메뉴 건너뛰기




Volumn 36, Issue 3, 1997, Pages 381-386

Biocompatibility of alumina ceramic and polyethylene as materials for pivot bearings of a centrifugal blood pump

Author keywords

Alumina ceramic; Biocompatibility; Centrifugal blood pump; Pivot bearing; Polyethylene

Indexed keywords

ALUMINA; BIOCOMPATIBILITY; BLOOD; CERAMIC MATERIALS; MUTAGENESIS; TOXICITY; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES;

EID: 0031554910     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(19970905)36:3<381::AID-JBM12>3.0.CO;2-H     Document Type: Article
Times cited : (44)

References (28)
  • 1
    • 0029044314 scopus 로고
    • Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study
    • N. Sugano, T. Nishii, K. Nakata, K. Masuhara, and K. Takaoka, "Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study," J. Bone Joint. Surg. Br., 77, 548-556 (1995).
    • (1995) J. Bone Joint. Surg. Br. , vol.77 , pp. 548-556
    • Sugano, N.1    Nishii, T.2    Nakata, K.3    Masuhara, K.4    Takaoka, K.5
  • 2
    • 0025325529 scopus 로고
    • Ten-year socket wear in 66 hip arthroplasties - Ceramic versus metal heads
    • H. Schuller and R. Marti, "Ten-year socket wear in 66 hip arthroplasties - ceramic versus metal heads," Acta Orthop. Scand., 61, 240-248 (1990).
    • (1990) Acta Orthop. Scand. , vol.61 , pp. 240-248
    • Schuller, H.1    Marti, R.2
  • 3
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
    • J. A. Davidson, "Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear," Clin. Orthop., 294, 361-378 (1993).
    • (1993) Clin. Orthop. , vol.294 , pp. 361-378
    • Davidson, J.A.1
  • 9
    • 0020533372 scopus 로고
    • Revised methods for the salmonella mutagenecity test
    • D. Maron and B. N. Ames, "Revised methods for the salmonella mutagenecity test," Mutat. Res., 113, 173-215 (1983).
    • (1983) Mutat. Res. , vol.113 , pp. 173-215
    • Maron, D.1    Ames, B.N.2
  • 10
    • 0028473676 scopus 로고
    • The development of an implantable, portable, electrically powered left ventricular assist device
    • O. H. Frazier, "The development of an implantable, portable, electrically powered left ventricular assist device," Semin. Thorac. Cardiovasc. Surg., 6, 181-187 (1994).
    • (1994) Semin. Thorac. Cardiovasc. Surg. , vol.6 , pp. 181-187
    • Frazier, O.H.1
  • 11
    • 0027393362 scopus 로고
    • Univentricular and biventricular Thoratec VAD support as a bridge to transplantation
    • D. J. Farrar and J. D. Hill, "Univentricular and biventricular Thoratec VAD support as a bridge to transplantation," Ann. Thorac. Surg., 55, 276-282 (1993).
    • (1993) Ann. Thorac. Surg. , vol.55 , pp. 276-282
    • Farrar, D.J.1    Hill, J.D.2
  • 13
    • 0025952502 scopus 로고
    • Clinical experience with the Novacor ventricular assist system: Bridge to transplantation and the transition to permanent application
    • P.M. McCarthy, P.M. Portner, H. G. Tobler, V. A. Starnes, N. Ramasamy, and P. E. Oyer, "Clinical experience with the Novacor ventricular assist system: bridge to transplantation and the transition to permanent application," J. Thorac. Cardiovasc. Surg., 102, 578-587 (1991).
    • (1991) J. Thorac. Cardiovasc. Surg. , vol.102 , pp. 578-587
    • McCarthy, P.M.1    Portner, P.M.2    Tobler, H.G.3    Starnes, V.A.4    Ramasamy, N.5    Oyer, P.E.6
  • 14
    • 0027441538 scopus 로고
    • Chronic left ventricular support with a vented electric assist device
    • O. H. Frazier, "Chronic left ventricular support with a vented electric assist device," Ann. Thorac. Surg., 55, 273-275 (1993).
    • (1993) Ann. Thorac. Surg. , vol.55 , pp. 273-275
    • Frazier, O.H.1
  • 15
    • 0028469275 scopus 로고
    • Centrifugal mechanical assist for postcardiotomy ventricular failure
    • J. J. Curtis, "Centrifugal mechanical assist for postcardiotomy ventricular failure," Semin. Thorac. Cardiovasc. Surg., 6, 140-146 (1994).
