메뉴 건너뛰기




Volumn 12, Issue 1, 1998, Pages 21-26

Fracture Site Motion with Ilizarov and "Hybrid" External Fixation

Author keywords

"Hybrid,"; Biomechanical; External fixator; Fracture fixation; Ilizarov; Trauma

Indexed keywords

ARTICLE; BIOMECHANICS; COMPARATIVE STUDY; EXTERNAL FIXATOR; FRACTURE; FRACTURE FIXATION; MOTION;

EID: 0031606479     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-199801000-00004     Document Type: Article
Times cited : (43)

References (46)
  • 1
    • 0025353398 scopus 로고
    • The effects of physiologic dynamic compression on bone healing under external fixation
    • Aro HT, Kelly PJ, Lewallen DG, Chao EYS. The effects of physiologic dynamic compression on bone healing under external fixation. Clin Orthop 1990;256:260-273.
    • (1990) Clin Orthop , vol.256 , pp. 260-273
    • Aro, H.T.1    Kelly, P.J.2    Lewallen, D.G.3    Chao, E.Y.S.4
  • 2
    • 0026675077 scopus 로고
    • Mechanical considerations in using tensioned wires in a transosseous external fixation system
    • Aronsen J, Harp JH. Mechanical considerations in using tensioned wires in a transosseous external fixation system. Clin Orthop 1992;280:23-29.
    • (1992) Clin Orthop , vol.280 , pp. 23-29
    • Aronsen, J.1    Harp, J.H.2
  • 3
    • 0024517307 scopus 로고
    • Plate versus external fixation in severe open tibial shaft fractures
    • Bach AW, Hansen ST. Plate versus external fixation in severe open tibial shaft fractures. Clin Orthop 1989;241:89-93.
    • (1989) Clin Orthop , vol.241 , pp. 89-93
    • Bach, A.W.1    Hansen, S.T.2
  • 4
    • 0029852787 scopus 로고    scopus 로고
    • Hybrid external fixation in the treatment of tibial plafond fractures
    • Barbieri R, Schenk R, Koval K, Aurori K, Aurori B. Hybrid external fixation in the treatment of tibial plafond fractures. Clin Orthop 1996;332:16-22.
    • (1996) Clin Orthop , vol.332 , pp. 16-22
    • Barbieri, R.1    Schenk, R.2    Koval, K.3    Aurori, K.4    Aurori, B.5
  • 5
    • 0024603829 scopus 로고
    • Unilateral external fixation: Methods to increase and reduce frame stiffness
    • Behrens F. Johnson W. Unilateral external fixation: methods to increase and reduce frame stiffness. Clin Orthop 1989;241:48-56.
    • (1989) Clin Orthop , vol.241 , pp. 48-56
    • Behrens, F.1    Johnson, W.2
  • 6
    • 0020561952 scopus 로고
    • Bending stiffness in unilateral and bilateral fixator frames
    • Behrens F, Johnson WD, Koch TW, Kovacevic N. Bending stiffness in unilateral and bilateral fixator frames. Clin Orthop 1983;178:103-110.
    • (1983) Clin Orthop , vol.178 , pp. 103-110
    • Behrens, F.1    Johnson, W.D.2    Koch, T.W.3    Kovacevic, N.4
  • 7
    • 0028606019 scopus 로고
    • Mechanical performance of the Monticelli-Spinelli external fixation system
    • Caja VL, Larsson S, Kim W, Chao EYS. Mechanical performance of the Monticelli-Spinelli external fixation system. Clin Orthop 1994;309:257-266.
    • (1994) Clin Orthop , vol.309 , pp. 257-266
    • Caja, V.L.1    Larsson, S.2    Kim, W.3    Chao, E.Y.S.4
  • 8
    • 0026674037 scopus 로고
    • Biomechanics of the Ilizarov fixator for fracture fixation
    • Calhoun JH, Li F, Ledbetter BR, Gill CA. Biomechanics of the Ilizarov fixator for fracture fixation. Clin Orthop 1992;280:15-22.
