메뉴 건너뛰기




Volumn 44, Issue 10, 1998, Pages 2183-2190

CO-oximetry interference by perflubron emulsion: Comparison of hemolyzing and nonhemolyzing instruments

Author keywords

[No Author keywords available]

Indexed keywords

CARBON MONOXIDE; PERFLUOROOCTYL BROMIDE;

EID: 0031719993     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/44.10.2183     Document Type: Article
Times cited : (9)

References (17)
  • 4
    • 0020654224 scopus 로고
    • More on the performance of the IL282 CO-oximeter in the presence of perfluorochemical emulsion, Fluosol-DA
    • Tremper KK, Perloff W, Levine EM, Shippy C. More on the performance of the IL282 CO-oximeter in the presence of perfluorochemical emulsion, Fluosol-DA [Letter]. Clin Chem 1983;29: 209-10.
    • (1983) Clin Chem , vol.29 , pp. 209-210
    • Tremper, K.K.1    Perloff, W.2    Levine, E.M.3    Shippy, C.4
  • 6
    • 0030773472 scopus 로고    scopus 로고
    • Effect of hemoglobin- and perflubron-based oxygen carriers on common clinical laboratory tests
    • Ma Z, Monk TG, Goodnough LT, McClellan A, Gawryl M, Clark T, et al. Effect of hemoglobin- and perflubron-based oxygen carriers on common clinical laboratory tests. Clin Chem 1997;43:1732-7.
    • (1997) Clin Chem , vol.43 , pp. 1732-1737
    • Ma, Z.1    Monk, T.G.2    Goodnough, L.T.3    McClellan, A.4    Gawryl, M.5    Clark, T.6
  • 7
    • 7344245653 scopus 로고    scopus 로고
    • Plymouth Meeting, PA: ECRI Healthcare Product Comparison System
    • ECRI, Oximeters, in vitro, multiwavelength. Plymouth Meeting, PA: ECRI Healthcare Product Comparison System, 1998.
    • (1998) ECRI, Oximeters, in Vitro, Multiwavelength
  • 8
    • 0022885477 scopus 로고
    • Graphical comparisons of interferences in clinical chemistry instrumentation
    • Glick MR, Ryder KW, Jackson SA. Graphical comparisons of interferences in clinical chemistry instrumentation. Clin Chem 1986;32:470-5.
    • (1986) Clin Chem , vol.32 , pp. 470-475
    • Glick, M.R.1    Ryder, K.W.2    Jackson, S.A.3
  • 9
    • 0021154009 scopus 로고
    • Factitious methemoglobinemia caused by hyperlipemia
    • Spurzem JR, Bonekat HW, Shigeoka JW. Factitious methemoglobinemia caused by hyperlipemia. Chest 1984;86:84-6.
    • (1984) Chest , vol.86 , pp. 84-86
    • Spurzem, J.R.1    Bonekat, H.W.2    Shigeoka, J.W.3
  • 10
    • 0021984533 scopus 로고
    • Analytical interfer ence of lipid parenteral feeding with the determination of methemoglobin levels by an autoanalyzer
    • Rouillon JD, Toubin G, Moussard C, Magnin P. Analytical interfer ence of lipid parenteral feeding with the determination of methemoglobin levels by an autoanalyzer. Pathol Biol 1985;33:57-60.
    • (1985) Pathol Biol , vol.33 , pp. 57-60
    • Rouillon, J.D.1    Toubin, G.2    Moussard, C.3    Magnin, P.4
  • 11
    • 0021713071 scopus 로고
    • Effect of Intralipid on measurements of total hemoglobin and oxyhemoglobin in whole blood
    • Sehgal LR, Sehgal HL, Rosen AL, Gould SA, Moss GS. Effect of Intralipid on measurements of total hemoglobin and oxyhemoglobin in whole blood. Crit Care Med 1984;12:907-9.
    • (1984) Crit Care Med , vol.12 , pp. 907-909
    • Sehgal, L.R.1    Sehgal, H.L.2    Rosen, A.L.3    Gould, S.A.4    Moss, G.S.5
  • 12
    • 0024022346 scopus 로고
    • Diffusion model of the optical absorbance of whole blood
    • Steinke JM, Shepherd AP. Diffusion model of the optical absorbance of whole blood. J Opt Soc Am A 1988;5:813-22.
    • (1988) J Opt Soc Am A , vol.5 , pp. 813-822
    • Steinke, J.M.1    Shepherd, A.P.2
  • 13
    • 0022559446 scopus 로고
    • Role of light-scattering in whole blood oximetry
    • Steinke JM, Shepherd AP. Role of light-scattering in whole blood oximetry. IEEE Trans Biomed Eng 1986;BME-33:294-301.
    • (1986) IEEE Trans Biomed Eng , vol.BME-33 , pp. 294-301
    • Steinke, J.M.1    Shepherd, A.P.2
  • 14
    • 0027203757 scopus 로고
    • Evaluation of two oximeters for use in cardiac catheterization laboratories
    • Freeman GL, Steinke JM. Evaluation of two oximeters for use in cardiac catheterization laboratories. Cath Cardiovasc Diagn 1993; 30:51-7.
    • (1993) Cath Cardiovasc Diagn , vol.30 , pp. 51-57
    • Freeman, G.L.1    Steinke, J.M.2
  • 15
    • 0028815870 scopus 로고
    • Near-patient measurements of methemoglobin, oxygen saturation, and total hemoglobin: Evaluation of a new instrument for adult and neonatal intensive care
    • Gong AK. Near-patient measurements of methemoglobin, oxygen saturation, and total hemoglobin: evaluation of a new instrument for adult and neonatal intensive care. Crit Care Med 1995;23: 193-201.
    • (1995) Crit Care Med , vol.23 , pp. 193-201
    • Gong, A.K.1
  • 16
    • 0031147712 scopus 로고    scopus 로고
    • Evaluation of the AVOXimeter: Precision, long-term stability, linearity, and use without heparin
    • Bailey SR, Russell EL, Martinez A. Evaluation of the AVOXimeter: precision, long-term stability, linearity, and use without heparin. J Clin Monit 1997;13:191-8.
    • (1997) J Clin Monit , vol.13 , pp. 191-198
    • Bailey, S.R.1    Russell, E.L.2    Martinez, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.