메뉴 건너뛰기




Volumn 13, Issue 1, 1998, Pages 212-217

Conforming and non-conforming current for attributing steady state power quality problems

Author keywords

Conforming; Direction; Distribution; Flicker; Harmonics; Measurement; Origin; Power quality; Unbalance

Indexed keywords

ELECTRIC DISTORTION; ELECTRIC LOADS; ELECTRIC POWER DISTRIBUTION; ELECTRIC POWER MEASUREMENT; ELECTRIC WAVEFORMS; HARMONIC ANALYSIS; PERTURBATION TECHNIQUES;

EID: 0031647118     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/61.660880     Document Type: Article
Times cited : (71)

References (14)
  • 1
    • 33747361229 scopus 로고
    • Utilities Coordinated Research Inc., Report for committee for project no. 10
    • Stanley Stokes, "Visual perception and tolerance of flicker", Utilities Coordinated Research Inc., Report for committee for project no. 10, 1937.
    • (1937) Visual Perception and Tolerance of Flicker
    • Stokes, S.1
  • 2
    • 0004010936 scopus 로고
    • Stars in a Circle Publication, Lafayette, Indiana
    • G.T. Heydt, Electric Power Quality, Stars in a Circle Publication, Lafayette, Indiana 1991.
    • (1991) Electric Power Quality
    • Heydt, G.T.1
  • 5
    • 0012085364 scopus 로고
    • Chairman, Union Internationale d'Électrothermie, Groupe de travail Perturbations, Rapport Tour Atlantique, Cedex 6, 92080 Paris-la-Défense
    • C. Mirra, Chairman, "Flicker measurement and evaluation", Union Internationale d'Électrothermie, Groupe de travail Perturbations, Rapport 1986, Tour Atlantique, Cedex 6, 92080 Paris-la-Défense,
    • (1986) Flicker Measurement and Evaluation
    • Mirra, C.1
  • 10
  • 12
    • 33747442043 scopus 로고
    • Survey of Techniques to Identify Source of Power Quality disturbances
    • May
    • Glenn Hatanaka, "Survey of Techniques to Identify Source of Power Quality disturbances," CEA SD-22OE Position Paper, May 1993.
    • (1993) CEA SD-22OE Position Paper
    • Hatanaka, G.1
  • 13
    • 0025406822 scopus 로고
    • A Neural Network approach to the detection of Incipient Faults on Power Distribution Feeders
    • April
    • S. Ebron, D.L. Lubkeman and M. White, "A Neural Network approach to the detection of Incipient Faults on Power Distribution Feeders," IEEE Transactions on Power Delivery, Vol 5, No.2, pp. 905-914, April 1990.
    • (1990) IEEE Transactions on Power Delivery , vol.5 , Issue.2 , pp. 905-914
    • Ebron, S.1    Lubkeman, D.L.2    White, M.3
  • 14
    • 0141480108 scopus 로고
    • How much Harmonics is your Responsibility?
    • July August
    • K. Srinivasan, "How much Harmonics is your Responsibility?", Power Quality Assurance, July August 1995, pp62-65.
    • (1995) Power Quality Assurance , pp. 62-65
    • Srinivasan, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.