Evaluation of a dual sensor rate responsive pacing system based on a new concept

Author keywords

Accelerometer; Dual sensor; Minute ventilation; Rate responsive pacing

Indexed keywords

ACCELEROMETER; ADULT; AGED; ARTIFICIAL HEART PACEMAKER; BIOSENSOR; CLINICAL ARTICLE; CONFERENCE PAPER; FEMALE; HUMAN; LUNG MINUTE VOLUME; MALE; POSTOPERATIVE COMPLICATION; SINUS RHYTHM; TREADMILL EXERCISE;

EID: 0031724816     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1998.tb01152.x     Document Type: Review
Times cited : (19)

References (35)
  • 1
    • 0023088434 scopus 로고
    • Single-chamber cardiac pacing with activity-initiated chronotropic response: Evaluation by cardiopulmonary exercise testing
    • Benditt DG, Mianulli M, Fetter J, et al. Single-chamber cardiac pacing with activity-initiated chronotropic response: Evaluation by cardiopulmonary exercise testing. Circulation 1987; 75:184-191.
    • (1987) Circulation , vol.75 , pp. 184-191
    • Benditt, D.G.1    Mianulli, M.2    Fetter, J.3
  • 2
    • 0024429318 scopus 로고
    • Symptomatology and quality of life in patients with rate-responsive pacemakers: A double-blind, randomized, crossover study
    • Lau CP, Rushby J, Leigh-Jones M, et al. Symptomatology and quality of life in patients with rate-responsive pacemakers: A double-blind, randomized, crossover study. Clin Cardiol 1989; 12:505-512.
    • (1989) Clin Cardiol , vol.12 , pp. 505-512
    • Lau, C.P.1    Rushby, J.2    Leigh-Jones, M.3
  • 3
    • 0025563382 scopus 로고
    • Rate-modulated pacing
    • Furman S. Rate-modulated pacing. Circulation 1990; 82:1081-1094.
    • (1990) Circulation , vol.82 , pp. 1081-1094
    • Furman, S.1
  • 4
    • 0023088434 scopus 로고
    • Single-chamber cardiac pacing with activity-initiated chronotropic response; evaluation by cardiopulmonary testing
    • Benditt DG, Mianulli M, Fetter J, et al. Single-chamber cardiac pacing with activity-initiated chronotropic response; evaluation by cardiopulmonary testing. Circulation 1987; 75:184-191.
    • (1987) Circulation , vol.75 , pp. 184-191
    • Benditt, D.G.1    Mianulli, M.2    Fetter, J.3
  • 5
    • 30944441826 scopus 로고    scopus 로고
    • Response of a new accelerometer VVIR pacemaker during daily life tests
    • A Oto (ed.): Bologna, Italy, Monduzi Editore
    • Bowes R, Bonnet JL, Dixon M, et al. Response of a new accelerometer VVIR pacemaker during daily life tests. In A Oto (ed.): Cardiac Pacing 1995. Bologna, Italy, Monduzi Editore, pp. 59-62.
    • Cardiac Pacing 1995 , pp. 59-62
    • Bowes, R.1    Bonnet, J.L.2    Dixon, M.3
  • 6
    • 0023035776 scopus 로고
    • Electrode configurations for respiratory impedance measurement suitable for rate responsive pacing
    • Nappholtz T, Valenta H, Maloney J, et al. Electrode configurations for respiratory impedance measurement suitable for rate responsive pacing. PACE 1986; 9:960-964.
    • (1986) PACE , vol.9 , pp. 960-964
    • Nappholtz, T.1    Valenta, H.2    Maloney, J.3
  • 7
    • 0031931813 scopus 로고    scopus 로고
    • Measurement of minute ventilation with different DDDR pacemaker electrode configurations
    • Investigators of a Multicenter Study Evaluating the Chorus RM and Opus RM Pacemakers
    • Bonnet JL, Ritter P, Pioger G. Measurement of minute ventilation with different DDDR pacemaker electrode configurations. Investigators of a Multicenter Study Evaluating the Chorus RM and Opus RM Pacemakers. PACE 1998; 21:4-10.
