Volumn 12, Issue 3, 1998, Pages 109-117

Validity and reliability of an isometric dynamometer as an evaluative tool in a rehabilitative clinic

Author keywords

Isometric Strength; Rehabilitation; Reliability; Validity

Indexed keywords

DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DYNAMOMETRY; HUMAN; ISOMETRIC EXERCISE; MUSCLE ISOMETRIC CONTRACTION; MUSCLE STRENGTH; NORMAL HUMAN; REHABILITATION CENTER; REVIEW;

EID: 0031683203     PISSN: 10841288     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (3)

References (25)
  • 1
    • 0023215708 scopus 로고
    • Intrarater reliability of manual muscle testing and hand-held dynametric muscle testing
    • Wadsworth CT, Krishnan R, Sear M, Harrold J, Nielsen DH. Intrarater reliability of manual muscle testing and hand-held dynametric muscle testing. Phys Ther 1987;67:1342-1347.
    • (1987) Phys Ther , vol.67 , pp. 1342-1347
    • Wadsworth, C.T.1    Krishnan, R.2    Sear, M.3    Harrold, J.4    Nielsen, D.H.5
  • 2
    • 0023213664 scopus 로고
    • Clinical reliability of manual muscle testing: Middle trapezius and glutens medius muscle
    • Frese E, Brown M, Norton BJ. Clinical reliability of manual muscle testing: middle trapezius and glutens medius muscle. Phys Ther 1987;67:1072-6.
    • (1987) Phys Ther , vol.67 , pp. 1072-1076
    • Frese, E.1    Brown, M.2    Norton, B.J.3
  • 3
    • 0020725861 scopus 로고
    • Evaluation of isokinetic muscle performance
    • Watkins MP, Harris BA. Evaluation of isokinetic muscle performance. Clin Sports Med 1983;2:37-53.
    • (1983) Clin Sports Med , vol.2 , pp. 37-53
    • Watkins, M.P.1    Harris, B.A.2
  • 4
    • 0026518310 scopus 로고
    • The measurement and prediction of isometric lifting strength in symmetrical and asymmetrical postures
    • Sanchez D, Grieve DW. The measurement and prediction of isometric lifting strength in symmetrical and asymmetrical postures. Ergonomics 1992;35:49-64.
    • (1992) Ergonomics , vol.35 , pp. 49-64
    • Sanchez, D.1    Grieve, D.W.2
  • 5
    • 0027972742 scopus 로고
    • Measurement of low back mobility, isometric strength and isoinertial performance with isostation B-200 Triaxial Dynamometer: Reproducibility of measurement and development of functional indices
    • Rytokoski U, Karppi SL, Puukka P, Soini J, Ronnemaa T. Measurement of low back mobility, isometric strength and isoinertial performance with isostation B-200 Triaxial Dynamometer: Reproducibility of measurement and development of functional indices. J Spinal Disord 1994;7:54-61.
    • (1994) J Spinal Disord , vol.7 , pp. 54-61
    • Rytokoski, U.1    Karppi, S.L.2    Puukka, P.3    Soini, J.4    Ronnemaa, T.5
  • 6
    • 0028314823 scopus 로고
    • Clinical use of neck isometric strength measurement in rehabilitation
    • Ylinen J, Ruusk J. Clinical use of neck isometric strength measurement in rehabilitation. Arch Phys Med Rehabil 1994;75:465-469.
    • (1994) Arch Phys Med Rehabil , vol.75 , pp. 465-469
    • Ylinen, J.1    Ruusk, J.2
  • 7
    • 0027957714 scopus 로고
    • The relation between isometric lifting strength and muscular fitness measures
    • Birch K, Sinnerton S, Reilly T, Lees A. The relation between isometric lifting strength and muscular fitness measures. Ergonomics 1994;37:87-93.
    • (1994) Ergonomics , vol.37 , pp. 87-93
    • Birch, K.1    Sinnerton, S.2    Reilly, T.3    Lees, A.4
  • 8
    • 13144256641 scopus 로고
    • Largo (FL): Bennett Ergonomics Labs, Inc.
    • The Golden Mean Machine reference manual. Largo (FL): Bennett Ergonomics Labs, Inc.; 1993:1-128.
    • (1993) The Golden Mean Machine Reference Manual , pp. 1-128
  • 9
    • 0014052730 scopus 로고
    • The isokinetic concept of exercise
    • Hislop HJ, Perrine JJ. The isokinetic concept of exercise. Phys Ther 1967;47:114-117.
    • (1967) Phys Ther , vol.47 , pp. 114-117
    • Hislop, H.J.1    Perrine, J.J.2
  • 11
