메뉴 건너뛰기




Volumn 8, Issue 3-4, 1998, Pages 233-240

Latex glove penetration by pathogens: A review of the literature

Author keywords

Bacteriophage; Examination gloves; Latex gloves; Surgical gloves; Vinyl gloves; Viral penetration

Indexed keywords

BACTERIOPHAGES; DESIGN; HEALTH CARE; HEALTH RISKS; LEAKAGE (FLUID); PERSONNEL; SURGERY;

EID: 0031694309     PISSN: 10506934     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (14)

References (11)
  • 1
    • 0042796183 scopus 로고
    • ASTM D 5151-92, November
    • American Society For Testing Materials, Annual Book of ASTM Standards, ASTM D 5151-92, November, 1992.
    • (1992) Annual Book of ASTM Standards
  • 2
    • 0025706275 scopus 로고
    • Adulteration
    • Medical Devices, Patient Examination and Surgeon's Gloves, Final Rule, 21 CFR Part 800, December 12
    • Food and Drug Administration, Medical Devices, Patient Examination and Surgeon's Gloves, Adulteration, Final Rule, 21 CFR Part 800, Federal Register, December 12, 1990, 55:51254-51258.
    • (1990) Federal Register , vol.55 , pp. 51254-51258
  • 3
    • 0024788259 scopus 로고
    • Latex and vinyl examination gloves: Quality control procedures and implications for health care workers
    • Kotilainen, R. H., Brinker, J., Avato, J., and Cantz, N. M., Latex and vinyl examination gloves: Quality control procedures and implications for health care workers, Arch. Intern. Med., 1989, 149:2749-2753.
    • (1989) Arch. Intern. Med. , vol.149 , pp. 2749-2753
    • Kotilainen, R.H.1    Brinker, J.2    Avato, J.3    Cantz, N.M.4
  • 5
    • 0023858924 scopus 로고
    • Surgical gloves as a mechanical barrier against human immunodeficiency virus
    • Dalgleish, A. G. and Malkovsky, M., Surgical gloves as a mechanical barrier against human immunodeficiency virus, Br. J. Surg., 1988, 75(2):171-172.
    • (1988) Br. J. Surg. , vol.75 , Issue.2 , pp. 171-172
    • Dalgleish, A.G.1    Malkovsky, M.2
  • 6
    • 0024559432 scopus 로고
    • Integrity of vinyl and latex procedure gloves
    • Korniewicz, D. M. and Laughon, B. E., Integrity of vinyl and latex procedure gloves, Nurs. Res., 1989, 38(3):144-146.
    • (1989) Nurs. Res. , vol.38 , Issue.3 , pp. 144-146
    • Korniewicz, D.M.1    Laughon, B.E.2
  • 7
    • 0025356271 scopus 로고
    • Leakage of virus through used vinyl and latex examination gloves
    • Korniewicz, D. M., Laughon, B. E., Cyr, H., Lytle, D., and Larson E., Leakage of virus through used vinyl and latex examination gloves, J. Clin. Microbiol., 1990, 28(4):787-788.
    • (1990) J. Clin. Microbiol. , vol.28 , Issue.4 , pp. 787-788
    • Korniewicz, D.M.1    Laughon, B.E.2    Cyr, H.3    Lytle, D.4    Larson, E.5
  • 8
    • 0025316906 scopus 로고
    • Latex and vinyl nonsterile examination gloves: Status report on laboratory evaluation of defects by physical and biological methods
    • Kotilainen, H. R., Avato J. L., and Gantz, N. M., Latex and vinyl nonsterile examination gloves: Status report on laboratory evaluation of defects by physical and biological methods, Appl. Environ. Microbiol., 1990, 56(6):1627-1630.
    • (1990) Appl. Environ. Microbiol. , vol.56 , Issue.6 , pp. 1627-1630
    • Kotilainen, H.R.1    Avato, J.L.2    Gantz, N.M.3
  • 9
    • 0026845239 scopus 로고
    • Microbial penetration of gloves after clinical usage
    • Pickett, T. E., Merchant, V. A., and Molinari, J. A., Microbial penetration of gloves after clinical usage, Am. J. Dent., 1992, 5(2):95-96.
    • (1992) Am. J. Dent. , vol.5 , Issue.2 , pp. 95-96
    • Pickett, T.E.1    Merchant, V.A.2    Molinari, J.A.3
  • 10
    • 0027772226 scopus 로고
    • Permeability of latex and thermoplastic elastomer gloves to the bacteriophage ØX174
    • Hamann, C. P. and Nelson, J. R., Permeability of latex and thermoplastic elastomer gloves to the bacteriophage ØX174, Am. J. Infect. Control., 1993, 21(6):289-296.
    • (1993) Am. J. Infect. Control. , vol.21 , Issue.6 , pp. 289-296
    • Hamann, C.P.1    Nelson, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.