메뉴 건너뛰기




Volumn 12, Issue 4, 1998, Pages 725-728

Magnetic sensor data acquisition for three-dimensional ultrasound of the orbit

Author keywords

Colour Doppler ultrasonography; Free hand scanning; Optic nerve; Orbit; Three dimensional ultrasound

Indexed keywords

ADULT; ANATOMICAL VARIATION; ARTICLE; B SCAN; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; OPTIC NERVE; ORBIT; SENSOR; THREE DIMENSIONAL IMAGING; ULTRASOUND TRANSDUCER;

EID: 0031684447     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/eye.1998.177     Document Type: Article
Times cited : (8)

References (13)
  • 1
    • 22644436921 scopus 로고    scopus 로고
    • Pictorial review: Ocular ultrasound
    • Fielding JA. Pictorial review: ocular ultrasound. Clin Radiol 1996;51:533-44.
    • (1996) Clin Radiol , vol.51 , pp. 533-544
    • Fielding, J.A.1
  • 2
    • 0024385074 scopus 로고
    • Color Doppler flow imaging of the normal and the abnormal orbit
    • Erickson SJ, Hendrix LE, Massaro BM. Color Doppler flow imaging of the normal and the abnormal orbit. Radiology 1989;173:511-6.
    • (1989) Radiology , vol.173 , pp. 511-516
    • Erickson, S.J.1    Hendrix, L.E.2    Massaro, B.M.3
  • 3
    • 0025796791 scopus 로고
    • Color Doppler imaging of the eye and orbit: Technique and normal vascular anatomy
    • Lieb WE, Cohen SM, Merton DA. Color Doppler imaging of the eye and orbit: technique and normal vascular anatomy. Arch Ophthalmol 1991;109:527-31.
    • (1991) Arch Ophthalmol , vol.109 , pp. 527-531
    • Lieb, W.E.1    Cohen, S.M.2    Merton, D.A.3
  • 4
    • 0030045069 scopus 로고    scopus 로고
    • Color Doppler ultrasound imaging of the eye and orbit
    • Williamson TH, Harris A. Color Doppler ultrasound imaging of the eye and orbit. Surv Ophthalmol 1996;40:255-67.
    • (1996) Surv Ophthalmol , vol.40 , pp. 255-267
    • Williamson, T.H.1    Harris, A.2
  • 5
    • 0025849676 scopus 로고
    • Ultrasonographic, three-dimensional scanning for determination of intraocular tumor volume
    • Copenh
    • Jensen PK, Hansen MK. Ultrasonographic, three-dimensional scanning for determination of intraocular tumor volume. Acta Ophthalmol (Copenh) 1991;69:178-86.
    • (1991) Acta Ophthalmol , vol.69 , pp. 178-186
    • Jensen, P.K.1    Hansen, M.K.2
  • 6
    • 0026702890 scopus 로고
    • Ultrasonographic three-dimensional scanning for determination of intraocular tumor volume
    • Copenh
    • Jensen PK. Ultrasonographic three-dimensional scanning for determination of intraocular tumor volume. Acta Ophthalmol (Copenh) 1992;204(Suppl):23-5.
    • (1992) Acta Ophthalmol , vol.204 , Issue.SUPPL. , pp. 23-25
    • Jensen, P.K.1
  • 8
    • 0029023456 scopus 로고
    • Three-dimensional high-frequency ultrasonic parameter imaging of anterior segment pathology
    • Silverman RH, Rondeau MJ, Lizzi FL, Coleman DJ. Three-dimensional high-frequency ultrasonic parameter imaging of anterior segment pathology. Ophthalmology 1995;102:837-43.
    • (1995) Ophthalmology , vol.102 , pp. 837-843
    • Silverman, R.H.1    Rondeau, M.J.2    Lizzi, F.L.3    Coleman, D.J.4
  • 9
  • 10
    • 0029866342 scopus 로고    scopus 로고
    • Personal computer-based 3-dimensional ultrasound biomicroscopy of the anterior segment
    • Iezzi R, Rosen RB, Tello C, Liebmann J, Walsh JB, Ritch R. Personal computer-based 3-dimensional ultrasound biomicroscopy of the anterior segment. Arch Ophthalmol 1996;114:520-4.
    • (1996) Arch Ophthalmol , vol.114 , pp. 520-524
    • Iezzi, R.1    Rosen, R.B.2    Tello, C.3    Liebmann, J.4    Walsh, J.B.5    Ritch, R.6
  • 11
    • 0028292321 scopus 로고
    • Quantification of atherosclerotic plaques in carotid arteries by three-dimensional ultrasound
    • Delcker A, Diener HC. Quantification of atherosclerotic plaques in carotid arteries by three-dimensional ultrasound. Br J Radiol 1994;67:672-8.
    • (1994) Br J Radiol , vol.67 , pp. 672-678
    • Delcker, A.1    Diener, H.C.2
  • 12
    • 0004441572 scopus 로고    scopus 로고
    • 3D-ultrasound of carotid artery using a sensor as a space orientation
    • Delcker A, Polz H. 3D-ultrasound of carotid artery using a sensor as a space orientation. Cerebrovasc Dis 1996;6(Suppl 3):2.
    • (1996) Cerebrovasc Dis , vol.6 , Issue.3 SUPPL. , pp. 2
    • Delcker, A.1    Polz, H.2
  • 13
    • 0023265833 scopus 로고
    • Standardised A-scan echography in optic nerve disease
    • Gans MS, Byrne SF, Glase JS. Standardised A-scan echography in optic nerve disease. Arch Ophthalmol 1987;105:1232-6.
    • (1987) Arch Ophthalmol , vol.105 , pp. 1232-1236
    • Gans, M.S.1    Byrne, S.F.2    Glase, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.