Hemodynamic rounds series II: Hemodynamic evaluation of a stenotic bioprosthetic mitral valve

Author keywords

Hemodynamics; Mitral stenosis

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CLINICAL FEATURE; FEMALE; HEART CATHETERIZATION; HEART HEMODYNAMICS; HEART LEFT ATRIUM PRESSURE; HEART VALVE PROSTHESIS; HUMAN; IMAGE ANALYSIS; LUNG CAPILLARY PRESSURE; MITRAL VALVE REPLACEMENT; MITRAL VALVE STENOSIS; PROSTHESIS FAILURE;

EID: 0031691856     PISSN: 00986569     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0304(199809)45:1<70::AID-CCD17>3.0.CO;2-P     Document Type: Article
Times cited : (2)

References (15)
  • 4
    • 0026024462 scopus 로고
    • Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses
    • Bloomfield P, Wheatley DJ, Prescott RJ, Miller HC: Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses. N Engl J Med 324:573-579, 1991.
    • (1991) N Engl J Med , vol.324 , pp. 573-579
    • Bloomfield, P.1    Wheatley, D.J.2    Prescott, R.J.3    Miller, H.C.4
  • 6
    • 1342309994 scopus 로고
    • Hemodynamic characteristics of the composite strut ball valve prostheses (Starr-Edwards track valves) in patients on anticoagulation
    • McAnulty JH, Morton M, Rahimtoola SH, Kloster FE, Ahuja N, Starr AE: Hemodynamic characteristics of the composite strut ball valve prostheses (Starr-Edwards track valves) in patients on anticoagulation. Circulation [Suppl 1] 58:159-161, 1978.
    • (1978) Circulation , vol.58 , Issue.1 SUPPL. , pp. 159-161
    • McAnulty, J.H.1    Morton, M.2    Rahimtoola, S.H.3    Kloster, F.E.4    Ahuja, N.5    Starr, A.E.6
  • 7
    • 0022413279 scopus 로고
    • A 6 year experience with the St. Jude medical valve: Hemodynamic performance, surgical results, biocompatibility and follow-up
    • Czer LSC, Matloff J, Chaux A, DeRobertis M, Yoganathan A, Gray RJ: A 6 year experience with the St. Jude medical valve: Hemodynamic performance, surgical results, biocompatibility and follow-up. J Am Coll Cardiol 6:904-912, 1985.
    • (1985) J am Coll Cardiol , vol.6 , pp. 904-912
    • Czer, L.S.C.1    Matloff, J.2    Chaux, A.3    DeRobertis, M.4    Yoganathan, A.5    Gray, R.J.6
  • 8
    • 0027446401 scopus 로고
    • Cineradiography for determination of normal and abnormal function in mechanical heart valves
    • Vogel W, Stoll HP, Bay W, Frohlig G, Schieffer H: Cineradiography for determination of normal and abnormal function in mechanical heart valves. Am J Cardiol 71:225-232, 1993.
    • (1993) Am J Cardiol , vol.71 , pp. 225-232
    • Vogel, W.1    Stoll, H.P.2    Bay, W.3    Frohlig, G.4    Schieffer, H.5
  • 11
    • 0026695648 scopus 로고
    • Single-plane transesophageal echocardiography for assessing function of mechanical or bioprosthetic valves in the aortic valve position
    • Karalis DG, Chandrasekaran K, Ross JJ Jr, Micklin A, Brown BM, Ren JF, Mintz GS: Single-plane transesophageal echocardiography for assessing function of mechanical or bioprosthetic valves in the aortic valve position. Am J Cardiol 79:1310-1315, 1992.
    • (1992) Am J Cardiol , vol.79 , pp. 1310-1315
    • Karalis, D.G.1    Chandrasekaran, K.2    Ross J.J., Jr.3    Micklin, A.4    Brown, B.M.5    Ren, J.F.6    Mintz, G.S.7
  • 12
    • 0028020898 scopus 로고
    • Actuarial versus actual risk of porcine structural valve deterioration
    • Grunkemeier GL, Jamieson WRE, Miller DC, Starr A: Actuarial versus actual risk of porcine structural valve deterioration. J Thorac Cardiovasc Surg 108:709-718, 1994.
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 709-718
    • Grunkemeier, G.L.1    Wre, J.2    Miller, D.C.3    Starr, A.4
  • 13
    • 0021354971 scopus 로고
    • Degeneration in porcine bioprosthetic cardiac valves: Incidence of primary tissue failures among 938 bioprostheses at risk
    • Gallo I, Ruiz B, Nistral F, Duran CMG: Degeneration in porcine bioprosthetic cardiac valves: Incidence of primary tissue failures among 938 bioprostheses at risk. Am J Cardiol 53:1061-1065, 1984.
    • (1984) Am J Cardiol , vol.53 , pp. 1061-1065
    • Gallo, I.1    Ruiz, B.2    Nistral, F.3    Cmg, D.4
  • 14
    • 0021831273 scopus 로고
    • Anatomic analysis of removed prosthetic heart valves: Causes of failure of 33 mechanical valve and 58 bioprostheses, 1980 to 1983
    • Scohen EJ, Hobson CE: Anatomic analysis of removed prosthetic heart valves: Causes of failure of 33 mechanical valve and 58 bioprostheses, 1980 to 1983. HumPathol 16:549-559, 1985.
    • (1985) HumPathol , vol.16 , pp. 549-559
    • Scohen, E.J.1    Hobson, C.E.2
  • 15
    • 0024551306 scopus 로고
    • Use of pulmonary capillary wedge pressure to assess severity of mitral stenosis: Is true left atrial pressure needed in this condition?
    • Lange RA, Moore DM Jr, Cigarroa RG, Hillis LD: Use of pulmonary capillary wedge pressure to assess severity of mitral stenosis: Is true left atrial pressure needed in this condition? J Am Coll Cardiol 13:825-831, 1989.
    • (1989) J am Coll Cardiol , vol.13 , pp. 825-831
    • Lange, R.A.1    Moore D.M., Jr.2    Cigarroa, R.G.3    Hillis, L.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.