-
1
-
-
0017800138
-
Dead-time measurements in scintillation cameras under scatter conditions simulating quantitative nuclear cardiography
-
Adams R, Hine G J and Zimmerman C D 1978 Dead-time measurements in scintillation cameras under scatter conditions simulating quantitative nuclear cardiography J. Nucl. Med. 19 538
-
(1978)
J. Nucl. Med.
, vol.19
, pp. 538
-
-
Adams, R.1
Hine, G.J.2
Zimmerman, C.D.3
-
2
-
-
0016191379
-
The influence of true counting rate and the photo-peak fraction of detected events on anger camera dead time
-
Arnold J E, Johnston A S and Pinsky S M 1974 The influence of true counting rate and the photo-peak fraction of detected events on anger camera dead time J. Nucl. Med. 15 412
-
(1974)
J. Nucl. Med.
, vol.15
, pp. 412
-
-
Arnold, J.E.1
Johnston, A.S.2
Pinsky, S.M.3
-
5
-
-
0015395674
-
A correction method for high-count-rate quantitative radionuclide angiography
-
Freedman G S, Kinsella T and Dwyer A 1972 A correction method for high-count-rate quantitative radionuclide angiography Radiology 104 713
-
(1972)
Radiology
, vol.104
, pp. 713
-
-
Freedman, G.S.1
Kinsella, T.2
Dwyer, A.3
-
6
-
-
0010460239
-
Bemerkung zur mathematischen Theorie der Zähler
-
in German
-
Jost R 1947 Bemerkung zur mathematischen Theorie der Zähler Helv. Phys. Acta 20 173 (in German)
-
(1947)
Helv. Phys. Acta
, vol.20
, pp. 173
-
-
Jost, R.1
-
7
-
-
15444356872
-
Dead-time of two multi-head anger cameras in 1-131 dual-energy-window acquisition mode
-
Koral K F, Zasadny K R, Ackerman R J and Ficaro E B 1996 Dead-time of two multi-head anger cameras in 1-131 dual-energy-window acquisition mode J. Nucl. Med. 37 78P
-
(1996)
J. Nucl. Med.
, vol.37
-
-
Koral, K.F.1
Zasadny, K.R.2
Ackerman, R.J.3
Ficaro, E.B.4
-
8
-
-
0024449019
-
Evaluation of a clinical scintillation camera with pulse tail extrapolation electronics
-
Lewellen T K, Brice A N, Pollard K R, Zhu J and Plunkett M E 1989 Evaluation of a clinical scintillation camera with pulse tail extrapolation electronics J. Nucl. Med. 30 1554
-
(1989)
J. Nucl. Med.
, vol.30
, pp. 1554
-
-
Lewellen, T.K.1
Brice, A.N.2
Pollard, K.R.3
Zhu, J.4
Plunkett, M.E.5
-
10
-
-
0024513497
-
The high count rate performance of a two-dimensionally position-sensitive detector for positron emission tomography
-
Mankoff D A, Muehllehner G and Karp J S 1989 The high count rate performance of a two-dimensionally position-sensitive detector for positron emission tomography Phys. Med. Biol. 34 437
-
(1989)
Phys. Med. Biol.
, vol.34
, pp. 437
-
-
Mankoff, D.A.1
Muehllehner, G.2
Karp, J.S.3
-
11
-
-
0016088183
-
The reduction of coincidence loss in radionuclide imaging cameras through the use of composite filters
-
Muehllehner G , Jaszcak R J and Beck R N 1974 The reduction of coincidence loss in radionuclide imaging cameras through the use of composite filters Phys. Med. Biol. 19 504
-
(1974)
Phys. Med. Biol.
, vol.19
, pp. 504
-
-
Muehllehner, G.1
Jaszcak, R.J.2
Beck, R.N.3
-
13
-
-
0016812650
-
Dead-time characteristics of anger cameras
-
Sorenson J A 1975 Dead-time characteristics of anger cameras J. Nucl. Med. 16 284
-
(1975)
J. Nucl. Med.
, vol.16
, pp. 284
-
-
Sorenson, J.A.1
-
15
-
-
0018870223
-
Theoretical studies of image artifacts and counting losses for different photon fluence rates and pulse-height distributions in single-crystal naj(tl) scintillation cameras
-
Strand S and Lamm I 1980 Theoretical studies of image artifacts and counting losses for different photon fluence rates and pulse-height distributions in single-crystal naj(tl) scintillation cameras J. Nucl. Med. 21 264
-
(1980)
J. Nucl. Med.
, vol.21
, pp. 264
-
-
Strand, S.1
Lamm, I.2
-
16
-
-
0017389326
-
The effect of window fraction on the dead-time of anger cameras: Concise communication
-
Wicks R and Blau M 1977 The effect of window fraction on the dead-time of anger cameras: concise communication J. Nucl. Med. 18 732
-
(1977)
J. Nucl. Med.
, vol.18
, pp. 732
-
-
Wicks, R.1
Blau, M.2
|