메뉴 건너뛰기




Volumn 18, Issue 10, 1997, Pages 1929-1934

Changes in blood flow velocity and diameter of the middle cerebral artery during hyperventilation: Assessment with MR and Transcranial Doppler sonography

Author keywords

Arteries, cerebral, middle; Cerebral blood flow; Magnetic resonance, flow studies; Ultrasound, Doppler

Indexed keywords

ADULT; ARTERY DIAMETER; BLOOD FLOW VELOCITY; BRAIN BLOOD FLOW; CONFERENCE PAPER; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; HUMAN; HUMAN EXPERIMENT; HYPERVENTILATION; MAGNETIC RESONANCE ANGIOGRAPHY; MIDDLE CEREBRAL ARTERY; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING;

EID: 0031545998     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (188)

References (21)
  • 1
    • 0020394689 scopus 로고
    • Non-invasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
    • Aaslid R, Markwalder TM, Nornes H. Non-invasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg 1982;57:769-774
    • (1982) J Neurosurg , vol.57 , pp. 769-774
    • Aaslid, R.1    Markwalder, T.M.2    Nornes, H.3
  • 2
    • 0022449467 scopus 로고
    • Transcranial Doppler measurement of the middle cerebral artery blood flow velocity: A validation study
    • Bishop CCR, Powell S, Rutt D, Browse NL. Transcranial Doppler measurement of the middle cerebral artery blood flow velocity: a validation study. Stroke 1986;17:913-915
    • (1986) Stroke , vol.17 , pp. 913-915
    • Bishop, C.C.R.1    Powell, S.2    Rutt, D.3    Browse, N.L.4
  • 3
    • 0023572004 scopus 로고
    • Variations in middle cerebral artery blood flow investigated with noninvasive transcranial blood velocity measurements
    • Lindegaard KF, Lundar T, Wiberg J, Sjoberg D, Aaslid R, Nornes H. Variations in middle cerebral artery blood flow investigated with noninvasive transcranial blood velocity measurements. Stroke 1987;18:1025-1030
    • (1987) Stroke , vol.18 , pp. 1025-1030
    • Lindegaard, K.F.1    Lundar, T.2    Wiberg, J.3    Sjoberg, D.4    Aaslid, R.5    Nornes, H.6
  • 4
    • 0028343750 scopus 로고
    • Comparison of flow and velocity during dynamic autoregulation testing in humans
    • Newell DW, Aaslid R, Lam A, Mayberg TS, Winn HR. Comparison of flow and velocity during dynamic autoregulation testing in humans. Stroke 1994;25:793-797
    • (1994) Stroke , vol.25 , pp. 793-797
    • Newell, D.W.1    Aaslid, R.2    Lam, A.3    Mayberg, T.S.4    Winn, H.R.5
  • 5
    • 0014040424 scopus 로고
    • Effect of contrast material, hypercapnia, hyperventilation, hypertonic glucose and papaverine on the diameter of the cerebral arteries: Angiographic determination in man
    • Huber P, Handa J. Effect of contrast material, hypercapnia, hyperventilation, hypertonic glucose and papaverine on the diameter of the cerebral arteries: angiographic determination in man. Invest Radiol 1976;2:17-32
    • (1976) Invest Radiol , vol.2 , pp. 17-32
    • Huber, P.1    Handa, J.2
  • 6
    • 0024546198 scopus 로고
    • Validity of cerebral arterial blood flow calculations from velocity measurements
    • Kontos HE. Validity of cerebral arterial blood flow calculations from velocity measurements. Stroke 1989;20:1-3
    • (1989) Stroke , vol.20 , pp. 1-3
    • Kontos, H.E.1
  • 7
    • 0027262320 scopus 로고
    • Cerebral arterial diameter during changes in blood pressure and carbon dioxide during craniotomy
    • Giller CA, Bowman G, Dyer H, Mootz L, Krippner W. Cerebral arterial diameter during changes in blood pressure and carbon dioxide during craniotomy. Neurosurgery 1993;32:737-742
    • (1993) Neurosurgery , vol.32 , pp. 737-742
    • Giller, C.A.1    Bowman, G.2    Dyer, H.3    Mootz, L.4    Krippner, W.5
  • 8
    • 0028145341 scopus 로고
    • Quantification of carotid blood flow velocity using MR phase mapping
    • Fürst G, Sitzer M, Hofer M, Steinmetz H, et al. Quantification of carotid blood flow velocity using MR phase mapping. J Comput Assist Tomogr 1994;18:688-696
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 688-696
    • Fürst, G.1    Sitzer, M.2    Hofer, M.3    Steinmetz, H.4
  • 9
    • 0021637357 scopus 로고
    • Dependency of blood flow velocity in the middle cerebral artery on end-tidal carbon dioxide partial pressure: A transcranial ultrasound Doppler study
    • Markwalder TM, Grolimund P, Seiler RW, Roth F, Aaslid R. Dependency of blood flow velocity in the middle cerebral artery on end-tidal carbon dioxide partial pressure: a transcranial ultrasound Doppler study. J Cereb Blood Flow Metab 1984;4:368-372
    • (1984) J Cereb Blood Flow Metab , vol.4 , pp. 368-372