    • (1998) PACE , vol.21 , pp. 4-10
    • Bonnet, J.L.1    Ritter, P.2    Pioger, G.3
  • 8
    • 0019377087 scopus 로고
    • Relation between QT interval and heart rate. New design of physiologically adaptive cardiac pacemaker
    • Rickards AF, Norman J. Relation between QT interval and heart rate. New design of physiologically adaptive cardiac pacemaker. Br Heart J 1981; 45:56-61.
    • (1981) Br Heart J , vol.45 , pp. 56-61
    • Rickards, A.F.1    Norman, J.2
  • 9
    • 0021733822 scopus 로고
    • Critical analysis of sensors for physiological responsive pacing
    • Gillette P. Critical analysis of sensors for physiological responsive pacing. PACE 1984; 7:1263-1266.
    • (1984) PACE , vol.7 , pp. 1263-1266
    • Gillette, P.1
  • 10
    • 0024598481 scopus 로고
    • Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers
    • Lau CP, Butrous GS, Ward DE, et al. Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers. Am J Cardiol 1989; 63:833-838.
    • (1989) Am J Cardiol , vol.63 , pp. 833-838
    • Lau, C.P.1    Butrous, G.S.2    Ward, D.E.3
  • 11
    • 0025907294 scopus 로고
    • A randomized double-blind crossover comparison of four rate-responsive pacing modes
    • Sulke N, Chambers J, Dritsas A, et al. A randomized double-blind crossover comparison of four rate-responsive pacing modes. J Am Coll Cardiol 1991; 17:696-706.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 696-706
    • Sulke, N.1    Chambers, J.2    Dritsas, A.3
  • 12
    • 0027988559 scopus 로고
    • Behavior of different activity-based pacemakers during treadmill exercise testing with variable slopes: A comparison of three activity-based pacing systems
    • Alt E, Matula M, Holzer K. Behavior of different activity-based pacemakers during treadmill exercise testing with variable slopes: A comparison of three activity-based pacing systems. PACE 1994; 17:1761-1770.
    • (1994) PACE , vol.17 , pp. 1761-1770
    • Alt, E.1    Matula, M.2    Holzer, K.3
  • 13
    • 0029858957 scopus 로고    scopus 로고
    • New integrated sensor pacemaker: Comparison of rate responses between an integrated minute ventilation and activity sensor and single sensor modes during exercise and daily activities and nonphysiological interference
    • Leung SK, Lau CP, Tang MO, et al. New integrated sensor pacemaker: Comparison of rate responses between an integrated minute ventilation and activity sensor and single sensor modes during exercise and daily activities and nonphysiological interference. PACE 1996; 19:1664-1671.
    • (1996) PACE , vol.19 , pp. 1664-1671
    • Leung, S.K.1    Lau, C.P.2    Tang, M.O.3
  • 14
    • 0030789675 scopus 로고    scopus 로고
    • Vibration, acceleration, gravitation, and movement: Activity controlled rate adaptive pacing during treadmill exercise testing and daily life activities
    • Candinas R, Jakob M, Buckingham TA, et al. Vibration, acceleration, gravitation, and movement: Activity controlled rate adaptive pacing during treadmill exercise testing and daily life activities. PACE 1997; 20:1777-1786.
    • (1997) PACE , vol.20 , pp. 1777-1786
    • Candinas, R.1    Jakob, M.2    Buckingham, T.A.3
  • 15
    • 0026801443 scopus 로고
    • Adaptive-rate pacemakers. Comparison of sensors and clinical experience
    • Katritsis D, Camm AJ. Adaptive-rate pacemakers. Comparison of sensors and clinical experience. Cardiol Clin 1992; 10:671-690.
    • (1992) Cardiol Clin , vol.10 , pp. 671-690
    • Katritsis, D.1    Camm, A.J.2
  • 16
    • 0027411574 scopus 로고
    • New and combined sensors for adaptive-rate pacing
    • Katritsis D, Shakespeare CF, Camm AJ. New and combined sensors for adaptive-rate pacing. Clin Cardiol 1993; 16:240-248.
