메뉴 건너뛰기




Volumn 22, Issue 10, 1998, Pages 821-826

Platelet adhesion, contact phase coagulation activation, and C5a generation of polyethylene glycol acid-grafted high flux cellulosic membrane with varieties of grafting amounts

Author keywords

Biocompatibility; Complement activation; Contact phase of blood coagulation; PEG acid grafted high flux cellulosic membrane; Platelet adhesion

Indexed keywords

ADHESION; BIOCOMPATIBILITY; CHAINS; CHEMICAL ACTIVATION; COAGULATION; GRAFTING (CHEMICAL); MEMBRANES; PLATELETS; POLYETHYLENE OXIDES; POLYETHYLENES;

EID: 0031690948     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.1998.06046.x     Document Type: Article
Times cited : (31)

References (20)
  • 2
    • 0028354717 scopus 로고
    • Clinical relevance of biocompatibility
    • Koch KM. Clinical relevance of biocompatibility. Nephrol Dial Transplant 1994;9(Suppl. 2):126-37.
    • (1994) Nephrol Dial Transplant , vol.9 , Issue.2 SUPPL. , pp. 126-137
    • Koch, K.M.1
  • 5
    • 0021198912 scopus 로고
    • Biocompatibility of hemodialysis membranes; Evaluation with C3a anaphylatoxin radioimmunoassays
    • Chenweth DE. Biocompatibility of hemodialysis membranes; Evaluation with C3a anaphylatoxin radioimmunoassays. ASAIO J 1984;7:44-9.
    • (1984) ASAIO J , vol.7 , pp. 44-49
    • Chenweth, D.E.1
  • 6
    • 0028608013 scopus 로고
    • Acute symptoms during and between hemodialysis: The relative role of speed, duration and biocompatibility of dialysis
    • Skroeder NR, Jacobson SH, Lins LE, Kjellstrand CM. Acute symptoms during and between hemodialysis: The relative role of speed, duration and biocompatibility of dialysis. Artif Organs 1994;18:880-7.
    • (1994) Artif Organs , vol.18 , pp. 880-887
    • Skroeder, N.R.1    Jacobson, S.H.2    Lins, L.E.3    Kjellstrand, C.M.4
  • 7
    • 0025325454 scopus 로고
    • Activation of platelet, coagulation and fibrinolysis in patients on long-term hemodialysis: Influence of Cuprophan and polyacrylonitrile
    • Sultan Y, London GM, Goldfarb B, Toulon P, Maechais SJ. Activation of platelet, coagulation and fibrinolysis in patients on long-term hemodialysis: Influence of Cuprophan and polyacrylonitrile. Nephrol Dial Transplant 1990;5:362-8.
    • (1990) Nephrol Dial Transplant , vol.5 , pp. 362-368
    • Sultan, Y.1    London, G.M.2    Goldfarb, B.3    Toulon, P.4    Maechais, S.J.5
  • 8
    • 0000316714 scopus 로고
    • Blood-compatible polymers
    • Ikada Y. Blood-compatible polymers. Adv Polym Sci 1984; 57:103-40.
    • (1984) Adv Polym Sci , vol.57 , pp. 103-140
    • Ikada, Y.1
  • 9
    • 0024652448 scopus 로고
    • Preparation and surface characterization of PEO-grafted and heparin-immobilized polyurethanes
    • Han DK, Park KD, Ahn KD, Jeong SY, Kim YH. Preparation and surface characterization of PEO-grafted and heparin-immobilized polyurethanes. J Biomed Mater Res 1989;23: 87-104.
    • (1989) J Biomed Mater Res , vol.23 , pp. 87-104
    • Han, D.K.1    Park, K.D.2    Ahn, K.D.3    Jeong, S.Y.4    Kim, Y.H.5
  • 10
    • 0026542123 scopus 로고
    • Interaction of poly(ethlene glycol)-grafted cellulosic membranes with proteins and platelets
    • Kishida A, Mishima K, Corretge E, Konishi H, Ikada Y. Interaction of poly(ethlene glycol)-grafted cellulosic membranes with proteins and platelets Biomaterials 1992;13:113-8.
    • (1992) Biomaterials , vol.13 , pp. 113-118
    • Kishida, A.1    Mishima, K.2    Corretge, E.3    Konishi, H.4    Ikada, Y.5
  • 11
    • 0024704991 scopus 로고
    • Efficiency and biocompatibility of a polyethylene glycol grafted cellulosic membrane during hemodialysis
    • Akizawa T, Kino K, Koshikawa S, Ikada Y, Kishida A, Yamashita M, Imamura K. Efficiency and biocompatibility of a polyethylene glycol grafted cellulosic membrane during hemodialysis. ASAIO Trans 1989;35:333-5.
    • (1989) ASAIO Trans , vol.35 , pp. 333-335