    • (1992) Clin Orthop , vol.280 , pp. 15-22
    • Calhoun, J.H.1    Li, F.2    Ledbetter, B.R.3    Gill, C.A.4
  • 9
    • 0024601762 scopus 로고
    • The effect of rigidity on fracture healing in external fixation
    • Chao EYS, Aro HT, Lewallen DG, Kelly PJ. The effect of rigidity on fracture healing in external fixation. Clin Orthop 1989;241:24-35.
    • (1989) Clin Orthop , vol.241 , pp. 24-35
    • Chao, E.Y.S.1    Aro, H.T.2    Lewallen, D.G.3    Kelly, P.J.4
  • 10
    • 0022336497 scopus 로고
    • The effect of external skeletal fixation on bone healing and bone blood supply
    • Court-Brown CM. The effect of external skeletal fixation on bone healing and bone blood supply. Clin Orthop 1985;210:278-289.
    • (1985) Clin Orthop , vol.210 , pp. 278-289
    • Court-Brown, C.M.1
  • 11
    • 0028998766 scopus 로고
    • Tibial pilon fractures: A comparative clinical study of management techniques and results
    • Crutchfield EH, Seligson DS, Henry SL, Warnholtz A. Tibial pilon fractures: a comparative clinical study of management techniques and results. Orthopaedics 1995;18:613-617.
    • (1995) Orthopaedics , vol.18 , pp. 613-617
    • Crutchfield, E.H.1    Seligson, D.S.2    Henry, S.L.3    Warnholtz, A.4
  • 12
    • 0023877831 scopus 로고
    • Severe open tibial fractures: Results treating 202 injuries with external fixation
    • Edwards CC, Simmons SC, Browner BD, Weigel MC. Severe open tibial fractures: results treating 202 injuries with external fixation. Clin Orthop 1988;240:98-114.
    • (1988) Clin Orthop , vol.240 , pp. 98-114
    • Edwards, C.C.1    Simmons, S.C.2    Browner, B.D.3    Weigel, M.C.4
  • 14
    • 0023876739 scopus 로고
    • External fixation of fractures of the tibia: Clinical experience of a new device
    • Evans G, McLaren M, Shearer JR. External fixation of fractures of the tibia: clinical experience of a new device. Injury 1988;19:73-76.
    • (1988) Injury , vol.19 , pp. 73-76
    • Evans, G.1    McLaren, M.2    Shearer, J.R.3
  • 15
    • 0024516018 scopus 로고
    • A biomechanical analysis of the Ilizarov external fixator
    • Fleming B, Paley D, Kristiansen T, Pope M. A biomechanical analysis of the Ilizarov external fixator. Clin Orthop 1989;241:95-105.
    • (1989) Clin Orthop , vol.241 , pp. 95-105
    • Fleming, B.1    Paley, D.2    Kristiansen, T.3    Pope, M.4
  • 16
    • 0025388840 scopus 로고
    • Stiffness characteristics of the circular Ilizarov device as opposed to conventional external fixators
    • Gasser B, Roman B, Wyder D, Schneider E. Stiffness characteristics of the circular Ilizarov device as opposed to conventional external fixators. J Biomech Eng 1990;112(1):15-21.
    • (1990) J Biomech Eng , vol.112 , Issue.1 , pp. 15-21
    • Gasser, B.1    Roman, B.2    Wyder, D.3    Schneider, E.4
  • 17
    • 0030006075 scopus 로고    scopus 로고
    • Hybrid external fixation of comminuted tibial plateau fractures
    • Gaudinez RF, Mallik AR, Szporn M. Hybrid external fixation of comminuted tibial plateau fractures. Clin Orthop 1996;328:203-210.
    • (1996) Clin Orthop , vol.328 , pp. 203-210
    • Gaudinez, R.F.1    Mallik, A.R.2    Szporn, M.3
  • 18
    • 0021907952 scopus 로고
    • External fixation of canine tibial osteotomies. Compression compared with no compression
    • Hart MB, Wu J, Chao EYS, Kelly PJ. External fixation of canine tibial osteotomies. Compression compared with no compression. J Bone Joint Surg 1985;67A:598-605.