    • (1993) Clin Cardiol , vol.16 , pp. 240-248
    • Katritsis, D.1    Shakespeare, C.F.2    Camm, A.J.3
  • 17
    • 0024240821 scopus 로고
    • A new rate-modulated pacemaker system optimized by combination of two sensors
    • Alt E, Theres H, Heinz M, et al. A new rate-modulated pacemaker system optimized by combination of two sensors. PACE 1988; 11:1119-1129.
    • (1988) PACE , vol.11 , pp. 1119-1129
    • Alt, E.1    Theres, H.2    Heinz, M.3
  • 18
    • 0024253713 scopus 로고
    • A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, and temperature, right atrial pressure, right ventricular pressure, and dP/dt
    • Stangl K, Wirtzfeld A, Heinze ML, et al. A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, and temperature, right atrial pressure, right ventricular pressure, and dP/dt. PACE 1988; 11:712-724.
    • (1988) PACE , vol.11 , pp. 712-724
    • Stangl, K.1    Wirtzfeld, A.2    Heinze, M.L.3
  • 19
    • 0026540156 scopus 로고
    • Clinical observations with a dual sensor rate adaptive single chamber pacemaker
    • Provenier F, van Acker R, Backers J, et al. Clinical observations with a dual sensor rate adaptive single chamber pacemaker. PACE 1992; 15:1821-1825.
    • (1992) PACE , vol.15 , pp. 1821-1825
    • Provenier, F.1    Van Acker, R.2    Backers, J.3
  • 20
    • 0027294026 scopus 로고
    • Initial experience with a new single chamber, dual sensor rate responsive pacemaker
    • The Topaz Study Group
    • Connelly DT. Initial experience with a new single chamber, dual sensor rate responsive pacemaker. The Topaz Study Group. PACE 1993; 16:1833-1841.
    • (1993) PACE , vol.16 , pp. 1833-1841
    • Connelly, D.T.1
  • 21
    • 0028913001 scopus 로고
    • Evaluation of a new rate adaptive ventricular pacemaker controlled by double sensors
    • Ovsyshcher I, Guldal M, Karaoguz R, et al. Evaluation of a new rate adaptive ventricular pacemaker controlled by double sensors. PACE 1995; 18:386-390.
    • (1995) PACE , vol.18 , pp. 386-390
    • Ovsyshcher, I.1    Guldal, M.2    Karaoguz, R.3
  • 22
    • 0031951261 scopus 로고    scopus 로고
    • Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers
    • Leung SK, Lau CP, Tang MO. Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers. PACE 1998; 21:35-41.
    • (1998) PACE , vol.21 , pp. 35-41
    • Leung, S.K.1    Lau, C.P.2    Tang, M.O.3
  • 23
    • 0028148531 scopus 로고
    • Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing
    • Leung SK, Lau CP, Wu CW, et al. Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing. PACE 1994; 17:1920-1927.
    • (1994) PACE , vol.17 , pp. 1920-1927
    • Leung, S.K.1    Lau, C.P.2    Wu, C.W.3
  • 24
    • 0027213798 scopus 로고
    • Are we being driven to two sensors?: Clinical benefits of sensor cross-checking
    • Cowell R, Morris-Thurgood J, Paul V, et al. Are we being driven to two sensors?: Clinical benefits of sensor cross-checking. PACE 1993; 16:1441-1444.
    • (1993) PACE , vol.16 , pp. 1441-1444
    • Cowell, R.1    Morris-Thurgood, J.2    Paul, V.3
  • 25
    • 0024322221 scopus 로고
    • A mathematical model of the cardiac chronotropic response to exercise
    • Wilkoff BL, Corey J, Blackburn G. A mathematical model of the cardiac chronotropic response to exercise. J Electrophysiol 1989; 3:176-180.
    • (1989) J Electrophysiol , vol.3 , pp. 176-180
    • Wilkoff, B.L.1    Corey, J.2    Blackburn, G.3
  • 26
    • 7344256482 scopus 로고
    • Evaluation of a minute ventilation rate adaptive pacemaker by cardio-pulmonary tests
    • Santini (ed.): Armonk, NY, Futura Publishing
    • Pioger G, Bonnet JL, Vai F, et al. Evaluation of a minute ventilation rate adaptive pacemaker by cardio-pulmonary tests. In Santini (ed.): Progress in Clinical Pacing. Armonk, NY, Futura Publishing, 1994, pp. 343-358.