    • Akizawa, T.1    Kino, K.2    Koshikawa, S.3    Ikada, Y.4    Kishida, A.5    Yamashita, M.6    Imamura, K.7
  • 12
    • 0025458345 scopus 로고
    • Clinical effects of a polyethylene glycol grafted cellulosic membrane on thrombogenicity and biocompatibility during hemodialysis
    • Akizawa T, Kino K, Kinugasa E, Koshikawa S, Ikada Y, Kishida A, Hatanaka Y, Imamura K. Clinical effects of a polyethylene glycol grafted cellulosic membrane on thrombogenicity and biocompatibility during hemodialysis. ASAIO Trans 1990;36:M640-2.
    • (1990) ASAIO Trans , vol.36
    • Akizawa, T.1    Kino, K.2    Kinugasa, E.3    Koshikawa, S.4    Ikada, Y.5    Kishida, A.6    Hatanaka, Y.7    Imamura, K.8
  • 13
    • 0021251497 scopus 로고
    • Effect of hemodialysis on contact group of coagulation factors, platelet, and leukocytes
    • Vaziri ND, Toohey J, Paule P, Alikhani S, Hung E. Effect of hemodialysis on contact group of coagulation factors, platelet, and leukocytes. Am J Med 1984;77:437-41.
    • (1984) Am J Med , vol.77 , pp. 437-441
    • Vaziri, N.D.1    Toohey, J.2    Paule, P.3    Alikhani, S.4    Hung, E.5
  • 14
    • 0030152417 scopus 로고    scopus 로고
    • Determination of contact phase activation by the measurement of the activity of supernatant and membrane surface-adsorbed Factor XII
    • Matata BM, Courtney JM, Sundaram S, Wark S, Bowry SK, Vineken J, Lowe GDO. Determination of contact phase activation by the measurement of the activity of supernatant and membrane surface-adsorbed Factor XII. J Biomed Mater Res 1996;31:63-70.
    • (1996) J Biomed Mater Res , vol.31 , pp. 63-70
    • Matata, B.M.1    Courtney, J.M.2    Sundaram, S.3    Wark, S.4    Bowry, S.K.5    Vineken, J.6    Lowe, G.D.O.7
  • 15
    • 0042360938 scopus 로고
    • Contact phase activation in dialysis: Relationship between membranes surface properties and activation mechanism
    • Deppish R, Haug U, Mientus W, Gohl H. Contact phase activation in dialysis: Relationship between membranes surface properties and activation mechanism. Blood Purif 1992;10:87.
    • (1992) Blood Purif , vol.10 , pp. 87
    • Deppish, R.1    Haug, U.2    Mientus, W.3    Gohl, H.4
  • 16
    • 0000463084 scopus 로고
    • Orlando, Florida: Academic Press
    • Stolzenbach F. Methods in Enzymology. vol. 9, Orlando, Florida: Academic Press, 1966:278-88.
    • (1966) Methods in Enzymology , vol.9 , pp. 278-288
    • Stolzenbach, F.1
  • 17
    • 0024213218 scopus 로고
    • The behavior of platelets at foreign surfaces
    • Packham MP. The behavior of platelets at foreign surfaces. Proc Soc Exp Biol Med 1988;189:261-74.
    • (1988) Proc Soc Exp Biol Med , vol.189 , pp. 261-274
    • Packham, M.P.1
  • 18
    • 0029239613 scopus 로고
    • Simple method for platelet counting
    • Tamada Y, Kulik EA, Ikada Y. Simple method for platelet counting. Biomaterials 1995;16:259-61.
    • (1995) Biomaterials , vol.16 , pp. 259-261
    • Tamada, Y.1    Kulik, E.A.2    Ikada, Y.3
  • 19
    • 0025981718 scopus 로고
    • Solution technique to incorporate polyethylene oxide and other water-soluble polymers into surfaces of polymeric biomaterials
    • Desai NP, Hubbell JA. Solution technique to incorporate polyethylene oxide and other water-soluble polymers into surfaces of polymeric biomaterials. Biomaterials 1991;12: 144-53.
    • (1991) Biomaterials , vol.12 , pp. 144-153
    • Desai, N.P.1    Hubbell, J.A.2
  • 20
    • 0026577773 scopus 로고
    • Cellulose-based haemodialysis membranes: Biocompatibility and functional performance compared
    • Woffindin C, Hoenich NA, Matthews NS. Cellulose-based haemodialysis membranes: Biocompatibility and functional performance compared. Nephrol Dial Transplant 1992;7: 340-5.
    • (1992) Nephrol Dial Transplant , vol.7 , pp. 340-345
    • Woffindin, C.1    Hoenich, N.A.2    Matthews, N.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.