    • (1994) Semin. Thorac. Cardiovasc. Surg. , vol.6 , pp. 140-146
    • Curtis, J.J.1
  • 16
    • 0028469244 scopus 로고
    • Bridging to cardiac transplantation with external ventricular assist devices
    • L. R. McBride, "Bridging to cardiac transplantation with external ventricular assist devices," Semin. Thorac. Cardiovasc. Surg., 6, 169-173 (1994).
    • (1994) Semin. Thorac. Cardiovasc. Surg. , vol.6 , pp. 169-173
    • McBride, L.R.1
  • 17
    • 0026672302 scopus 로고
    • Biocompatibility of surgical-grade dense polycrystalline alumina
    • P. S. Christel, "Biocompatibility of surgical-grade dense polycrystalline alumina," Clin. Orthop., 282, 10-18 (1992).
    • (1992) Clin. Orthop. , vol.282 , pp. 10-18
    • Christel, P.S.1
  • 19
    • 0018348212 scopus 로고
    • Tissue reaction to ceramic implant material
    • J. Harms and E. Mausle, "Tissue reaction to ceramic implant material," J. Biomed. Mater. Res., 13, 67-87 (1979).
    • (1979) J. Biomed. Mater. Res. , vol.13 , pp. 67-87
    • Harms, J.1    Mausle, E.2
  • 20
    • 0023328632 scopus 로고
    • The effect of the injection of powdered materials on mouse peritoneal cell population
    • A. Pizzoferrato, A. Vespucci, G. Ciapetti, S. Stea, and C. Tarabusi, "The effect of the injection of powdered materials on mouse peritoneal cell population," J. Biomed. Mater. Res., 21, 419-428 (1987).
    • (1987) J. Biomed. Mater. Res. , vol.21 , pp. 419-428
    • Pizzoferrato, A.1    Vespucci, A.2    Ciapetti, G.3    Stea, S.4    Tarabusi, C.5
  • 21
    • 0025766010 scopus 로고
    • Relationship between chemotaxis and complement activation by ceramic biomaterials
    • A. Remes and D. F. Williams, "Relationship between chemotaxis and complement activation by ceramic biomaterials," Biomaterials, 12, 661-667 (1991).
    • (1991) Biomaterials , vol.12 , pp. 661-667
    • Remes, A.1    Williams, D.F.2
  • 23
    • 0029759211 scopus 로고    scopus 로고
    • Hemolytic characteristics of pivot bearing Gyro centrifugal pump (C1E3) in various clinical simulated conditions
    • Y. Takami, K. Makinouchi, T. Nakazawa, J. Glueck, R. J. Benkowski, and Y. Nosé, "Hemolytic characteristics of pivot bearing Gyro centrifugal pump (C1E3) in various clinical simulated conditions," Artif. Organs, 20, 1042-1049 (1996).
    • (1996) Artif. Organs , vol.20 , pp. 1042-1049
    • Takami, Y.1    Makinouchi, K.2    Nakazawa, T.3    Glueck, J.4    Benkowski, R.J.5    Nosé, Y.6
  • 25
    • 0029239635 scopus 로고
    • Development of a ceramic conduit valve prosthesis for corrective cardiovascular surgery
    • C. R. Gentle and G. D. Tansley, "Development of a ceramic conduit valve prosthesis for corrective cardiovascular surgery," Biomaterials, 16, 245-249 (1995).
    • (1995) Biomaterials , vol.16 , pp. 245-249
    • Gentle, C.R.1    Tansley, G.D.2
  • 26
    • 0023719883 scopus 로고
    • The effects of bulk versus particular polymethylmethacrylate on bone
    • S. B. Goodman, V. L. Fomasier, and J. Kei, "The effects of bulk versus particular polymethylmethacrylate on bone," Clin. Orthop., 232, 255-262 (1988).
    • (1988) Clin. Orthop. , vol.232 , pp. 255-262
    • Goodman, S.B.1    Fomasier, V.L.2    Kei, J.3
  • 27
    • 0029155605 scopus 로고
    • Polyethylene particles stimulate monocyte chemotactic and activating factor production in synovial mononuclear cells in vivo
    • J. Frøkjaer, B. Deleuran, M. Lind, S. Overgaad, K. Søballe, and C. Bünger, "Polyethylene particles stimulate monocyte chemotactic and activating factor production in synovial mononuclear cells in vivo," Acta Orthop. Scand., 66, 303-307 (1995).
    • (1995) Acta Orthop. Scand. , vol.66 , pp. 303-307
    • Frøkjaer, J.1    Deleuran, B.2    Lind, M.3    Overgaad, S.4    Søballe, K.5    Bünger, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.