    • (1994) Progress in Clinical Pacing , pp. 343-358
    • Pioger, G.1    Bonnet, J.L.2    Vai, F.3
  • 27
    • 0001905029 scopus 로고
    • Rate adaptive atrio-ventricular delay improves cardio-pulmonary performance in patients implanted with a dual chamber pacemaker for complete heart block
    • Ritter P, Vai F, Bonnet JL, et al. Rate adaptive atrio-ventricular delay improves cardio-pulmonary performance in patients implanted with a dual chamber pacemaker for complete heart block. Eur JCPE 1991; 1:31-38.
    • (1991) Eur JCPE , vol.1 , pp. 31-38
    • Ritter, P.1    Vai, F.2    Bonnet, J.L.3
  • 28
    • 7344222310 scopus 로고
    • A minute-ventilation sensor can provide a fast response at the beginning of short calibrated tests
    • Malinowski K, Morschhïuser D, Bonnet JL. A minute-ventilation sensor can provide a fast response at the beginning of short calibrated tests. Cardiostimolazione 1994; 12:229.
    • (1994) Cardiostimolazione , vol.12 , pp. 229
    • Malinowski, K.1    Morschhïuser, D.2    Bonnet, J.L.3
  • 29
    • 30944460464 scopus 로고
    • Rate response simulation software using the pacemaker Holter function
    • Bonnet JL, Baudoin C. Rate response simulation software using the pacemaker Holter function. (abstract) Cardiostimulazione 1992; 10:306.
    • (1992) Cardiostimulazione , vol.10 , pp. 306
    • Bonnet, J.L.1    Baudoin, C.2
  • 30
    • 30944457764 scopus 로고    scopus 로고
    • Evaluation clinique de la fonction de stimulation d'un stimulateur a frequence asservie
    • Bonnet JL. Evaluation clinique de la fonction de stimulation d'un stimulateur a frequence asservie. Stimucoeur 1996; 24:193-198.
    • (1996) Stimucoeur , vol.24 , pp. 193-198
    • Bonnet, J.L.1
  • 31
    • 0029993815 scopus 로고    scopus 로고
    • Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: Efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm
    • Lau CP, Leung SK, Guerola M, et al. Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: Efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm. PACE 1996; 19:1672-1677.
    • (1996) PACE , vol.19 , pp. 1672-1677
    • Lau, C.P.1    Leung, S.K.2    Guerola, M.3
  • 32
    • 30944441607 scopus 로고
    • Quantitative comparison of different sensor modes in multi sensor rate-adaptive pacing
    • Leung SK, Lau CP, Wu CW, et al.Quantitative comparison of different sensor modes in multi sensor rate-adaptive pacing. (abstract) Eur JCPE 1994; 4:37.
    • (1994) Eur JCPE , vol.4 , pp. 37
    • Leung, S.K.1    Lau, C.P.2    Wu, C.W.3
  • 33
    • 0029909075 scopus 로고    scopus 로고
    • Dual sensor VVIR mode pacing: Is it worth it?
    • Sulke N, Kamalvand K, Bostock J, et al. Dual sensor VVIR mode pacing: Is it worth it? PACE 1996; 19:1560-1567.
    • (1996) PACE , vol.19 , pp. 1560-1567
    • Sulke, N.1    Kamalvand, K.2    Bostock, J.3
  • 34
    • 0031010186 scopus 로고    scopus 로고
    • Dual sensor pacemakers in children: What is the choice of sensor blending?
    • Celiker A, Tokel K, Lenk MK, et al. Dual sensor pacemakers in children: What is the choice of sensor blending? PACE 1997; 20:1301-1304.
    • (1997) PACE , vol.20 , pp. 1301-1304
    • Celiker, A.1    Tokel, K.2    Lenk, M.K.3
  • 35
    • 0029790920 scopus 로고    scopus 로고
    • Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system: The importance of individual sensor programming
    • Lau CP, Leung SK, Lee IS. Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system: The importance of individual sensor programming. PACE 1996; 19:1021-1025.
    • (1996) PACE , vol.19 , pp. 1021-1025
    • Lau, C.P.1    Leung, S.K.2    Lee, I.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.