Volumn 37, Issue 5, 1998, Pages 396-400

The benefit of electrical stimulation to enhance perfusion in persons with diabetes mellitus

Author keywords

Diabetes; Electricity; Perfusion; Ulceration

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DIABETES MELLITUS; DIABETIC FOOT; DIABETIC NEUROPATHY; ELECTROSTIMULATION THERAPY; FOOT ULCER; HUMAN; LASER DOPPLER FLOWMETRY; LEG BLOOD FLOW; OXIMETRY; SKIN BLOOD FLOW; TREATMENT OUTCOME; ULCER HEALING; WOUND HEALING;

EID: 0031726736     PISSN: 10672516     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1067-2516(98)80048-3     Document Type: Article
Times cited : (44)

References (26)
  • 1
    • 0025233640 scopus 로고
    • Causal pathways to amputation: Basis for prevention
    • Pecoraro, R. E., Reiber, G E., Burgess, E. M. Causal pathways to amputation: Basis for prevention. Diabetes Care 13:513-521, 1990.
    • (1990) Diabetes Care , vol.13 , pp. 513-521
    • Pecoraro, R.E.1    Reiber, G.E.2    Burgess, E.M.3
  • 2
    • 0031818156 scopus 로고    scopus 로고
    • Risk factors for above-knee amputation in diabetes mellitus
    • In press
    • van Houtum, W. H . Lavery, L. A., Armstrong, D. G. Risk factors for above-knee amputation in diabetes mellitus. South Med. J. In press, 1998.
    • (1998) South Med. J.
    • Van Houtum, W.H..1    Lavery, L.A.2    Armstrong, D.G.3
  • 3
    • 0021251920 scopus 로고
    • Assessment of perfusion in the diabetic foot by regional transcutaneous oximetry
    • Hauser, C. J., Klein, S R., Mehringer, C. M., Appel P., Shoemaker. W. C. Assessment of perfusion in the diabetic foot by regional transcutaneous oximetry. Diabetes 33:527-531, 1984.
    • (1984) Diabetes , vol.33 , pp. 527-531
    • Hauser, C.J.1    Klein, S.R.2    Mehringer, C.M.3    Appel, P.4    Shoemaker, W.C.5
  • 5
    • 0021823711 scopus 로고
    • Electrotherapy for acceleration of wound healing: Low density direct current
    • Carley, P. J., Electrotherapy for acceleration of wound healing: Low density direct current. Arch. Phys. Med. Rehabil. 66:443-446, 1985.
    • (1985) Arch. Phys. Med. Rehabil. , vol.66 , pp. 443-446
    • Carley, P.J.1
  • 6
    • 0025883921 scopus 로고
    • Chronic dermal ulcer healing enhanced with monophasic pulsed electrical stimulation
    • Feedar, J. A., Kloth, C., Gentzkow, D. Chronic dermal ulcer healing enhanced with monophasic pulsed electrical stimulation. Phys. Ther. 71:639-649, 1991.
    • (1991) Phys. Ther. , vol.71 , pp. 639-649
    • Feedar, J.A.1    Kloth, C.2    Gentzkow, D.3
  • 8
    • 0023940399 scopus 로고
    • Acceleration of wound healing with high voltage, monophasic pulsed current
    • Kloth, L. C., Feedar, A. Acceleration of wound healing with high voltage, monophasic pulsed current. Phys. Ther. 68:503-508, 1988.
    • (1988) Phys. Ther. , vol.68 , pp. 503-508
    • Kloth, L.C.1    Feedar, A.2
  • 9
    • 0023819679 scopus 로고
    • Effect of electrical nerve stimulation on healing of ischaemic skin flaps
    • Sept. 24
    • Lundeberg, T., Kjartansson, J., Samuelsson, U. Effect of electrical nerve stimulation on healing of ischaemic skin flaps. Lancet, Sept. 24, 1988.
    • (1988) Lancet
    • Lundeberg, T.1    Kjartansson, J.2    Samuelsson, U.3
  • 11
    • 0031035069 scopus 로고    scopus 로고
    • Effects of electrical stimulation on wound healing in patients with diabetic ulcers
    • Baker, L. L., Chambers, R., DeMuth, S. K., Vilaar, F. Effects of electrical stimulation on wound healing in patients with diabetic ulcers Diabetes Care 20:405-412, 1997.
    • (1997) Diabetes Care , vol.20 , pp. 405-412
    • Baker, L.L.1    Chambers, R.2    DeMuth, S.K.3    Vilaar, F.4
  • 12
    • 0023720570 scopus 로고
    • Transcutaneous electrical stimulation (TENS) increases survival of ischaemic musculocutaneous flaps
    • Kjartansson, J. Transcutaneous electrical stimulation (TENS) increases survival of ischaemic musculocutaneous flaps. Acta Physiol. Scand. 134:95-99, 1988.
    • (1988) Acta Physiol. Scand. , vol.134 , pp. 95-99
    • Kjartansson, J.1
  • 13
    • 0026808953 scopus 로고
    • Electrical nerve stimulation improves healing of diabetic ulcers
    • Lundeberg, T. C. M., Eriksson, V., Malm, M. Electrical nerve stimulation improves healing of diabetic ulcers. Ann. Plast. Surg. 29:328-331, 1992.
    • (1992) Ann. Plast. Surg. , vol.29 , pp. 328-331
    • Lundeberg, T.C.M.1    Eriksson, V.2    Malm, M.3
  • 14
    • 0023193670 scopus 로고
    • Effect of high voltage stimulation on blood vlow in the rat hind limb
    • Mohr, T., Akers, T. K., Wessman, H. C. Effect of high voltage stimulation on blood vlow in the rat hind limb. Phys. Ther. 67:526-533, 1987.
    • (1987) Phys. Ther. , vol.67 , pp. 526-533
    • Mohr, T.1    Akers, T.K.2    Wessman, H.C.3
