메뉴 건너뛰기




Volumn 85, Issue 1, 1998, Pages 33-36

Selective interference with pacemaker activity by electrical dental devices

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ARTIFICIAL HEART PACEMAKER; DENTAL CARE; DENTAL EQUIPMENT; ELECTRICITY; ELECTROMAGNETIC FIELD; EQUIPMENT; HEART ARRHYTHMIA; HUMAN; INSTRUMENTATION; PREVENTIVE DENTISTRY; ULTRASOUND;

EID: 0031601225     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1079-2104(98)90394-8     Document Type: Article
Times cited : (69)

References (22)
  • 1
    • 33747372942 scopus 로고
    • Pacing
    • Giuliani ER, Gersh B J, McGoon MD, Hayes DL, Schaff HV, editors. St. Louis: Mosby
    • Imich W, Parsonnet V, Myers GH. Pacing. In: Giuliani ER, Gersh B J, McGoon MD, Hayes DL, Schaff HV, editors. Mayo Clinic practice of cardiology. 3rd ed. St. Louis: Mosby; 1995. p. 909-10.
    • (1995) Mayo Clinic Practice of Cardiology. 3rd Ed. , pp. 909-910
    • Imich, W.1    Parsonnet, V.2    Myers, G.H.3
  • 4
    • 0015957965 scopus 로고
    • The pacemaker patient and the electromagnetic environment
    • Smyth NPD, Parsonnet V, Escher DJW, Furman S. The pacemaker patient and the electromagnetic environment. JAMA 1974;227:1412.
    • (1974) JAMA , vol.227 , pp. 1412
    • Smyth, N.P.D.1    Parsonnet, V.2    Escher, D.J.W.3    Furman, S.4
  • 5
    • 0016982234 scopus 로고
    • Pacemaker triggering (inhibition) by electric toothbrush
    • Escher DJW, Parker B, Furman S. Pacemaker triggering (inhibition) by electric toothbrush. Am J Cardiol 1976;38:126-7.
    • (1976) Am J Cardiol , vol.38 , pp. 126-127
    • Escher, D.J.W.1    Parker, B.2    Furman, S.3
  • 7
    • 0015579601 scopus 로고
    • Possible electromagnetic interference with cardiac pacemakers from dental induction casting machines and electrosurgical devices
    • Council on Dental Materials and Devices. Possible electromagnetic interference with cardiac pacemakers from dental induction casting machines and electrosurgical devices. JADA 1973;86:426.
    • (1973) JADA , vol.86 , pp. 426
  • 8
    • 0016126784 scopus 로고
    • A preliminary evaluation of the effects of electrical pulp testers on dogs with artificial pacemakers
    • Woolley LH, Woodworth J, Dobbs JL. A preliminary evaluation of the effects of electrical pulp testers on dogs with artificial pacemakers. JADA 1974;89:1099-101.
    • (1974) JADA , vol.89 , pp. 1099-1101
    • Woolley, L.H.1    Woodworth, J.2    Dobbs, J.L.3
  • 9
    • 0016620633 scopus 로고
    • The individual with a pacemaker in the dental environment
    • Simon AB, Linde B, Bonnette GH, Schlentz RJ. The individual with a pacemaker in the dental environment JADA 1975;91: 1224-9.
    • (1975) JADA , vol.91 , pp. 1224-1229
    • Simon, A.B.1    Linde, B.2    Bonnette, G.H.3    Schlentz, R.J.4
  • 10
    • 0017666979 scopus 로고
    • Dental treatment of patient with a cardiac pacemaker
    • Rezai FR. Dental treatment of patient with a cardiac pacemaker. Oral Surg 1977;44:662-5.
    • (1977) Oral Surg , vol.44 , pp. 662-665
    • Rezai, F.R.1
  • 11
    • 0018213354 scopus 로고
    • The management of the pacemaker wearer during dental hygiene treatment
    • Griffiths PV. The management of the pacemaker wearer during dental hygiene treatment. Dent Hyg 1978;52:573-6.
    • (1978) Dent Hyg , vol.52 , pp. 573-576