    • Markwalder, T.M.1    Grolimund, P.2    Seiler, R.W.3    Roth, F.4    Aaslid, R.5
  • 10
    • 0025776907 scopus 로고
    • Assessment of cerebral autoregulation dynamics from simultaneous arterial and venous transcranial Doppler recordings in humans
    • Aaslid R, Newell DW, Stooss R, Sorteberg W, Lindegaard KF. Assessment of cerebral autoregulation dynamics from simultaneous arterial and venous transcranial Doppler recordings in humans. Stroke 1991;22:1148-1154
    • (1991) Stroke , vol.22 , pp. 1148-1154
    • Aaslid, R.1    Newell, D.W.2    Stooss, R.3    Sorteberg, W.4    Lindegaard, K.F.5
  • 11
    • 0025821737 scopus 로고
    • Description of a closed window technique for in vivo study of the feline basilar artery
    • Bouma QJ, Levasseur JE, Muizelaar P, Wiatt RG, Kontos HA. Description of a closed window technique for in vivo study of the feline basilar artery. Stroke 1991;22:522-526
    • (1991) Stroke , vol.22 , pp. 522-526
    • Bouma, Q.J.1    Levasseur, J.E.2    Muizelaar, P.3    Wiatt, R.G.4    Kontos, H.A.5
  • 12
    • 0022617393 scopus 로고    scopus 로고
    • Transcranial Doppler sonography: Examination technique and normal reference values
    • Arnold BJ, von Reutern GM. Transcranial Doppler sonography: examination technique and normal reference values. Ultrasound Med Biol 1996;12:115-123
    • (1996) Ultrasound Med Biol , vol.12 , pp. 115-123
    • Arnold, B.J.1    Von Reutern, G.M.2
  • 13
    • 0023235985 scopus 로고
    • Transcranial Doppler ultrasound for the assessment of intracranial arterial flow velocity, 1
    • Hennerici M, Rautenberg W, Sitzer G, Schwartz A. Transcranial Doppler ultrasound for the assessment of intracranial arterial flow velocity, 1. Surg Neurol 1987;27:439-448
    • (1987) Surg Neurol , vol.27 , pp. 439-448
    • Hennerici, M.1    Rautenberg, W.2    Sitzer, G.3    Schwartz, A.4
  • 15
    • 0022641927 scopus 로고
    • Transcranial measurement of blood velocities in the basal cerebral arteries using pulsed Doppler ultrasound velocity as an index of flow
    • Kirkham FJ, Padayachee TS, Parsons S, Seargeant LS, House FR, Gosling RG. Transcranial measurement of blood velocities in the basal cerebral arteries using pulsed Doppler ultrasound velocity as an index of flow. Ultrasound Med Biol 1986;12:15-21
    • (1986) Ultrasound Med Biol , vol.12 , pp. 15-21
    • Kirkham, F.J.1    Padayachee, T.S.2    Parsons, S.3    Seargeant, L.S.4    House, F.R.5    Gosling, R.G.6
  • 16
    • 0024504237 scopus 로고
    • Transcranial pulsed Doppler measurements of blood flow velocity in the middle artery: Reference values at rest and during hyperventilation in healthy volunteers in relation to age and sex
    • Vriens EM, Kraaier V, Musbach M, Wieneke GH, van Huffelen AC. Transcranial pulsed Doppler measurements of blood flow velocity in the middle artery: reference values at rest and during hyperventilation in healthy volunteers in relation to age and sex. Ultrasound Med Biol 1989;15:1-8
    • (1989) Ultrasound Med Biol , vol.15 , pp. 1-8
    • Vriens, E.M.1    Kraaier, V.2    Musbach, M.3    Wieneke, G.H.4    Van Huffelen, A.C.5
  • 18
    • 0024411988 scopus 로고
    • Blood flow in the carotid arteries: Quantification by using phase-sensitive MR imaging
    • Bendel P, Buonocore E, Bockisch A, Besozzi MC. Blood flow in the carotid arteries: quantification by using phase-sensitive MR imaging. AJR Am J Roentgenol 1989;152:1307-1310
    • (1989) AJR Am J Roentgenol , vol.152 , pp. 1307-1310
    • Bendel, P.1    Buonocore, E.2    Bockisch, A.3    Besozzi, M.C.4
  • 19
    • 0025342599 scopus 로고
    • Flow quantification in the superior sagittal sinus using magnetic resonance
    • Mattle H, Edelman RR, Reis MA, Atkinson DJ. Flow quantification in the superior sagittal sinus using magnetic resonance. Neurology 1990;40:813-815
    • (1990) Neurology , vol.40 , pp. 813-815
    • Mattle, H.1    Edelman, R.R.2    Reis, M.A.3    Atkinson, D.J.4
  • 21
    • 0029798380 scopus 로고    scopus 로고
    • Reduced caliber of the internal carotid artery: A normal finding with ipsilateral absence or hypoplasia of the Al segment
    • Kane AG, William PD, Barkovich AJ, Norman D, Dowd CF, Kane TT. Reduced caliber of the internal carotid artery: a normal finding with ipsilateral absence or hypoplasia of the Al segment. AJNR Am J Neuroradiol 1996;17:1295-1301
    • (1996) AJNR Am J Neuroradiol , vol.17 , pp. 1295-1301
    • Kane, A.G.1    William, P.D.2    Barkovich, A.J.3    Norman, D.4    Dowd, C.F.5    Kane, T.T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.