메뉴 건너뛰기




Volumn 87, Issue 3, 1998, Pages 614-618

The effects of maternal position during induction of combined spinal- epidural anesthesia for cesarean delivery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANESTHESIA COMPLICATION; ARTICLE; CESAREAN SECTION; CLINICAL ARTICLE; CONTROLLED STUDY; EPIDURAL ANESTHESIA; FEMALE; HUMAN; HYPOTENSION; OBSTETRIC ANESTHESIA; PATIENT POSITIONING; PRIORITY JOURNAL; RISK ASSESSMENT; SPINAL ANESTHESIA;

EID: 0031654611     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/00000539-199809000-00023     Document Type: Article
Times cited : (51)

References (21)
  • 2
    • 0004662046 scopus 로고
    • Identifying the epidural space
    • Norris MC, eds. Philadelphia: JB Lippincott
    • Reynolds F. Identifying the epidural space. In: Norris MC, eds. Obstetric Anesthesia. Philadelphia: JB Lippincott, 1993:307-18.
    • (1993) Obstetric Anesthesia , pp. 307-318
    • Reynolds, F.1
  • 5
    • 0017281919 scopus 로고
    • Effect of the left lateral recumbent position compared with the supine and upright positions on placental blood flow in normal late pregnancy
    • Suonio S, Simpanen AL, Olkkonen H, Haring P. Effect of the left lateral recumbent position compared with the supine and upright positions on placental blood flow in normal late pregnancy. Ann Clin Res 1976;8:22-6.
    • (1976) Ann Clin Res , vol.8 , pp. 22-26
    • Suonio, S.1    Simpanen, A.L.2    Olkkonen, H.3    Haring, P.4
  • 7
    • 0009864290 scopus 로고
    • Which position is more comfortable for the parturient during identification of the epidural space?
    • Vincent RD, Chestnut DH. Which position is more comfortable for the parturient during identification of the epidural space? Int J Obstet Anesth 1991;1:9-11.
    • (1991) Int J Obstet Anesth , vol.1 , pp. 9-11
    • Vincent, R.D.1    Chestnut, D.H.2
  • 8
    • 0028905422 scopus 로고
    • Combined spinal and epidural anesthesia
    • Felsby S, Palle J. Combined spinal and epidural anesthesia. Anesth Analg 1995;80:821-6.
    • (1995) Anesth Analg , vol.80 , pp. 821-826
    • Felsby, S.1    Palle, J.2
  • 10
    • 0028952182 scopus 로고
    • Parturient's posture during epidural puncture affects the distance from skin to epidural space
    • Hamza J, Smida M, Benhamou D, Cohen SE. Parturient's posture during epidural puncture affects the distance from skin to epidural space. J Clin Anesth 1995;7:1-4.
    • (1995) J Clin Anesth , vol.7 , pp. 1-4
    • Hamza, J.1    Smida, M.2    Benhamou, D.3    Cohen, S.E.4
  • 11
    • 0003238108 scopus 로고
    • Spinal, epidural, and caudal anesthesia: Anatomy, physiology and technique
    • Chestnut DH, ed. St. Louis: Mosby Yearbook
    • Brown DL. Spinal, epidural, and caudal anesthesia: anatomy, physiology and technique. In: Chestnut DH, ed. Obstetric anesthesia principles and practice. St. Louis: Mosby Yearbook, 1994: 181-201.
    • (1994) Obstetric Anesthesia Principles and Practice , pp. 181-201
    • Brown, D.L.1
  • 12
    • 0027209528 scopus 로고
    • A reevaluation of the role of crystalloid preload in the prevention of hypotension associated with spinal anesthesia for elective cesarean section
    • Rout CC, Rocke DA, Levin J, et al. A reevaluation of the role of crystalloid preload in the prevention of hypotension associated with spinal anesthesia for elective cesarean section. Anesthesiology 1993;79:262-9.
    • (1993) Anesthesiology , vol.79 , pp. 262-269
    • Rout, C.C.1    Rocke, D.A.2    Levin, J.3
  • 13
    • 0030017138 scopus 로고    scopus 로고
    • The effects of varying volumes of crystalloid administration before cesarean delivery on maternal hemodynamics and colloid osmotic pressure
    • Park GE, Hauch MA, Curlin F, et al. The effects of varying volumes of crystalloid administration before cesarean delivery on maternal hemodynamics and colloid osmotic pressure. Anesth Analg 1996;83:299-303.