    • Griffiths, P.V.1
  • 13
    • 11544374947 scopus 로고
    • Behavior of stimulation resistance and stimulation threshold of pacemaker leads during and after implantation
    • Nederlandse Werkgroep Hartstimulatie, October
    • Sedney MI, Rodrigo FA, Buis B, Koops J. Behavior of stimulation resistance and stimulation threshold of pacemaker leads during and after implantation. In: Cursus Pacemakers, Nederlandse Werkgroep Hartstimulatie, October 1982:10-20.
    • (1982) Cursus Pacemakers , pp. 10-20
    • Sedney, M.I.1    Rodrigo, F.A.2    Buis, B.3    Koops, J.4
  • 14
    • 11544328329 scopus 로고
    • Artificial cardiac pacemakers
    • Hurst JW,editor. New York: McGraw-Hill
    • Mond HG, Sloman JG. Artificial cardiac pacemakers. In: Hurst JW,editor. The heart, arteries, and veins. 7th ed. New York: McGraw-Hill; 1990. p. 561-80.
    • (1990) The Heart, Arteries, and Veins. 7th Ed. , pp. 561-580
    • Mond, H.G.1    Sloman, J.G.2
  • 15
    • 0024239649 scopus 로고
    • The effect of 50 Hz external electrical interference on implanted cardiac pacemakers
    • Kaye GC, Butrous GS, Allen A, Meldrum SJ, Male JC, Carom AJ. The effect of 50 Hz external electrical interference on implanted cardiac pacemakers. Pace 1988;11:999-1008.
    • (1988) Pace , vol.11 , pp. 999-1008
    • Kaye, G.C.1    Butrous, G.S.2    Allen, A.3    Meldrum, S.J.4    Male, J.C.5    Carom, A.J.6
  • 16
    • 0027410962 scopus 로고
    • Electronic article surveillance: A possible danger for pacemaker patients
    • Dodinot B, Godenir J-P, Costa AB. Electronic article surveillance: a possible danger for pacemaker patients. Pace 1993;16: 46-53.
    • (1993) Pace , vol.16 , pp. 46-53
    • Dodinot, B.1    Godenir, J.-P.2    Costa, A.B.3
  • 17
    • 0020440203 scopus 로고
    • The pacemaker patient in the dental surgery
    • Luker J. The pacemaker patient in the dental surgery. J Dent 1982;10:326-32.
    • (1982) J Dent , vol.10 , pp. 326-332
    • Luker, J.1
  • 18
    • 0024641983 scopus 로고
    • Störanfälligkeit frequenzadaptiver herzchrittmacher bei zahnärztlichen behandlungsmaßnahmen
    • Rahn R, Zegelman M, Brief I, Kreuzer J, Frenkel G. Störanfälligkeit frequenzadaptiver herzchrittmacher bei zahnärztlichen behandlungsmaßnahmen. Dtsch Zahnarztl Z 1989; 44:244-7.
    • (1989) Dtsch Zahnarztl Z , vol.44 , pp. 244-247
    • Rahn, R.1    Zegelman, M.2    Brief, I.3    Kreuzer, J.4    Frenkel, G.5
  • 19
    • 11544310770 scopus 로고
    • Dental treatment of patients with cardiac pacemaker implants
    • Walter C. Dental treatment of patients with cardiac pacemaker implants. Quint Int 1975;8:57.
    • (1975) Quint Int , vol.8 , pp. 57
    • Walter, C.1
  • 20
    • 17044448516 scopus 로고
    • Electrosurgical equipment and pacemakers: A possible hazard
    • McCormack J. Electrosurgical equipment and pacemakers: a possible hazard. Br Dent J 1975;6:221.
    • (1975) Br Dent J , vol.6 , pp. 221
    • McCormack, J.1
  • 21
    • 0014848547 scopus 로고
    • Electrical interference in noncompetitive pacemakers
    • Sowton E, Gray K, Preston T. Electrical interference in noncompetitive pacemakers. Br Heart J 1970;32:626-32.
    • (1970) Br Heart J , vol.32 , pp. 626-632
    • Sowton, E.1    Gray, K.2    Preston, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.