메뉴 건너뛰기




Volumn 19, Issue 5, 1998, Pages 213-219

Doppler sonographic examination of the time average motion and the flow volume in the transjugular intrahepatio portosystemic shunt (TIPS);Dopplersonographische bestimmung der mittleren flussgeschwindigkelt und des flussvolumens im transjugularen intrahepatischen portosystemischen shunt (TIPS)

Author keywords

Ascites; Duplex sonography; Time average motion (TAM); Transjugular intrahepatic portosystemic shunt (TIPS)

Indexed keywords

ADULT; AGED; ALCOHOL LIVER CIRRHOSIS; ARTICLE; ASCITES; BILE DUCT DISEASE; CLINICAL ARTICLE; CONTROLLED STUDY; DOPPLER FLOWMETRY; FEMALE; FOLLOW UP; HEMODYNAMICS; HEPATITIS C; HUMAN; MALE; MOTION; PORTAL HYPERTENSION; PORTOSYSTEMIC ANASTOMOSIS; STENOSIS; TIME; BLOOD FLOW VELOCITY; BLOOD VOLUME; COLOR ULTRASOUND FLOWMETRY; ECHOGRAPHY; INSTRUMENTATION; MIDDLE AGED; PHYSIOLOGY; PORTAL VEIN; POSTOPERATIVE COMPLICATION; TRANSDUCER;

EID: 0031593462     PISSN: 01724614     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2007-1000493     Document Type: Article
Times cited : (2)