    • (1985) J Bone Joint Surg , vol.67 A , pp. 598-605
    • Hart, M.B.1    Wu, J.2    Chao, E.Y.S.3    Kelly, P.J.4
  • 19
    • 0022579452 scopus 로고
    • Guidelines for external fixation frame rigidity and stresses
    • Huiskes R, Chao EYS. Guidelines for external fixation frame rigidity and stresses. J Orthop Res 1986;4:68-75.
    • (1986) J Orthop Res , vol.4 , pp. 68-75
    • Huiskes, R.1    Chao, E.Y.S.2
  • 20
    • 0014522736 scopus 로고
    • The replacement of long bone defects by lengthening distraction osteotomy of one of the fragments
    • Ilizarov GA, Ledyaev VI. The replacement of long bone defects by lengthening distraction osteotomy of one of the fragments. Vestnik Khururgii 1969;102(6):77-84.
    • (1969) Vestnik Khururgii , vol.102 , Issue.6 , pp. 77-84
    • Ilizarov, G.A.1    Ledyaev, V.I.2
  • 21
    • 0028107083 scopus 로고
    • Comparison of the mechanical performance of three types of unilateral, dynamizable external fixators
    • Jaskulka RA, Egkher E, Wielke B. Comparison of the mechanical performance of three types of unilateral, dynamizable external fixators. Arch Orthop Trauma Surg 1994;113:271-275.
    • (1994) Arch Orthop Trauma Surg , vol.113 , pp. 271-275
    • Jaskulka, R.A.1    Egkher, E.2    Wielke, B.3
  • 22
    • 0026848937 scopus 로고
    • A method for the intravital measurement of interspinous kinematics
    • Kaigle AM, Pope M, Fleming B, Hansen T. A method for the intravital measurement of interspinous kinematics. J Biomech 1992;25:451-456.
    • (1992) J Biomech , vol.25 , pp. 451-456
    • Kaigle, A.M.1    Pope, M.2    Fleming, B.3    Hansen, T.4
  • 23
    • 0028197471 scopus 로고
    • The Orthofix external fixator for fractures of long bones
    • Kim NH, Hahn SB, Park HW, Yang IH. The Orthofix external fixator for fractures of long bones. Int Orthop 1994;18:42-46.
    • (1994) Int Orthop , vol.18 , pp. 42-46
    • Kim, N.H.1    Hahn, S.B.2    Park, H.W.3    Yang, I.H.4
  • 24
    • 0030333163 scopus 로고    scopus 로고
    • Comparative biomechanical evaluation of different external fixation sidebars: Stainless-steel tubes versus carbon fiber rods
    • Kowalski M, Schemitsh EH, Harrington RM, Chapman JR, Swiontkowski MF. Comparative biomechanical evaluation of different external fixation sidebars: stainless-steel tubes versus carbon fiber rods. J Orthop Trauma 1996;10:470-475.
    • (1996) J Orthop Trauma , vol.10 , pp. 470-475
    • Kowalski, M.1    Schemitsh, E.H.2    Harrington, R.M.3    Chapman, J.R.4    Swiontkowski, M.F.5
  • 25
    • 0026669597 scopus 로고
    • Biomechanics of the Ilizarov external fixator
    • Kummer FJ. Biomechanics of the Ilizarov external fixator. Clin Orthop 1992;280:11-14.
    • (1992) Clin Orthop , vol.280 , pp. 11-14
    • Kummer, F.J.1
  • 26
    • 0029936531 scopus 로고    scopus 로고
    • A review of 240 patients undergoing distraction osteogenesis for congenital post-traumatic or postinfective limb length discrepancy
    • Maffulli N, Lombardi C, Matarazzo L, Nele U, Pagnotta G, Fixsen JA. A review of 240 patients undergoing distraction osteogenesis for congenital post-traumatic or postinfective limb length discrepancy. J Am Coll Surg 1996;182:394-402.
