메뉴 건너뛰기




Volumn 21, Issue 10, 1998, Pages 1943-1948

The 'SPEM' (Studio Policentrico Elettrocateteri Membrane): A multicenter study on membrane leads

Author keywords

Low energy stimulation; Pacing threshold; Steroid eluting leads

Indexed keywords

DEXAMETHASONE;

EID: 0031660335     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1998.tb00014.x     Document Type: Article
Times cited : (4)

References (17)
  • 1
    • 0026512433 scopus 로고
    • The electrode-tissue interface: The revolutionary role of steroid elution
    • Mond HG, Stokes KB. The electrode-tissue interface: The revolutionary role of steroid elution. PACE 1992; 15:95-107.
    • (1992) PACE , vol.15 , pp. 95-107
    • Mond, H.G.1    Stokes, K.B.2
  • 2
    • 0024273775 scopus 로고
    • Composite electrode tips containing externally placed drug releasing collars
    • Brewer G, Mathivanar R, Skalsky M, et al. Composite electrode tips containing externally placed drug releasing collars. PACE 1988; 11:1760-1769.
    • (1988) PACE , vol.11 , pp. 1760-1769
    • Brewer, G.1    Mathivanar, R.2    Skalsky, M.3
  • 3
    • 2242428032 scopus 로고
    • The impact of steroid eluting leads on long term pacing in the atrium and ventricle
    • Sutton R, Guneri S. The impact of steroid eluting leads on long term pacing in the atrium and ventricle. Eur JCPE 1991; 1:10-15.
    • (1991) Eur JCPE , vol.1 , pp. 10-15
    • Sutton, R.1    Guneri, S.2
  • 4
    • 0027315354 scopus 로고
    • Do steroid-eluting electrodes really have better performance than other state-of-the-art designs?
    • Santini M, De Seta F, The Italian Multicenter Study Group on Low Output Stimulation. Do steroid-eluting electrodes really have better performance than other state-of-the-art designs? PACE 1993; 16:722-728.
    • (1993) PACE , vol.16 , pp. 722-728
    • Santini, M.1    De Seta, F.2
  • 5
    • 0029068786 scopus 로고
    • Long-term results of low energy stimulation: A multicentre study
    • Capucci A, Boriani G, Moracchini PV, et al. Long-term results of low energy stimulation: A multicentre study. Eur JCPE 1995; 5:71-76.
    • (1995) Eur JCPE , vol.5 , pp. 71-76
    • Capucci, A.1    Boriani, G.2    Moracchini, P.V.3
  • 6
    • 0029835108 scopus 로고    scopus 로고
    • The steroid-eluting electrode: A 10-year experience
    • Mond HG, Stokes KB. The steroid-eluting electrode: A 10-year experience. PACE 1996; 19:1016 -1020.
    • (1996) PACE , vol.19 , pp. 1016-1020
    • Mond, H.G.1    Stokes, K.B.2
  • 7
    • 0027959723 scopus 로고
    • Comparison of threshold values between steroid and nonsteroid unipolar membrane leads
    • Svensson O, Karlsson JE, Binner L, et al.. Comparison of threshold values between steroid and nonsteroid unipolar membrane leads. PACE 1994; 17:2008-2011.
    • (1994) PACE , vol.17 , pp. 2008-2011
    • Svensson, O.1    Karlsson, J.E.2    Binner, L.3
  • 8
    • 15644376866 scopus 로고    scopus 로고
    • Elettrodi ad emissione di steroide: Stato dell'arte
    • Rusconi L. Elettrodi ad emissione di steroide: Stato dell'arte. Cardiostimolazione 1996; 14:102-104.
    • (1996) Cardiostimolazione , vol.14 , pp. 102-104
    • Rusconi, L.1
  • 9
    • 0025045994 scopus 로고
    • Stimulation characteristics of a steroid-eluting electrode compared with three conventional electrodes
    • Klein HH, Steinberger J, Kake W. Stimulation characteristics of a steroid-eluting electrode compared with three conventional electrodes. PACE 1990; 13:134-137.
    • (1990) PACE , vol.13 , pp. 134-137
    • Klein, H.H.1    Steinberger, J.2    Kake, W.3
  • 10
    • 0027215372 scopus 로고