References (23)
  • 2
    • 0028222468 scopus 로고
    • Variceal Hemorrhage. Efficacy of transjugular intrahepatic portosystemic shunts created with Strecker Stents
    • Echenagusia AJ, Camunez F, Simo G, Peiro J, Garay MG, Laiz R, Banares R. Variceal Hemorrhage. Efficacy of transjugular intrahepatic portosystemic shunts created with Strecker Stents. Radiology 1994; 192: 235-40.
    • (1994) Radiology , vol.192 , pp. 235-240
    • Echenagusia, A.J.1    Camunez, F.2    Simo, G.3    Peiro, J.4    Garay, M.G.5    Laiz, R.6    Banares, R.7
  • 4
    • 0028182686 scopus 로고
    • TIPSS: Indikationen und postoperatives Management
    • Theilman L, Sauer P. TIPSS: Indikationen und postoperatives Management. Radiologe 1994; 34: 164-7.
    • (1994) Radiologe , vol.34 , pp. 164-167
    • Theilman, L.1    Sauer, P.2
  • 5
    • 0028270179 scopus 로고
    • Transjugular intrahepatic portosystemic shunt: Angiographic follow-up and secondary interventions
    • Hausegger, KA, Sternthal HM, Klein GE, Karaic R, Stauber R, Zenker G. Transjugular intrahepatic portosystemic shunt: Angiographic follow-up and secondary interventions. Radiology 1994; 191: 177-81.
    • (1994) Radiology , vol.191 , pp. 177-181
    • Hausegger, K.A.1    Sternthal, H.M.2    Klein, G.E.3    Karaic, R.4    Stauber, R.5    Zenker, G.6
  • 7
    • 0031012707 scopus 로고    scopus 로고
    • Stenosis of transjugular portosystemic shunts: Presentation and management
    • Sterling KM, Darcy MD. Stenosis of transjugular portosystemic shunts: presentation and management. AJR 1997; 168: 239-44.
    • (1997) AJR , vol.168 , pp. 239-244
    • Sterling, K.M.1    Darcy, M.D.2
  • 9
    • 7844251693 scopus 로고    scopus 로고
    • Transjugulärer intrahepatischer portosystemischer Shunt: Evaluation mittels farbkodierter Dopplersonographie
    • Herold C, Becker D, Hahn EG. Transjugulärer intrahepatischer portosystemischer Shunt: Evaluation mittels farbkodierter Dopplersonographie. Ultraschall in Med. 1997; Suppl. 1: 38.
    • (1997) Ultraschall in Med. , Issue.1 SUPPL. , pp. 38
    • Herold, C.1    Becker, D.2    Hahn, E.G.3
  • 10
    • 0027367202 scopus 로고
    • Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity
    • Chong WK, Malisch TA, Mazer MJ, Lind CD. Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity. Radiology 1993; 189: 789-93.
    • (1993) Radiology , vol.189 , pp. 789-793
    • Chong, W.K.1    Malisch, T.A.2    Mazer, M.J.3    Lind, C.D.4
  • 11
    • 0028909884 scopus 로고
    • Detection of transjugular intrahepatic portosystemic shunt dysfunction: Value of duplex doppler sonography
    • Dodd GD, Zajko AB, Orons PD, Martin MS, Eichner LS, Santaguida LA. Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex doppler sonography. AJR 1995; 164: 1119-24.
    • (1995) AJR , vol.164 , pp. 1119-1124
    • Dodd, G.D.1    Zajko, A.B.2    Orons, P.D.3    Martin, M.S.4    Eichner, L.S.5    Santaguida, L.A.6
  • 12
    • 0031019466 scopus 로고    scopus 로고
    • Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction
    • Kanterman RY, Darcy MD, Middleton WD, Sterling KM, Teefey SA, Pilgram TK. Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction. AJR 1997; 168: 467-72.
    • (1997) AJR , vol.168 , pp. 467-472
    • Kanterman, R.Y.1    Darcy, M.D.2    Middleton, W.D.3    Sterling, K.M.4    Teefey, S.A.5    Pilgram, T.K.6
  • 13
    • 0030162796 scopus 로고    scopus 로고
    • The hemodynamics of transjugular intrahepatic portosystemic shunts: Investigations with doppler sonography and development of an in vitro model
    • Daniel BL, Rubin JM, Fowlekes JB, Williams DM, Adler RS. The hemodynamics of transjugular intrahepatic portosystemic shunts: investigations with doppler sonography and development of an in vitro model. Acad Radiol 1996; 3: 455-62.
    • (1996) Acad Radiol , vol.3 , pp. 455-462
    • Daniel, B.L.1    Rubin, J.M.2    Fowlekes, J.B.3    Williams, D.M.4    Adler, R.S.5
  • 15
    • 0029993680 scopus 로고    scopus 로고
    • The transjugular intrahepatic portosystemic stent-shunt. A review of the literature and own experiences
    • Rössle M, Haag K, Blum HE. The transjugular intrahepatic portosystemic stent-shunt. A review of the literature and own experiences. J Gastroenterol Hepatol 1996; 11: 293-98.
    • (1996) J Gastroenterol Hepatol , vol.11 , pp. 293-298
    • Rössle, M.1    Haag, K.2    Blum, H.E.3
  • 16
    • 0029055898 scopus 로고
    • Duplex sonography after transjugular intrahepatic shunts (TIPS): Normal hemodynamic findings and efficacy in predicting shunt patency and stenosis
    • Foshager MC, Ferral H, Nazarian GK, Castaneda-Zuniga WR, Letourneau JG. Duplex sonography after transjugular intrahepatic shunts (TIPS): Normal hemodynamic findings and efficacy in predicting shunt patency and stenosis. AJR 1995; 165: 1-7.
    • (1995) AJR , vol.165 , pp. 1-7
    • Foshager, M.C.1    Ferral, H.2    Nazarian, G.K.3    Castaneda-Zuniga, W.R.4    Letourneau, J.G.5
  • 17
    • 0028956285 scopus 로고
    • Short- and Long-Term Hemodynamic Effects of Transjugular Intrahepatic Portosystemic Shunts: A Doppler/Manometric Correlative Study
    • Lafortune M, Martinet JM, Denys A, Patriquin H, Dauzat M, Dufresne MP, Colombato L, Pomier-Layrargues G. Short- and Long-Term Hemodynamic Effects of Transjugular Intrahepatic Portosystemic Shunts: A Doppler/Manometric Correlative Study. AJR 1995; 164: 997-1002.
    • (1995) AJR , vol.164 , pp. 997-1002
    • Lafortune, M.1    Martinet, J.M.2    Denys, A.3    Patriquin, H.4    Dauzat, M.5    Dufresne, M.P.6    Colombato, L.7    Pomier-Layrargues, G.8
  • 19
    • 0027397626 scopus 로고
    • Morphologic and hemodynamic findings at sonography before and after creation of a transjugular intrahepatic portosystemic shunt
    • Surratt RS, Middleton WD, Darcy MD, Melson GL, Brink JA. Morphologic and hemodynamic findings at sonography before and after creation of a transjugular intrahepatic portosystemic shunt. AJR 1993; 160: 627-30.
    • (1993) AJR , vol.160 , pp. 627-630
    • Surratt, R.S.1    Middleton, W.D.2    Darcy, M.D.3    Melson, G.L.4    Brink, J.A.5
  • 20
    • 7844233854 scopus 로고    scopus 로고
    • Der diagnostische Wert der portalen Duplexsonographie bei Leberzirrhose
    • Körner T. Der diagnostische Wert der portalen Duplexsonographie bei Leberzirrhose. Ultraschall in Med. 1996; 70-84.
    • (1996) Ultraschall in Med. , pp. 70-84
    • Körner, T.1
  • 22
    • 0028955939 scopus 로고
    • The reducing stent: Treatment for transjugular intrahepatic portosystemic shunt-induced refractory hepatic encephalopathy and liver failure
    • Hauenstein, KH, Haag K, Ochs A, Langer M, Rössle M. The reducing stent: treatment for transjugular intrahepatic portosystemic shunt-induced refractory hepatic encephalopathy and liver failure. Radiology 1995; 194: 175-9.
    • (1995) Radiology , vol.194 , pp. 175-179
    • Hauenstein, K.H.1    Haag, K.2    Ochs, A.3    Langer, M.4    Rössle, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.