.W.K. Chow, R. Lane, T.C.W. Yeow, D.E. Davey, D.E. Mulcahy, Development of an automated flow-injection system for the determination of trace level ammonia, Lab. Autom. Inf. Manage. 33 (1997) 129-136.
    • (1997) Lab. Autom. Inf. Manage. , vol.33 , pp. 129-136
    • Chow, C.W.K.1    Lane, R.2    Yeow, T.C.W.3    Davey, D.E.4    Mulcahy, D.E.5
  • 15
    • 33846844316 scopus 로고
    • On-line separation and preconcentration in flow injection analysis
    • Z. Fang, Z. Zhu, S. Zhang, S. Xu, L. Guo, L. Sun, On-line separation and preconcentration in flow injection analysis, Anal. Chim. Acta 214 (1988) 41-55.
    • (1988) Anal. Chim. Acta , vol.214 , pp. 41-55
    • Fang, Z.1    Zhu, Z.2    Zhang, S.3    Xu, S.4    Guo, L.5    Sun, L.6
  • 16
    • 0026576889 scopus 로고
    • Gas permeation and preconcentration in the flow-injection determination of acid available cyanide in waste water
    • V. Kuban, Gas permeation and preconcentration in the flow-injection determination of acid available cyanide in waste water. Anal. Chim. Acta 259 (1992) 45-52.
    • (1992) Anal. Chim. Acta , vol.259 , pp. 45-52
    • Kuban, V.1
  • 18
    • 0031434438 scopus 로고    scopus 로고
    • An on-line microdistillation-based preconcentration technique for ammonia measurement
    • R. Lane, C.W.K. Chow, D.E. Davey, D.E. Mulcahy, S. McLeod, An on-line microdistillation-based preconcentration technique for ammonia measurement, Analyst 122 (1997) 1549-1552.
    • (1997) Analyst , vol.122 , pp. 1549-1552
    • Lane, R.1    Chow, C.W.K.2    Davey, D.E.3    Mulcahy, D.E.4    McLeod, S.5
  • 20
    • 0002048176 scopus 로고
    • Experimental optimization procedures in the determination of phosphate by flow-injection analysis
    • T.A.H.M. Janse, P.F.A. Van Der Wiel, G. Kateman, Experimental optimization procedures in the determination of phosphate by flow-injection analysis, Anal. Chim. Acta 155 (1983) 89-102.
    • (1983) Anal. Chim. Acta , vol.155 , pp. 89-102
    • Janse, T.A.H.M.1    Van Der Wiel, P.F.A.2    Kateman, G.3
  • 21
    • 0038270007 scopus 로고
    • Simultaneous optimization of variables in FIA systems by means of the simplex method
    • J. Alonso, J. Bartroli, J. Coello, M. del Valle, Simultaneous optimization of variables in FIA systems by means of the simplex method, Anal. Lett. 20 (8) (1987) 1247-1263.
    • (1987) Anal. Lett. , vol.20 , Issue.8 , pp. 1247-1263
    • Alonso, J.1    Bartroli, J.2    Coello, J.3    Del Valle, M.4
  • 23
    • 0000978029 scopus 로고
    • Trace gold determination by on-line preconcentration with flow injection atomic absorption spectrophotometry
    • P. Di, D.E. Davey, Trace gold determination by on-line preconcentration with flow injection atomic absorption spectrophotometry, Talanta 41 (4) (1994) 565-571.
    • (1994) Talanta , vol.41 , Issue.4 , pp. 565-571
    • Di, P.1    Davey, D.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.