Volumn 23, Issue 3, 1998, Pages 161-168

Do we need Monte Carlo treatment planning for linac based radiosurgery? A case study

Author keywords

Monte Carlo simulation; Radiosurgery; Treatment planning

Indexed keywords

ALGORITHM; COLLIMATOR; DOSE CALCULATION; HUMAN; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIOSURGERY; REVIEW; STEREOTAXIC SURGERY; SYSTEM ANALYSIS; TREATMENT PLANNING;

EID: 0031657748     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-3947(98)00012-0     Document Type: Article
Times cited : (28)

References (10)
  • 2
    • 0344270620 scopus 로고    scopus 로고
    • Monte Carlo dose calculations for radiation treatment planning
    • Mohan R. Monte Carlo dose calculations for radiation treatment planning. Med. Phys. 24:1997;987.
    • (1997) Med. Phys. , vol.24 , pp. 987
    • Mohan, R.1
  • 6
    • 0344466520 scopus 로고    scopus 로고
    • Dose perturbation caused by high density inhomogeneities in small beams in stereotactic radiosurgery
    • Rustgi S.N., Rustgi A.K., Jiang S.B., Ayyangar K.M. Dose perturbation caused by high density inhomogeneities in small beams in stereotactic radiosurgery. Med. Phys. 24:1997;1076.
    • (1997) Med. Phys. , vol.24 , pp. 1076
    • Rustgi, S.N.1    Rustgi, A.K.2    Jiang, S.B.3    Ayyangar, K.M.4
  • 8
    • 0010508143 scopus 로고    scopus 로고
    • Calculation of dosimetric data for small field sizes for 6 MV x-rays using BEAM/DOSXYZ Monte Carlo codes
    • Ayyangar K.M., Jiang S.B. Calculation of dosimetric data for small field sizes for 6 MV x-rays using BEAM/DOSXYZ Monte Carlo codes. Med. Phys. 23:1996;1129.
    • (1996) Med. Phys. , vol.23 , pp. 1129
    • Ayyangar, K.M.1    Jiang, S.B.2
  • 9
    • 0344035392 scopus 로고    scopus 로고
    • Characteristics of radiosurgery beams from a Clinac 1800 accelerator: A Monte Carlo study:
    • In: Leavitt, D.D.; Starkschall, G., editors, Salt Lake City, UT:Medical Physics Publishing;
    • Jiang, S.B.; Ayyangar, K.M. Characteristics of radiosurgery beams from a Clinac 1800 accelerator: a Monte Carlo study: In: Leavitt, D.D.; Starkschall, G., editors, Proceedings of The 12th International Conference on The Use of Computers in Radiation Therapy. Salt Lake City, UT:Medical Physics Publishing; 1997: 86-87.
    • (1997) Proceedings of the 12th International Conference on the Use of Computers in Radiation Therapy. , pp. 86-87
    • Jiang, S.B.1    Ayyangar, K.M.2
  • 10
    • 0344035391 scopus 로고    scopus 로고
    • An investigation on the feasibility of using OMEGA Monte Carlo codes for radiosurgery treatment planning
    • D.D. Leavitt, & G. Starkschall. Salt Lake City, UT: Medical Physics Publishing
    • Ayyangar K.M., Jiang S.B. An investigation on the feasibility of using OMEGA Monte Carlo codes for radiosurgery treatment planning. Leavitt D.D., Starkschall G. Proceedings of The 12th International Conference on The Use of Computers in Radiation Therapy. 1997;88-89 Medical Physics Publishing, Salt Lake City, UT.
    • (1997) Proceedings of the 12th International Conference on the Use of Computers in Radiation Therapy , pp. 88-89
    • Ayyangar, K.M.1    Jiang, S.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.