    • (1996) J Am Coll Surg , vol.182 , pp. 394-402
    • Maffulli, N.1    Lombardi, C.2    Matarazzo, L.3    Nele, U.4    Pagnotta, G.5    Fixsen, J.A.6
  • 27
    • 0026483971 scopus 로고
    • Internal versus external fixation of bicondylar tibial plateau fractures
    • Mallik AR, Covall DJ, Whitelaw GP. Internal versus external fixation of bicondylar tibial plateau fractures. Orthop Rev 1992;21(12):1433-1436.
    • (1992) Orthop Rev , vol.21 , Issue.12 , pp. 1433-1436
    • Mallik, A.R.1    Covall, D.J.2    Whitelaw, G.P.3
  • 28
    • 0029017383 scopus 로고
    • External fixation and limited internal fixation for complex fractures of the tibial plateau
    • Marsh JL, Smith ST, Do TT. External fixation and limited internal fixation for complex fractures of the tibial plateau. J Bone Joint Surg 1995;77A:661-673.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 661-673
    • Marsh, J.L.1    Smith, S.T.2    Do, T.T.3
  • 29
    • 0021091538 scopus 로고
    • Comparison of mechanical performance of four types of external fixators
    • McCoy MT, Chao EYS, Kassman RA. Comparison of mechanical performance of four types of external fixators. Clin Orthop 1983;180:23-33.
    • (1983) Clin Orthop , vol.180 , pp. 23-33
    • McCoy, M.T.1    Chao, E.Y.S.2    Kassman, R.A.3
  • 30
    • 0027213208 scopus 로고
    • Treatment of large bone defects with the Ilizarov technique
    • Nagger L, Chevalley F, Blanc CH, Livio J. Treatment of large bone defects with the Ilizarov technique. J Trauma 1993;34:390-393.
    • (1993) J Trauma , vol.34 , pp. 390-393
    • Nagger, L.1    Chevalley, F.2    Blanc, C.H.3    Livio, J.4
  • 31
    • 0028130484 scopus 로고
    • Biomechanics of radiotransparent external fixators
    • Nele U, Maffulli N, Pintore E. Biomechanics of radiotransparent external fixators. Clin Orthop 1994;308:68-72.
    • (1994) Clin Orthop , vol.308 , pp. 68-72
    • Nele, U.1    Maffulli, N.2    Pintore, E.3
  • 33
    • 0026719736 scopus 로고
    • The effect of wire configuration on the stability of the Ilizarov external fixator
    • Orbay GL, Frankel VH, Kummer FJ. The effect of wire configuration on the stability of the Ilizarov external fixator. Clin Orthop 1989; 279:299-303.
    • (1989) Clin Orthop , vol.279 , pp. 299-303
    • Orbay, G.L.1    Frankel, V.H.2    Kummer, F.J.3
  • 34
    • 0027176732 scopus 로고
    • Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators
    • Podolsky A, Chao EYS. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators. Clin Orthop 1993;293:61-70.
    • (1993) Clin Orthop , vol.293 , pp. 61-70
    • Podolsky, A.1    Chao, E.Y.S.2
  • 35
    • 0029617399 scopus 로고
    • Combination of the Ilizarov ring fixator with the unilateral AO tube fixator: Initial clinical experience with the hybrid system
    • Raschke MJ, Hoffman R, Khodododyan C, von Fournier C, Sudcamp NP, Has NP. Combination of the Ilizarov ring fixator with the unilateral AO tube fixator: initial clinical experience with the hybrid system. Unfallchirurg 1995;98:627-632.
    • (1995) Unfallchirurg , vol.98 , pp. 627-632
    • Raschke, M.J.1    Hoffman, R.2    Khodododyan, C.3    Von Fournier, C.4    Sudcamp, N.P.5    Has, N.P.6
  • 36
    • 0023761149 scopus 로고
    • "Ring fixator" for treatment of lower leg fractures. a review of 30 cases treated by a new external fixation system
    • Reith HB, Boddeker W, Pelzer C. Kozuschek W. "Ring fixator" for treatment of lower leg fractures. A review of 30 cases treated by a new external fixation system. Int Surg 1988;73:170-172.