  • 15
    • 0018150296 scopus 로고
    • Capillary growth in chronically stimulated adult skeletal muscle as studied by interval microscopy and histological methods in rabbits and rats
    • Myrhage, R., Hudlicka O. Capillary growth in chronically stimulated adult skeletal muscle as studied by interval microscopy and histological methods in rabbits and rats. Microvasc Res. 16:73-79, 1978.
    • (1978) Microvasc Res. , vol.16 , pp. 73-79
    • Myrhage, R.1    Hudlicka, O.2
  • 16
    • 0038355557 scopus 로고
    • Influence of frequencey of muscle stimulation on circulation in the stimulated extremity
    • Wakin, K. G. Influence of frequencey of muscle stimulation on circulation in the stimulated extremity. Arch. Phys. Med. Rehabil. 34:291, 1953.
    • (1953) Arch. Phys. Med. Rehabil. , vol.34 , pp. 291
    • Wakin, K.G.1
  • 17
    • 7844220844 scopus 로고
    • Effect of low-frequency pulsing electromagnetic fields on skin ulcers of venous origin in humans: A double blind study
    • Ieran, M. Effect of low-frequency pulsing electromagnetic fields on skin ulcers of venous origin in humans: a double blind study. Phys. Ther. 70:199-204, 1990.
    • (1990) Phys. Ther. , vol.70 , pp. 199-204
    • Ieran, M.1
  • 18
    • 0003512791 scopus 로고
    • World Health Organization, Geneva
    • World Health Organization. Second Report on Diabetes Mellitus. World Health Organization, Geneva, 1980.
    • (1980) Second Report on Diabetes Mellitus
  • 20
    • 0023694663 scopus 로고
    • Calcitonin gene-related peptide (CGRP) and transcutaneous electrical nerve stimulation (TENS) musculocutaneous flap in the rat
    • Kjartansson, J., Lundenberg, T., Samuelson, U. E., Dalsgaard, D. J., Heden, P. Calcitonin gene-related peptide (CGRP) and transcutaneous electrical nerve stimulation (TENS) musculocutaneous flap in the rat. Acta Physiol. Scand. 134:89-94, 1988.
    • (1988) Acta Physiol. Scand. , vol.134 , pp. 89-94
    • Kjartansson, J.1    Lundenberg, T.2    Samuelson, U.E.3    Dalsgaard, D.J.4    Heden, P.5
  • 21
    • 7844219711 scopus 로고
    • Effect of medium frequency electrical stimulation on local blood circulation to healthy muscle
    • Currier, D. P., Petrilli, C. R., Threlkeld, A. J. Effect of medium frequency electrical stimulation on local blood circulation to healthy muscle. J. Appl. Physiol. 50:493, 1981.
    • (1981) J. Appl. Physiol. , vol.50 , pp. 493
    • Currier, D.P.1    Petrilli, C.R.2    Threlkeld, A.J.3
  • 22
    • 7844250004 scopus 로고
    • edited by N. A. Currier, Appleton & Lange. Norwalk, CT
    • Currier, D. P. Clinical Electrotherapy, edited by N. A. Currier, Appleton & Lange. Norwalk, CT, pp. 156-158, 1987.
    • (1987) Clinical Electrotherapy , pp. 156-158
    • Currier, D.P.1
  • 23
    • 0023133257 scopus 로고
    • Circulatory response of digital arteries associated with electrical stimulation of calf muscle in healthy subjects
    • Lui, H., Currier, D. P., Threlkeld, A. J. Circulatory response of digital arteries associated with electrical stimulation of calf muscle in healthy subjects. Phys Ther. 67:340-345, 1987.
    • (1987) Phys Ther. , vol.67 , pp. 340-345
    • Lui, H.1    Currier, D.P.2    Threlkeld, A.J.3
  • 24
    • 0031446805 scopus 로고    scopus 로고
    • Changes in the electrical properties of the skin outermost layer during pulse electrotreatment
    • Indenbom, A. V., Kuzmin, P. I., Chizmadzhev, N. V., Yu, A. Changes in the electrical properties of the skin outermost layer during pulse electrotreatment. Memb. Cell. Biol. 11:367-380, 1997.
    • (1997) Memb. Cell. Biol. , vol.11 , pp. 367-380
    • Indenbom, A.V.1    Kuzmin, P.I.2    Chizmadzhev, N.V.3    Yu, A.4
  • 25
    • 0032079991 scopus 로고    scopus 로고
    • Factors affecting the in vivo precision of bioelectrical impedance analysis
    • Evans, W. D., McClagish, H., Trudgett, C. Factors affecting the in vivo precision of bioelectrical impedance analysis. Appl. Radiat. Isot. 49:485-487, 1998.
    • (1998) Appl. Radiat. Isot. , vol.49 , pp. 485-487
    • Evans, W.D.1    McClagish, H.2    Trudgett, C.3
  • 26
    • 0024000480 scopus 로고
    • Effects of unilateral, low-frequency, neuromuscular stimulation on superficial circulation in lower extremities of patients with peripheral vascular disease
    • Loubser, P. G., Cardus, D., Pickard, L. R., McTaggart, W. G. Effects of unilateral, low-frequency, neuromuscular stimulation on superficial circulation in lower extremities of patients with peripheral vascular disease Med. Instrument. 22:82-87, 1988.
    • (1988) Med. Instrument. , vol.22 , pp. 82-87
    • Loubser, P.G.1    Cardus, D.2    Pickard, L.R.3    McTaggart, W.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.