메뉴 건너뛰기




Volumn 80, Issue 5, 1998, Pages 754-756

Femoral stem fixation

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT;

EID: 0031719146     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.80B5.8621     Document Type: Article
Times cited : (114)

References (14)
  • 1
    • 0027301351 scopus 로고
    • The outcome of Charnley total hip arthroplasty with cement after a minimum twenty year follow-up: The results of one surgeon
    • Schulte KR, Callaghan JJ, Kelley SS, Johnston RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty year follow-up: the results of one surgeon. J Bone Joint Surg [Am] 1993;75-A:961-75.
    • (1993) J Bone Joint Surg [Am] , vol.75 A , pp. 961-975
    • Schulte, K.R.1    Callaghan, J.J.2    Kelley, S.S.3    Johnston, R.C.4
  • 2
    • 0028267987 scopus 로고
    • Long-term results of Charnley total hip replacement: Review of 92 patients at 15 to 20 years
    • Neumann L, Freund KG, Sørenson KH. Long-term results of Charnley total hip replacement: review of 92 patients at 15 to 20 years. J Bone Joint Surg [Br] 1994;76-B:245-51.
    • (1994) J Bone Joint Surg [Br] , vol.76 B , pp. 245-251
    • Neumann, L.1    Freund, K.G.2    Sørenson, K.H.3
  • 3
    • 0019201514 scopus 로고
    • Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem
    • Loudon JR, Charnley J. Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem. J Bone Joint Surg [Br] 1980;62-B:450-3.
    • (1980) J Bone Joint Surg [Br] , vol.62 B , pp. 450-453
    • Loudon, J.R.1    Charnley, J.2
  • 4
    • 0016773856 scopus 로고
    • A radiological study of fractures of acrylic cement in relation to the stem of a femoral head prosthesis
    • Weber FA, Charnley J. A radiological study of fractures of acrylic cement in relation to the stem of a femoral head prosthesis. J Bone Joint Surg [Br] 1975;57-B:297-301.
    • (1975) J Bone Joint Surg [Br] , vol.57 B , pp. 297-301
    • Weber, F.A.1    Charnley, J.2
  • 5
    • 0027461703 scopus 로고
    • Fracture and loosening of Charnley femoral stems: Comparison between first-generation and subsequent designs
    • Dall DM, Learmonth ID, Solomon MI, Miles AW, Davenport JM. Fracture and loosening of Charnley femoral stems: comparison between first-generation and subsequent designs. J Bone Joint Surg [Br] 1993;75-B:259-65.
    • (1993) J Bone Joint Surg [Br] , vol.75 B , pp. 259-265
    • Dall, D.M.1    Learmonth, I.D.2    Solomon, M.I.3    Miles, A.W.4    Davenport, J.M.5
  • 7
    • 0003817626 scopus 로고    scopus 로고
    • Prognosis of total hip replacement, surgical and cementing technique in THR: A revision-risk study of 134 056 primary operations
    • Malchau H, Herberts P. Prognosis of total hip replacement, surgical and cementing technique in THR: a revision-risk study of 134 056 primary operations (in Sweden), 63rd Annual Meeting AAOS 1996.
    • (1996) 63rd Annual Meeting AAOS
    • Malchau, H.1    Herberts, P.2
  • 8
    • 0031465334 scopus 로고    scopus 로고
    • Exeter and Charnley arthroplasties with boneloc or high viscosity cement: Comparison of 1127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register
    • Furnes O, Lie SA, Havelin LI, Vollset SE, Engesaeter LB. Exeter and Charnley arthroplasties with boneloc or high viscosity cement: comparison of 1127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register. Acta Orthop Scand 1997;68:515-20.
    • (1997) Acta Orthop Scand , vol.68 , pp. 515-520
    • Furnes, O.1    Lie, S.A.2    Havelin, L.I.3    Vollset, S.E.4    Engesaeter, L.B.5
  • 9
    • 0007233061 scopus 로고
    • The long-term behaviour of a totally collarless, polished femoral component in cemented total hip arthroplasty
    • Gie GA, Fowler JL, Lee AJC, Ling RSM. The long-term behaviour of a totally collarless, polished femoral component in cemented total hip arthroplasty. J Bone Joint Surg [Br] 1990;72-B:935.
    • (1990) J Bone Joint Surg [Br] , vol.72 B , pp. 935
    • Gie, G.A.1    Fowler, J.L.2    Lee, A.J.C.3    Ling, R.S.M.4
  • 10
    • 0025047558 scopus 로고
    • Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties
    • Anthony PP, Gie GA, Howie CR, Ling RSM. Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg [Br] 1990;72-B:971-9.
    • (1990) J Bone Joint Surg [Br] , vol.72 B , pp. 971-979
    • Anthony, P.P.1    Gie, G.A.2    Howie, C.R.3    Ling, R.S.M.4
  • 11
    • 0002329666 scopus 로고
    • Charnley low friction arthroplasty (LFA): A 17-21-year follow-up study
    • Older J, Butorac R. Charnley low friction arthroplasty (LFA): a 17-21-year follow-up study. J Bone Joint Surg [Br] 1992;74-B:Supp III:251.
    • (1992) J Bone Joint Surg [Br] , vol.74 B , Issue.3 SUPPL. , pp. 251
    • Older, J.1    Butorac, R.2
  • 12
    • 0141858227 scopus 로고
    • The Charnley hip replacement: A longish-term review
    • Nicholson OR. The Charnley hip replacement: a longish-term review. J Bone Joint Surg [Br] 1992;74-B:Suppl I:37.
    • (1992) J Bone Joint Surg [Br] , vol.74 B , Issue.1 SUPPL. , pp. 37
    • Nicholson, O.R.1
  • 13
    • 0026443614 scopus 로고
    • Early and late loosening of the acetabular cup after low-friction arthroplasty
    • Garcia-Cimbrelo E, Munuera L. Early and late loosening of the acetabular cup after low-friction arthroplasty. J Bone Joint Surg [Am] 1992;74-A:1119-29.
    • (1992) J Bone Joint Surg [Am] , vol.74 A , pp. 1119-1129
    • Garcia-Cimbrelo, E.1    Munuera, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.