메뉴 건너뛰기




Volumn 66, Issue 2, 1998, Pages 425-430

Aortic valve replacement with the Biocor PSB stentless xenograft

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA CLAMPING; AORTA STENOSIS; AORTA VALVE REPLACEMENT; ARTICLE; ASCENDING AORTA; CARDIOPULMONARY BYPASS; CEREBROVASCULAR ACCIDENT; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; FEMALE; FOLLOW UP; HEART VALVE BIOPROSTHESIS; HUMAN; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REPLACEMENT; PRIORITY JOURNAL; QUALITY OF LIFE; SURGICAL MORTALITY; SURVIVAL RATE;

EID: 0031657492     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-4975(98)00345-2     Document Type: Article
Times cited : (6)

References (20)
  • 1
    • 0025191277 scopus 로고
    • Aortic valve replacement with stentless porcine aortic bioprosthesis
    • David T.E., Pollick C., Bos J. Aortic valve replacement with stentless porcine aortic bioprosthesis. J Thorac Cardiovasc Surg. 99:1990;113-118.
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 113-118
    • David, T.E.1    Pollick, C.2    Bos, J.3
  • 2
    • 0028249804 scopus 로고
    • The O'Brien-Angell stentless valve: Early results of 100 implants
    • Hvass U., Chatel D., Ouroudji M., et al. The O'Brien-Angell stentless valve early results of 100 implants . Eur J Cardiothorac Surg. 8:1994;384-387.
    • (1994) Eur J Cardiothorac Surg , vol.8 , pp. 384-387
    • Hvass, U.1    Chatel, D.2    Ouroudji, M.3
  • 3
    • 0028673425 scopus 로고
    • The new stentless aortic valve: Clinical results in the first 100 patients
    • Vrandecic M., Gontjio B.F., Fantini F.A., et al. The new stentless aortic valve clinical results in the first 100 patients . J Cardiovasc Surg. 35:1994;31-34.
    • (1994) J Cardiovasc Surg , vol.35 , pp. 31-34
    • Vrandecic, M.1    Gontjio, B.F.2    Fantini, F.A.3
  • 5
    • 0029872074 scopus 로고    scopus 로고
    • Hemodynamic performance of the PRIMA Edwards stentless aortic xenograft: Early results of a multicenter clinical trial
    • Dossche K., Vanermen H., Daenen W., Pillai R., Konertz W. Hemodynamic performance of the PRIMA Edwards stentless aortic xenograft early results of a multicenter clinical trial . Thorac Cardiovasc Surg. 44:1996;11-14.
    • (1996) Thorac Cardiovasc Surg , vol.44 , pp. 11-14
    • Dossche, K.1    Vanermen, H.2    Daenen, W.3    Pillai, R.4    Konertz, W.5
  • 7
    • 0029093740 scopus 로고
    • Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position
    • Jin X.J., Gibson D.K., Yacoub M.H., Pepper J.R. Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position. Ann Thorac Surg. 60:1995;S395-S401.
    • (1995) Ann Thorac Surg , vol.60
    • Jin, X.J.1    Gibson, D.K.2    Yacoub, M.H.3    Pepper, J.R.4
  • 8
    • 0029118130 scopus 로고
    • Aortic valve replacement: Is the stentless xenograft an alternative to homograft? Early results of a randomized study
    • Gross C., Harringer W., Mair R., et al. Aortic valve replacement: is the stentless xenograft an alternative to homograft? Early results of a randomized study. Ann Thorac Surg. 60:1995;S418-S421.
    • (1995) Ann Thorac Surg , vol.60
    • Gross, C.1    Harringer, W.2    Mair, R.3
  • 9
    • 0026464865 scopus 로고
    • Stentless porcine and pericardial valve in aortic position
    • Casabona R., De Paulis R., Zattera G.F., et al. Stentless porcine and pericardial valve in aortic position. Ann Thorac Surg. 54:1992;681-685.
    • (1992) Ann Thorac Surg , vol.54 , pp. 681-685
    • Casabona, R.1    De Paulis, R.2    Zattera, G.F.3
  • 11
    • 0000336139 scopus 로고
    • Regression models and life tables
    • Cox D.R. Regression models and life tables. J R Stat Soc B. 34:1972;187.
    • (1972) J R Stat Soc B , vol.34 , pp. 187
    • Cox, D.R.1
  • 12
    • 0020622216 scopus 로고
    • Role of mechanical stress in calcification of aortic bioprosthetic valve
    • Thubrikar M., Deck J.D., Aouad J., Nolan S.P. Role of mechanical stress in calcification of aortic bioprosthetic valve. J Thorac Cardiovasc Surg. 86:1983;115-125.
    • (1983) J Thorac Cardiovasc Surg , vol.86 , pp. 115-125
    • Thubrikar, M.1    Deck, J.D.2    Aouad, J.3    Nolan, S.P.4
  • 13
    • 0018101376 scopus 로고
    • Fatigue-induced damage in glutaraldehyde-preserved heart valve tissue
    • Broom N.D. Fatigue-induced damage in glutaraldehyde-preserved heart valve tissue. J Thorac Cardiovasc Surg. 76:1978;202-211.
    • (1978) J Thorac Cardiovasc Surg , vol.76 , pp. 202-211
    • Broom, N.D.1
  • 17
    • 0030246897 scopus 로고    scopus 로고
    • Effects of valve substitute on changes in left ventricular function and hypertrophy after aortic valve replacement
    • Jin X.Y., Zhang Z.M., Gibson D.K., Yacoub M.H., Pepper J.R. Effects of valve substitute on changes in left ventricular function and hypertrophy after aortic valve replacement. Ann Thorac Surg. 63:1996;683-690.
    • (1996) Ann Thorac Surg , vol.63 , pp. 683-690
    • Jin, X.Y.1    Zhang, Z.M.2    Gibson, D.K.3    Yacoub, M.H.4    Pepper, J.R.5
  • 19
    • 0029016342 scopus 로고
    • The Toronto SPV bioprosthesis: One-year results in 100 patients
    • Mohr F.W., Walther T., Baryalei M., et al. The Toronto SPV bioprosthesis one-year results in 100 patients . Ann Thorac Surg. 60:1995;171-175.
    • (1995) Ann Thorac Surg , vol.60 , pp. 171-175
    • Mohr, F.W.1    Walther, T.2    Baryalei, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.