메뉴 건너뛰기




Volumn 45, Issue 3, 1998, Pages 633-636

Skeletal muscle pH, PCO2, and PO2 during resuscitation of severe hemorrhagic shock

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; OXYGEN;

EID: 0031691244     PISSN: 00225282     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005373-199809000-00043     Document Type: Conference Paper
Times cited : (26)

References (16)
  • 1
    • 0026652861 scopus 로고
    • Elevation of cardiac output and oxygen delivery improves outcome in septic shock
    • Tuchschmidt J, Fried J, Asitz M, et al. Elevation of cardiac output and oxygen delivery improves outcome in septic shock. Chest. 1992;102:216-220.
    • (1992) Chest , vol.102 , pp. 216-220
    • Tuchschmidt, J.1    Fried, J.2    Asitz, M.3
  • 2
    • 0027448345 scopus 로고
    • Relationship between supranormal circulatory values, time delays, and outcome in severely traumatized patients
    • Bishop MH, Shoemaker WC, Appel PL, et al. Relationship between supranormal circulatory values, time delays, and outcome in severely traumatized patients. Crit Care Med. 1993;21:56-63.
    • (1993) Crit Care Med , vol.21 , pp. 56-63
    • Bishop, M.H.1    Shoemaker, W.C.2    Appel, P.L.3
  • 3
    • 0027427633 scopus 로고
    • A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients
    • Boyd O, Grounds M, Bennett ED. A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. JAMA. 1993;270:2699-2707.
    • (1993) JAMA , vol.270 , pp. 2699-2707
    • Boyd, O.1    Grounds, M.2    Bennett, E.D.3
  • 5
    • 0026629772 scopus 로고
    • Incommensurate oxygen consumption in response to maximal oxygen availability predicts postinjury multiple organ failure
    • Moore FA, Haenel JB, Moore EE, et al. Incommensurate oxygen consumption in response to maximal oxygen availability predicts postinjury multiple organ failure. J Trauma. 1992;33:58-67.
    • (1992) J Trauma , vol.33 , pp. 58-67
    • Moore, F.A.1    Haenel, J.B.2    Moore, E.E.3
  • 7
    • 0028867174 scopus 로고
    • Cardiopulmonary hazards of perihepatic packing for major liver injuries
    • Meldrum DR, Moore FA, Moore EE, et al. Cardiopulmonary hazards of perihepatic packing for major liver injuries. Am J Surg. 1995;170:537-542.
    • (1995) Am J Surg , vol.170 , pp. 537-542
    • Meldrum, D.R.1    Moore, F.A.2    Moore, E.E.3
  • 8
    • 0029072611 scopus 로고
    • Critical tissue oxygen tension defines tissue oxygen debt in the isolated hindlimb of the pig during progressive ischemia
    • Hofer SOP, van der Kleij AJ, Grundeman PF, et al. Critical tissue oxygen tension defines tissue oxygen debt in the isolated hindlimb of the pig during progressive ischemia. Crit Care Med. 1995;23:931-938.
    • (1995) Crit Care Med , vol.23 , pp. 931-938
    • Hofer, S.O.P.1    Van Der Kleij, A.J.2    Grundeman, P.F.3
  • 10
    • 0001414201 scopus 로고
    • Blood flow, oxygen tension, oxygen uptake, and oxygen transport in skeletal muscle
    • Stainsby WN, Otis AB. Blood flow, oxygen tension, oxygen uptake, and oxygen transport in skeletal muscle. Am J Physiol. 1964;206:858-866.
    • (1964) Am J Physiol , vol.206 , pp. 858-866
    • Stainsby, W.N.1    Otis, A.B.2
  • 14
    • 0029661879 scopus 로고    scopus 로고
    • 2, and pH during and after hypoxic, ischemic brain insult in dogs
    • 2, and pH during and after hypoxic, ischemic brain insult in dogs. Crit Care Med. 1996; 24:1858-1868.
    • (1996) Crit Care Med , vol.24 , pp. 1858-1868
    • McKinley, B.A.1    Morris, W.P.2    Parmley, C.L.3
  • 15
    • 0030448632 scopus 로고    scopus 로고
    • Gastrointestinal tonometry: A monitor of regional dysoxia
    • Gutierrez G, Brown SD. Gastrointestinal tonometry: a monitor of regional dysoxia. New Horiz. 1996;4:413-419.
    • (1996) New Horiz , vol.4 , pp. 413-419
    • Gutierrez, G.1    Brown, S.D.2
  • 16
    • 0009678808 scopus 로고
    • Continuous arterial blood gas monitoring with transmitted light sensors and LED light sources
    • San Jose, Calif: Society for Photooptical Instrumentation Engineers (SPIE), International Society for Optical Engineering
    • Schlain LA, Spar SM. Continuous arterial blood gas monitoring with transmitted light sensors and LED light sources. Biomedical Fiber Optic Instrumentation. San Jose, Calif: Society for Photooptical Instrumentation Engineers (SPIE), International Society for Optical Engineering; 1994:452-458.
    • (1994) Biomedical Fiber Optic Instrumentation , pp. 452-458
    • Schlain, L.A.1    Spar, S.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.