메뉴 건너뛰기




Volumn 88, Issue 1-4, 1997, Pages 111-119

Air flow and associated sensible heat exchanges in a naturally ventilated greenhouse

Author keywords

Air flow; Computational fluid dynamics; Temperature; Three dimensional

Indexed keywords

AIR FLOW; GREENHOUSE; HEAT TRANSFER; VENTILATION;

EID: 0031592292     PISSN: 01681923     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-1923(97)00043-9     Document Type: Article
Times cited : (86)

References (10)
  • 1
    • 21844443220 scopus 로고
    • Etude expérimentale et modélisation de l'aération naturelle des serres
    • Note interne I.N.R.A. 93-1; Station de Bioclimatologie de Montfavet 84140, France
    • Boulard, T., 1993. Etude expérimentale et modélisation de l'aération naturelle des serres. Récapitulatif des résultats des études conduites de 1988à, 1992. Note interne I.N.R.A. 93-1; Station de Bioclimatologie de Montfavet 84140, France.
    • (1993) Récapitulatif des Résultats des Études Conduites de 1988à, 1992
    • Boulard, T.1
  • 2
    • 0027796972 scopus 로고
    • A simple greenhouse climate control model incorporating effects of aeration and evaporative cooling
    • Boulard, T., Baille, A., 1993. A simple greenhouse climate control model incorporating effects of aeration and evaporative cooling. Agric. For. Meteorol. 65, 145-157.
    • (1993) Agric. For. Meteorol. , vol.65 , pp. 145-157
    • Boulard, T.1    Baille, A.2
  • 3
    • 0030025421 scopus 로고    scopus 로고
    • Characterisation of the mechanisms involved in the natural ventilation of greenhouses
    • Boulard, T., Meneses, J., Mermier, M., Papadakis, G., 1996. Characterisation of the mechanisms involved in the natural ventilation of greenhouses. Agric. For. Meteorol. 79, 61-77.
    • (1996) Agric. For. Meteorol. , vol.79 , pp. 61-77
    • Boulard, T.1    Meneses, J.2    Mermier, M.3    Papadakis, G.4
  • 5
    • 0026440393 scopus 로고
    • Measurement and prediction of greenhouse ventilation rates
    • Fernandez, J.E., Bailey, B.J., 1992. Measurement and prediction of greenhouse ventilation rates. Agric. For. Meteorol. 58, 229-245.
    • (1992) Agric. For. Meteorol. , vol.58 , pp. 229-245
    • Fernandez, J.E.1    Bailey, B.J.2
  • 6
    • 0344218126 scopus 로고    scopus 로고
    • Natural ventilation of a greenhouse with ridge and side openings: Sensitivity to temperature and wind effects
    • in press
    • Kittas, C., Boulard, T., Papadakis, G., Mermier, M., 1996. Natural ventilation of a greenhouse with ridge and side openings: Sensitivity to temperature and wind effects. Transactions of ASAE, in press.
    • (1996) Transactions of ASAE
    • Kittas, C.1    Boulard, T.2    Papadakis, G.3    Mermier, M.4
  • 7
    • 0023823504 scopus 로고
    • Turbulence measurements during mistral winds with a 1-dimensional sonic anemometer
    • McAneney, K.J., Baille, A., Sappe, G., 1988. Turbulence measurements during mistral winds with a 1-dimensional sonic anemometer. Boundary layer Meteorol. 42, 153-166.
    • (1988) Boundary Layer Meteorol. , vol.42 , pp. 153-166
    • McAneney, K.J.1    Baille, A.2    Sappe, G.3
  • 9
    • 0000453799 scopus 로고    scopus 로고
    • Measurements and analysis of air exchange rates in a greenhouse with continuous roof and side opening
    • Papadakis, G., Mermier, M., Meneses, J.F., Boulard, T., 1996. Measurements and analysis of air exchange rates in a greenhouse with continuous roof and side opening. J. Agric. Eng. Res. 63, 219-228.
    • (1996) J. Agric. Eng. Res. , vol.63 , pp. 219-228
    • Papadakis, G.1    Mermier, M.2    Meneses, J.F.3    Boulard, T.4
  • 10
    • 0028079198 scopus 로고
    • Transpirational cooling of a greenhouse crop with partial ground cover
    • Seginer, I., 1994. Transpirational cooling of a greenhouse crop with partial ground cover. Agric. For. Meteorol. 71, 265-281.
    • (1994) Agric. For. Meteorol. , vol.71 , pp. 265-281
    • Seginer, I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.