메뉴 건너뛰기




Volumn 59, Issue 1-2, 1997, Pages 145-153

Fast on-fine flow injection analysis system for IgG monitoring in bioprocesses

Author keywords

Binding assay; Bioprocess monitoring; Flow injection analysis; IgG; Validation

Indexed keywords

IMMUNOGLOBULIN G;

EID: 0031576556     PISSN: 01681656     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-1656(97)00177-6     Document Type: Article
Times cited : (23)

References (13)
  • 1
    • 0026645486 scopus 로고
    • Determination of kinetic constants for the interaction between a monoclonal antibody and peptides using surface plasmon resonance
    • Altschuh D, Dubs M.-C. Determination of kinetic constants for the interaction between a monoclonal antibody and peptides using surface plasmon resonance. Biochemistry. 31:1992;6298-6304.
    • (1992) Biochemistry , vol.31 , pp. 6298-6304
    • Altschuh, D.1    Dubs, M.-C.2
  • 3
    • 0025899125 scopus 로고
    • Antibody quantitation in seconds using affinity perfusion chromatography
    • Fulton S.P., Meys M., Varady L., Jansen R., Afeyan N.B. Antibody quantitation in seconds using affinity perfusion chromatography. Biochromatography. 11:1991;226-231.
    • (1991) Biochromatography , vol.11 , pp. 226-231
    • Fulton, S.P.1    Meys, M.2    Varady, L.3    Jansen, R.4    Afeyan, N.B.5
  • 4
    • 0024373895 scopus 로고
    • Comparison of protein A, protein G, and copolymerized hydroxyapatite for the purification of human monoclonal antibodies
    • Jungbauer A., Tauer C., Reiter M., Purtscher M., Wenisch E., Steindl F., Buchacher A., Katinger H. Comparison of protein A, protein G, and copolymerized hydroxyapatite for the purification of human monoclonal antibodies. J. Chromatogr. 476:1989;257-268.
    • (1989) J. Chromatogr. , vol.476 , pp. 257-268
    • Jungbauer, A.1    Tauer, C.2    Reiter, M.3    Purtscher, M.4    Wenisch, E.5    Steindl, F.6    Buchacher, A.7    Katinger, H.8
  • 5
    • 0344694513 scopus 로고
    • Separation-free enzyme fluorescence immunoassay by continuous flow injection analysis
    • In: Lenhoff, H.M. (Ed.), Plenum Press, New York
    • Kelly, T.A., 1985. Separation-free enzyme fluorescence immunoassay by continuous flow injection analysis. In: Lenhoff, H.M. (Ed.), Enzyme-Mediated Immunoassay. Plenum Press, New York, pp. 191-201.
    • (1985) Enzyme-Mediated Immunoassay , pp. 191-201
    • Kelly, T.A.1
  • 6
    • 0026703444 scopus 로고
    • Real time analysis of antibody-antigen reaction kinetics
    • Malmborg A.-C., Michaelsson A. Real time analysis of antibody-antigen reaction kinetics. Scand. J. Immunol. 35:1992;642-650.
    • (1992) Scand. J. Immunol. , vol.35 , pp. 642-650
    • Malmborg, A.-C.1    Michaelsson, A.2
  • 9
    • 0344694512 scopus 로고
    • Luminescence detection in flow injection analysis
    • Miller J.N. Luminescence detection in flow injection analysis. Anal. Proc. 18:1981;264-267.
    • (1981) Anal. Proc. , vol.18 , pp. 264-267
    • Miller, J.N.1
  • 10
    • 0025768237 scopus 로고
    • Determination of antibodies to human growth hormone in serum by protein G affinity-reverse-phase tandem column chromatographie with fluorescence detection
    • Riggin A., Reginer F.E. Determination of antibodies to human growth hormone in serum by protein G affinity-reverse-phase tandem column chromatographie with fluorescence detection. Anal. Chim. Acta. 249:1991;185-193.
    • (1991) Anal. Chim. Acta , vol.249 , pp. 185-193
    • Riggin, A.1    Reginer, F.E.2
  • 11
    • 0026128330 scopus 로고
    • Quantification of antibodies to human growth hormone by high-performance protein G affinity chromatographie with fluorescence detection
    • Riggin A., Reginer F.E., Sportsman J.R. Quantification of antibodies to human growth hormone by high-performance protein G affinity chromatographie with fluorescence detection. Anal. Chem. 63:1991;468-474.
    • (1991) Anal. Chem. , vol.63 , pp. 468-474
    • Riggin, A.1    Reginer, F.E.2    Sportsman, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.