메뉴 건너뛰기




Volumn 10, Issue 4, 1998, Pages 226-230

Dosimetry rules for brachytherapy using high dose rate remote afterloading implants

Author keywords

Brachytherapy; Breast implant; High dose rate

Indexed keywords

BRACHYTHERAPY; CLINICAL PRACTICE; CONTROLLED STUDY; DOSIMETRY; FRANCE; HISTOGRAM; HUMAN; IMPLANT; INTERMETHOD COMPARISON; METHODOLOGY; PARAMETER; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; SHORT SURVEY; UNITED KINGDOM;

EID: 0031693203     PISSN: 09366555     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0936-6555(98)80005-8     Document Type: Article
Times cited : (8)

References (7)
  • 2
    • 84907110795 scopus 로고
    • The Paris system in interstitial radiation therapy
    • Pierquin B, Dutreix A, Paine CH, et al. The Paris system in interstitial radiation therapy. Acta Radiol Oncol 1979;17:33-47.
    • (1979) Acta Radiol Oncol , vol.17 , pp. 33-47
    • Pierquin, B.1    Dutreix, A.2    Paine, C.H.3
  • 3
    • 0021239483 scopus 로고
    • Single and double plane implants: A comparison of the Manchester system with the Paris system
    • Gillin MT, Kline RW, Wilson F, et al. Single and double plane implants: a comparison of the Manchester system with the Paris system. Int J Radiat Oncol Biol Phys 1984;10:921-5.
    • (1984) Int J Radiat Oncol Biol Phys , vol.10 , pp. 921-925
    • Gillin, M.T.1    Kline, R.W.2    Wilson, F.3
  • 4
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group no. 43
    • American Association of Physicists in Medicine Task Group 43. Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group no. 43. Med Phys 1995;22:209-34.
    • (1995) Med Phys , vol.22 , pp. 209-234
  • 6
    • 85030344770 scopus 로고    scopus 로고
    • The stepping source as an extension of the Manchester dosimetry system in interstitial brachytherapy
    • Proceedings, British Institute of Radiology Meeting on Brachytherapy 1996
    • Rembowska AME, Hoskin P. The stepping source as an extension of the Manchester dosimetry system in interstitial brachytherapy. Proceedings, British Institute of Radiology Meeting on Brachytherapy 1996. Br J Radiol 1996;69:580.
    • (1996) Br J Radiol , vol.69 , pp. 580
    • Rembowska, A.M.E.1    Hoskin, P.2
  • 7
    • 85030341343 scopus 로고    scopus 로고
    • The stopping source dosimetry system as an extension of the Manchester system
    • Proceedings: ESTRO International Brachytherapy Meeting May 1996.
    • Rembowska AME, Cook M, Hoskin PJ. The stopping source dosimetry system as an extension of the Manchester system. Proceedings: ESTRO International Brachytherapy Meeting May 1996. Radiother Oncol 1996;39(Suppl 1):S25.
    • (1996) Radiother Oncol , vol.39 , Issue.1 SUPPL.
    • Rembowska, A.M.E.1    Cook, M.2    Hoskin, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.