    • (1996) Anesth Analg , vol.83 , pp. 299-303
    • Park, G.E.1    Hauch, M.A.2    Curlin, F.3
  • 14
    • 0027488660 scopus 로고
    • Posture and the spread of hyperbaric bupivacaine in parturients using the combined spinal epidural technique: Report of investigation
    • Patel M, Samsoon G, Swami A, Morgan B. Posture and the spread of hyperbaric bupivacaine in parturients using the combined spinal epidural technique: report of investigation. Can J Anaesth 1993;40:943-6.
    • (1993) Can J Anaesth , vol.40 , pp. 943-946
    • Patel, M.1    Samsoon, G.2    Swami, A.3    Morgan, B.4
  • 15
    • 0014678234 scopus 로고
    • Maternal cardiovascular dynamics: The influence of gestational age on the maternal cardiovascular response to posture and exercise
    • Ueland K, Novy MJ, Peterson EN, Metcalfe J. Maternal cardiovascular dynamics: the influence of gestational age on the maternal cardiovascular response to posture and exercise. Am J Obstet Gynecol 1969;104:856-64.
    • (1969) Am J Obstet Gynecol , vol.104 , pp. 856-864
    • Ueland, K.1    Novy, M.J.2    Peterson, E.N.3    Metcalfe, J.4
  • 16
    • 0021333455 scopus 로고
    • Prophylactic use of droperidol for the control of nausea and vomiting during spinal anesthesia for cesarean section
    • Santos AC, Datta S. Prophylactic use of droperidol for the control of nausea and vomiting during spinal anesthesia for cesarean section. Anesth Analg 1984;63:85-7.
    • (1984) Anesth Analg , vol.63 , pp. 85-87
    • Santos, A.C.1    Datta, S.2
  • 17
    • 0023449899 scopus 로고
    • The incidence and neonatal effects of maternal hypotension during epidural anesthesia for cesarean section
    • Brizgys RV, Dailey PA, Shnider SM, et al. The incidence and neonatal effects of maternal hypotension during epidural anesthesia for cesarean section. Anesthesiology 1987;67:782-7.
    • (1987) Anesthesiology , vol.67 , pp. 782-787
    • Brizgys, R.V.1    Dailey, P.A.2    Shnider, S.M.3
  • 18
    • 0000577226 scopus 로고
    • Influence of postspinal hypotension on the fetal electrocardiogram
    • Ebner H, Barcohana J, Bartoshuk AK. Influence of postspinal hypotension on the fetal electrocardiogram. Am J Obstet Gynecol 1960;80:569-72.
    • (1960) Am J Obstet Gynecol , vol.80 , pp. 569-572
    • Ebner, H.1    Barcohana, J.2    Bartoshuk, A.K.3
  • 19
    • 0022271272 scopus 로고
    • Placental transfer of ephedrine does not affect neonatal outcome
    • Hughes SC, Ward MMG, Levinson G, et al. Placental transfer of ephedrine does not affect neonatal outcome. Anesthesiology 1985;63:217-9.
    • (1985) Anesthesiology , vol.63 , pp. 217-219
    • Hughes, S.C.1    Ward, M.M.G.2    Levinson, G.3
  • 20
    • 0025068729 scopus 로고
    • Does ephedrine influence newborn neurobehavioural responses and spectral EEG when used to prevent maternal hypotension during caesarean section?
    • Kangas-Saarela T, Hollmen AI, Tolonen U, et al. Does ephedrine influence newborn neurobehavioural responses and spectral EEG when used to prevent maternal hypotension during caesarean section? Acta Anaesthesiol Scand 1990;34:8-16.
    • (1990) Acta Anaesthesiol Scand , vol.34 , pp. 8-16
    • Kangas-Saarela, T.1    Hollmen, A.I.2    Tolonen, U.3
  • 21
    • 0020063353 scopus 로고
    • Prophylactic intramuscular ephedrine before epidural anaesthesia for cesarean section: Efficacy and actions on the foetus and newborn
    • Rolbin AH, Cole AFD, Hew EM, et al. Prophylactic intramuscular ephedrine before epidural anaesthesia for cesarean section: efficacy and actions on the foetus and newborn. Can Anaesth Soc J 1982;29:148-53.
    • (1982) Can Anaesth Soc J , vol.29 , pp. 148-153
    • Rolbin, A.H.1    Cole, A.F.D.2    Hew, E.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.