Volumn 19, Issue 3, 1998, Pages 141-148

Drainage vent systems: Investigation and analysis of air pressure regime

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0031633301     PISSN: 01436244     EISSN: None     Source Type: Journal    
DOI: 10.1177/014362449801900305     Document Type: Article
Times cited : (15)

References (8)
  • 1
    • 0026899310 scopus 로고
    • Air pressure transient propagation in building drainage vent systems, an application of unsteady flow analysis
    • Swaffield J A and Campbell D P Air pressure transient propagation in building drainage vent systems, an application of unsteady flow analysis Building Environ. 27(3) 357-365 (1992)
    • (1992) Building Environ. , vol.27 , Issue.3 , pp. 357-365
    • Swaffield, J.A.1    Campbell, D.P.2
  • 2
    • 0026940975 scopus 로고
    • Numerical modelling of air pressure transient propagation in building drainage systems, including the influence of mechanical boundary conditions
    • Swaffield J A and Campbell D P Numerical modelling of air pressure transient propagation in building drainage systems, including the influence of mechanical boundary conditions Building Environ. 27(4) 455-467 (1992)
    • (1992) Building Environ. , vol.27 , Issue.4 , pp. 455-467
    • Swaffield, J.A.1    Campbell, D.P.2
  • 3
    • 0029220551 scopus 로고
    • The simulation of air pressure propagation in building drainage and vent systems
    • Swaffield J A and Campbell D P The simulation of air pressure propagation in building drainage and vent systems Building Environ. 30(1) 115-127 (1995)
    • (1995) Building Environ. , vol.30 , Issue.1 , pp. 115-127
    • Swaffield, J.A.1    Campbell, D.P.2
  • 4
    • 0346151913 scopus 로고
    • Capacity of stacks in sanitary drainage systems for buildings
    • Washington DC: US Department of Commerce, National Bureau of Standards
    • Wyly R S and Eaton H N Capacity of stacks in sanitary drainage systems for buildings NBS Monograph 3 (Washington DC: US Department of Commerce, National Bureau of Standards) (1961)
    • (1961) NBS Monograph , vol.3
    • Wyly, R.S.1    Eaton, H.N.2
  • 5
    • 25544432960 scopus 로고
    • The effect of stack length on the air flow in drainage stacks
    • Garston, UK: Building Research Establishment
    • Pink B J The effect of stack length on the air flow in drainage stacks BRE Current Paper 38/73 (Garston, UK: Building Research Establishment) (1973)
    • (1973) BRE Current Paper , vol.38-73
    • Pink, B.J.1
  • 6
    • 36149025564 scopus 로고
    • On physically similar systems: Illustrations of the use of dimensional euations
    • Buckingham E On physically similar systems: Illustrations of the use of dimensional euations Phys. Rev. Series 2 4 345 (1914)
    • (1914) Phys. Rev. Series 2 , vol.4 , pp. 345
    • Buckingham, E.1
  • 7
    • 4243939610 scopus 로고
    • Laboratory measurements of pressure drop factors for branch discharges in vertical drainage stacks
    • Garston, UK: Building Research Establishment
    • O'Sullivan E F Laboratory measurements of pressure drop factors for branch discharges in vertical drainage stacks BRE Note N3/74 (Garston, UK: Building Research Establishment) (1974)
    • (1974) BRE Note N , vol.3-74
    • O'Sullivan, E.F.1