    • 0023885867 scopus 로고
    • Reliability of measurements of concentric and eccentric isokinetic loading
    • Tredinnick JT, Duncan PW. Reliability of measurements of concentric and eccentric isokinetic loading. Phys Ther 1988;68:656-659.
    • (1988) Phys Ther , vol.68 , pp. 656-659
    • Tredinnick, J.T.1    Duncan, P.W.2
  • 13
    • 0025002395 scopus 로고
    • The reliability of two different Cybex isokinetic systems
    • Thigpen LK, Blanke D, Lang P. The reliability of two different Cybex isokinetic systems. J Orthop Sports Phys Ther 1990;12:157-162.
    • (1990) J Orthop Sports Phys Ther , vol.12 , pp. 157-162
    • Thigpen, L.K.1    Blanke, D.2    Lang, P.3
  • 14
    • 0025861741 scopus 로고
    • Reliability of an isokinetic dorsiflexion and plantar flexion apparatus
    • Wennerberg D. Reliability of an isokinetic dorsiflexion and plantar flexion apparatus. Am J Sports Med 1991;19:519-522.
    • (1991) Am J Sports Med , vol.19 , pp. 519-522
    • Wennerberg, D.1
  • 16
    • 0019143105 scopus 로고
    • Plantar flexion fatigue and muscle fiber type in power and endurance athletes
    • Clarkson PM, Kroll W, McBride TC. Plantar flexion fatigue and muscle fiber type in power and endurance athletes. Med Sci Sports Exerc 1980;12262-267.
    • (1980) Med Sci Sports Exerc , pp. 12262-12267
    • Clarkson, P.M.1    Kroll, W.2    McBride, T.C.3
  • 17
    • 0027216480 scopus 로고
    • Reliability of isokinetic and isometric measurement of leg strength on men with mental retardation
    • Suomi R, Surburg PR, Lecius P. Reliability of isokinetic and isometric measurement of leg strength on men with mental retardation. Arch Phys Med Rehabil 1993;74:848-852.
    • (1993) Arch Phys Med Rehabil , vol.74 , pp. 848-852
    • Suomi, R.1    Surburg, P.R.2    Lecius, P.3
  • 18
    • 0018128612 scopus 로고
    • Force-time characteristics and fiber composition in human leg extensor muscles
    • Viitasalo JT, Komi PV. Force-time characteristics and fiber composition in human leg extensor muscles. Eur J Appl Physiol 1978;40:7-15.
    • (1978) Eur J Appl Physiol , vol.40 , pp. 7-15
    • Viitasalo, J.T.1    Komi, P.V.2
  • 19
    • 0019295015 scopus 로고
    • Reproducibility of measurements of selected neuromuscular performance variables in man
    • Viitasalo JT, Saukkonen S, Komi PV. Reproducibility of measurements of selected neuromuscular performance variables in man. Electromyogr Clin Neurophysiol 1980;20:487-501.
    • (1980) Electromyogr Clin Neurophysiol , vol.20 , pp. 487-501
    • Viitasalo, J.T.1    Saukkonen, S.2    Komi, P.V.3
  • 20
    • 72849182647 scopus 로고
    • Quantitative muscle testing: Principles and appli-cation to research and clinical services
    • Beasley WC. Quantitative muscle testing: principles and appli-cation to research and clinical services. Arch Phys Med Rehabil 1961;42:398-425.
    • (1961) Arch Phys Med Rehabil , vol.42 , pp. 398-425
    • Beasley, W.C.1
  • 21
  • 22
    • 0025326073 scopus 로고
    • Maximal peak torque as a predictor or peak angular impulse and average power of thigh muscles: An isometric and isokinetic study
    • Kannus VPA, Jarvinen M. Maximal peak torque as a predictor or peak angular impulse and average power of thigh muscles: an isometric and isokinetic study. Int J Sports Med 1990;11:146-149.
    • (1990) Int J Sports Med , vol.11 , pp. 146-149
    • Kannus, V.P.A.1    Jarvinen, M.2
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0027155544 scopus 로고
    • The application of generalizability theory to reliability assessment: A illustration using isometric force measurements
    • Roebroeck ME, Harlaar J, Lankhorst GJ. The application of generalizability theory to reliability assessment: a illustration using isometric force measurements. Phys Ther 1993;73:386-401.
    • (1993) Phys Ther , vol.73 , pp. 386-401
    • Roebroeck, M.E.1    Harlaar, J.2    Lankhorst, G.J.3