    • (1988) Int Surg , vol.73 , pp. 170-172
    • Reith, H.B.1    Boddeker, W.2    Pelzer, C.3    Kozuschek, W.4
  • 37
    • 0029859197 scopus 로고    scopus 로고
    • Differentiation of bone-tissue remodeling response to axial and torsional loading in the turkey ulna
    • Rubin C, Gross T, Qin Y, Fritton S, Guilak F, McLeod K. Differentiation of bone-tissue remodeling response to axial and torsional loading in the turkey ulna. J Bone Joint Surg 1996;78-A:1523-1533.
    • (1996) J Bone Joint Surg , vol.78 A , pp. 1523-1533
    • Rubin, C.1    Gross, T.2    Qin, Y.3    Fritton, S.4    Guilak, F.5    McLeod, K.6
  • 39
    • 0019493298 scopus 로고
    • Measurement of fracture gap motion in external fixation
    • Seligson DS, Powers G, O'Connell P, Pope MH. Measurement of fracture gap motion in external fixation. J Trauma 1981;21:798-801.
    • (1981) J Trauma , vol.21 , pp. 798-801
    • Seligson, D.S.1    Powers, G.2    O'Connell, P.3    Pope, M.H.4
  • 40
    • 0028792125 scopus 로고
    • External fixation for tibial fractures: Clinical results and cost effectiveness
    • Shaw DL, Lawton JO. External fixation for tibial fractures: clinical results and cost effectiveness. J R Coll Surg Edinb 1995;40:344-346.
    • (1995) J R Coll Surg Edinb , vol.40 , pp. 344-346
    • Shaw, D.L.1    Lawton, J.O.2
  • 41
    • 0028726604 scopus 로고    scopus 로고
    • Bicondylar tibial plateau fratures treated with a hybrid ring external fixator: A preliminary study
    • 994
    • Stamer DT, Schenk R, Staggers B, Aurori K, Aurori B, Behrens F. Bicondylar tibial plateau fratures treated with a hybrid ring external fixator: a preliminary study. J Orthop Trauma 994:8:455-461.
    • J Orthop Trauma , vol.8 , pp. 455-461
    • Stamer, D.T.1    Schenk, R.2    Staggers, B.3    Aurori, K.4    Aurori, B.5    Behrens, F.6
  • 43
    • 0028033031 scopus 로고
    • High-energy fractures of the tibial plateau
    • Watson JT. High-energy fractures of the tibial plateau. Orthop Clin North Am 1994;25:723-751.
    • (1994) Orthop Clin North Am , vol.25 , pp. 723-751
    • Watson, J.T.1
  • 44
    • 0029315767 scopus 로고    scopus 로고
    • The use of combnation internal fixation and hybrid external fixation in severe proximal tibia fractures
    • 995
    • Weiner LS, Kelly M, Yang E, Steuer J, Watnik N, Evans E, Bergman M. The use of combnation internal fixation and hybrid external fixation in severe proximal tibia fractures. J Orthop Trauma 995;9:244-250.
    • J Orthop Trauma , vol.9 , pp. 244-250
    • Weiner, L.S.1    Kelly, M.2    Yang, E.3    Steuer, J.4    Watnik, N.5    Evans, E.6    Bergman, M.7
  • 45
    • 0023218447 scopus 로고
    • The early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation
    • Williams EA, Rand JA, An KN, Chao EYS, Kelly PJ. The early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation. J Bone Joint Surg 1987;69A:355-364.
    • (1987) J Bone Joint Surg , vol.69 A , pp. 355-364
    • Williams, E.A.1    Rand, J.A.2    An, K.N.3    Chao, E.Y.S.4    Kelly, P.J.5
  • 46
    • 0021690879 scopus 로고
    • Comparison of oseotomy healing under external fixation devices with different stiffness characteristics
    • Wu J, Shyr HS, Chao EYS, Kelly PJ. Comparison of oseotomy healing under external fixation devices with different stiffness characteristics. J Bone Joint Surg 1984;66A:1258-1264.
    • (1984) J Bone Joint Surg , vol.66 A , pp. 1258-1264
    • Wu, J.1    Shyr, H.S.2    Chao, E.Y.S.3    Kelly, P.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.