    • A randomized comparison of a bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: Implications for long-term programming
    • Gillis AM, Rothschild JM, Hillier K, et al. A randomized comparison of a bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: Implications for long-term programming. PACE 1993; 16:964-970.
    • (1993) PACE , vol.16 , pp. 964-970
    • Gillis, A.M.1    Rothschild, J.M.2    Hillier, K.3
  • 11
    • 0029823909 scopus 로고    scopus 로고
    • Intrapatient comparison of atrial and ventricular sensing, pacing threshold, and impedance: Benefits with steroid-eluting leads
    • Moracchini PV, Tesorieri MC, Giuliani M, et al. Intrapatient comparison of atrial and ventricular sensing, pacing threshold, and impedance: Benefits with steroid-eluting leads. PACE 1996; 19:1482-1487.
    • (1996) PACE , vol.19 , pp. 1482-1487
    • Moracchini, P.V.1    Tesorieri, M.C.2    Giuliani, M.3
  • 12
    • 0024235901 scopus 로고
    • Paired comparisons of steroid-eluting and nonsteroid endocardial pacemaker leads in dogs: Electrical performance and morphologic alterations
    • Radovsky AS, VanVleet JF, Stokes KB, et al. Paired comparisons of steroid-eluting and nonsteroid endocardial pacemaker leads in dogs: Electrical performance and morphologic alterations. PACE 1988; 11:1085-1094.
    • (1988) PACE , vol.11 , pp. 1085-1094
    • Radovsky, A.S.1    VanVleet, J.F.2    Stokes, K.B.3
  • 13
    • 0026440849 scopus 로고
    • Acute and chronic performance of a steroid eluting electrode for ventricular pacing
    • Rhoden WE, Llewellyn MJ, Schofield SW, et al. Acute and chronic performance of a steroid eluting electrode for ventricular pacing. Int J Cardiol 1992; 37:209-212.
    • (1992) Int J Cardiol , vol.37 , pp. 209-212
    • Rhoden, W.E.1    Llewellyn, M.J.2    Schofield, S.W.3
  • 14
    • 0025696084 scopus 로고
    • Drug-eluting collar - A new approach to reducing threshold
    • Wilson A, Cowling R, Mathivanar R, et al. Drug-eluting collar - A new approach to reducing threshold. PACE 1990; 13:1876-1878.
    • (1990) PACE , vol.13 , pp. 1876-1878
    • Wilson, A.1    Cowling, R.2    Mathivanar, R.3
  • 15
    • 0025667759 scopus 로고
    • In vivo elution rate of drug eluting ceramic leads with a reduced dose of dexamethasone sodium phosphate
    • Mathivanar R, Anderson N, Harman D, et al. In vivo elution rate of drug eluting ceramic leads with a reduced dose of dexamethasone sodium phosphate. PACE 1990; 13:1883-1886.
    • (1990) PACE , vol.13 , pp. 1883-1886
    • Mathivanar, R.1    Anderson, N.2    Harman, D.3
  • 16
    • 0028924336 scopus 로고
    • Moderne elektroden mit und ohne steroid: Auswirkungen auf den stimulationsstrom von herzschrittmachern
    • Schuchert A, Kuck KH, Meinertz T. Moderne elektroden mit und ohne steroid: Auswirkungen auf den stimulationsstrom von herzschrittmachern. Z Kardiol 1995; 84:289-295.
    • (1995) Z Kardiol , vol.84 , pp. 289-295
    • Schuchert, A.1    Kuck, K.H.2    Meinertz, T.3
  • 17
    • 0029767427 scopus 로고    scopus 로고
    • Electrophysiological characteristics of bipolar membrane carbon leads with and without steroid elution compared with a conventional carbon and a steroid-eluting platinum lead
    • Wiegand UKH, Potratz J, Lüninghake F, et al. Electrophysiological characteristics of bipolar membrane carbon leads with and without steroid elution compared with a conventional carbon and a steroid-eluting platinum lead. PACE 1996; 19:1155-1161.
    • (1996) PACE , vol.19 , pp. 1155-1161
    • Wiegand, U.K.H.1    Potratz, J.2    Lüninghake, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.