메뉴 건너뛰기




Volumn 29, Issue 1, 1998, Pages 52-65

All-ceramic crowns on modified CeraOne abutments: A case report

Author keywords

All ceramic crown; Br nemark implant; Celay In Ceram; CeraOne abutment; Customizing; Single tooth implant

Indexed keywords

ALUMINUM OXIDE; IN CERAM; IN-CERAM;

EID: 0031604449     PISSN: 00336572     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (14)
  • 2
    • 0027588723 scopus 로고
    • Considerations for successful single tooth implant restorations
    • Sullivan DY, Sherwood RL. Considerations for successful single tooth implant restorations. J Esthet Dent 1993;5:118-124.
    • (1993) J Esthet Dent , vol.5 , pp. 118-124
    • Sullivan, D.Y.1    Sherwood, R.L.2
  • 3
    • 0028491056 scopus 로고
    • Candidates and requirements for single-tooth implant prostheses
    • Balshi TJ. Candidates and requirements for single-tooth implant prostheses. Int J Periodont Rest Dent 1994;14:316-331.
    • (1994) Int J Periodont Rest Dent , vol.14 , pp. 316-331
    • Balshi, T.J.1
  • 4
    • 0027634189 scopus 로고
    • The implant-supported single-tooth restoration. Preoperative evaluation and clinical procedure
    • Boudrias P. The implant-supported single-tooth restoration. Preoperative evaluation and clinical procedure. Dent Clin North Am 1993;37:497-511.
    • (1993) Dent Clin North Am , vol.37 , pp. 497-511
    • Boudrias, P.1
  • 5
    • 0026948617 scopus 로고
    • The anterior single-tooth implant restoration
    • Stauts B. The anterior single-tooth implant restoration. J Calif Dent Assoc 1992;20:35-40.
    • (1992) J Calif Dent Assoc , vol.20 , pp. 35-40
    • Stauts, B.1
  • 7
    • 0030098642 scopus 로고    scopus 로고
    • Copy-milled all-ceramic Celay-InCeram crowns for modified CeraOne abutments. A technical report
    • Pröbster L, Girthofer S, Groten M, Rein B. Copy-milled all-ceramic Celay-InCeram crowns for modified CeraOne abutments. A technical report. Int J Oral Maxillofac Implants 1996;11: 201-204.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 201-204
    • Pröbster, L.1    Girthofer, S.2    Groten, M.3    Rein, B.4
  • 10
    • 0028391517 scopus 로고
    • Copy milling ceramic inlays from resin analogs: A practicable approach with the CELAY system
    • Eidenbenz S, Lehner CR, Schärer P. Copy milling ceramic inlays from resin analogs: A practicable approach with the CELAY system. Int J Prosthodont 1994;7:134-142.
    • (1994) Int J Prosthodont , vol.7 , pp. 134-142
    • Eidenbenz, S.1    Lehner, C.R.2    Schärer, P.3
  • 11
    • 0344778966 scopus 로고
    • Kopiergefräste, glas-infiltrierte Aluminiumoxidkeramikkronen - Das Celay In-Ceram System
    • Pröbster L, Groten M, Girthofer S. Kopiergefräste, glas-infiltrierte Aluminiumoxidkeramikkronen - das Celay In-Ceram System. Phillip J 1994;11:577-584.
    • (1994) Phillip J , vol.11 , pp. 577-584
    • Pröbster, L.1    Groten, M.2    Girthofer, S.3
  • 12
    • 0029339631 scopus 로고
    • Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns
    • Rinke S, Hüls A, Jahn L. Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns. Int J Prosthodont 1995;8:303-310.
    • (1995) Int J Prosthodont , vol.8 , pp. 303-310
    • Rinke, S.1    Hüls, A.2    Jahn, L.3
  • 13
    • 24744437096 scopus 로고    scopus 로고
    • European patent EP 8640007810, 1986
    • Sadoun M. European patent EP 8640007810, 1986.
    • Sadoun, M.1
  • 14
    • 0030095844 scopus 로고    scopus 로고
    • Four-year clinical study of glass-infiltrated, sintered alumina crowns
    • Pröbster L. Four-year clinical study of glass-infiltrated, sintered alumina crowns. J Oral Rehabil 1996;23:147-151.
    • (1996) J Oral Rehabil , vol.23 , pp. 147-151
    • Pröbster, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.