메뉴 건너뛰기




Volumn 12, Issue 3, 1997, Pages 273-280

Comparison of collared and collarless femoral components in primary uncemented total hip arthroplasty

Author keywords

Collared; Collarless; Total hip arthroplasty; Uncemented

Indexed keywords

HEPARIN; TITANIUM;

EID: 0031544462     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(97)90023-1     Document Type: Article
Times cited : (40)

References (20)
  • 1
    • 13044264915 scopus 로고
    • Disuse atrophy and adaptive remodeling in the implant-carrying proximal femur
    • Heinke G: Disuse atrophy and adaptive remodeling in the implant-carrying proximal femur. Semin Arthroplasty 4:261, 1993
    • (1993) Semin Arthroplasty , vol.4 , pp. 261
    • Heinke, G.1
  • 2
    • 0023739914 scopus 로고
    • The effects of the collar on total hip femoral component subsidence
    • Whiteside LA, Amador D, Russell K: The effects of the collar on total hip femoral component subsidence. Clin Orthop 231:120, 1988
    • (1988) Clin Orthop , vol.231 , pp. 120
    • Whiteside, L.A.1    Amador, D.2    Russell, K.3
  • 3
    • 0027631562 scopus 로고
    • Optimum pressfit and proximal stress transfer with an improved modular design in total hip arthroplasty
    • Stiehl JB: Optimum pressfit and proximal stress transfer with an improved modular design in total hip arthroplasty. Semin Arthroplasty 4:167, 1993
    • (1993) Semin Arthroplasty , vol.4 , pp. 167
    • Stiehl, J.B.1
  • 4
    • 0027244868 scopus 로고
    • A prospective randomized study of a collar versus a collarless femoral prosthesis
    • Kelley SS, Fitzgerald RH, Rand JA, Ilstrup DM: A prospective randomized study of a collar versus a collarless femoral prosthesis. Clin Orthop 294:114, 1993
    • (1993) Clin Orthop , vol.294 , pp. 114
    • Kelley, S.S.1    Fitzgerald, R.H.2    Rand, J.A.3    Ilstrup, D.M.4
  • 5
    • 0026438865 scopus 로고
    • Is it advantageous to strengthen the cement-metal interface and use a collar for cemented femoral components of total hip replacement?
    • Harris WH: Is it advantageous to strengthen the cement-metal interface and use a collar for cemented femoral components of total hip replacement? Clin Orthop 285:67, 1992
    • (1992) Clin Orthop , vol.285 , pp. 67
    • Harris, W.H.1
  • 6
    • 84889101760 scopus 로고
    • Strain alterations in the proximal femur with an uncemented femoral prosthesis emphasizing the effect of component fixation
    • Atlanta, GA, February
    • Jasty M, Henshaw RM, O'Connor DO: Strain alterations in the proximal femur with an uncemented femoral prosthesis emphasizing the effect of component fixation. p. 335. In: Proceedings of the Orthopaedic Research Society, Atlanta, GA, February 1988
    • (1988) Proceedings of the Orthopaedic Research Society , pp. 335
    • Jasty, M.1    Henshaw, R.M.2    O'Connor, D.O.3
  • 7
    • 0021359644 scopus 로고
    • The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component
    • Lewis JL, Askew MJ, Wixson RL et al: The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component. J Bone Joint Surg 66A:280, 1984
    • (1984) J Bone Joint Surg , vol.66 A , pp. 280
    • Lewis, J.L.1    Askew, M.J.2    Wixson, R.L.3
  • 8
    • 0017837076 scopus 로고
    • Proximal strain distribution in the loaded femur
    • Oh I, Harris WH: Proximal strain distribution in the loaded femur. J Bone Joint Surg 60A:75, 1978
    • (1978) J Bone Joint Surg , vol.60 A , pp. 75
    • Oh, I.1    Harris, W.H.2
  • 9
    • 9444237618 scopus 로고
    • Effects of materials, stem geometry, and collar-calcar contact on stress distribution in the proximal femur with total hip arthroplasty
    • Tarr RR, Lewis JL, Sarmiento A et al: Effects of materials, stem geometry, and collar-calcar contact on stress distribution in the proximal femur with total hip arthroplasty. Trans Orthop Res Soc, 24:34, 1979
    • (1979) Trans Orthop Res Soc , vol.24 , pp. 34
    • Tarr, R.R.1    Lewis, J.L.2    Sarmiento, A.3
  • 10
    • 0019126005 scopus 로고
    • The effect of calcar contact on femoral component micromovement
    • Markolf KL, Amstutz HC, Hirschowik DL: The effect of calcar contact on femoral component micromovement. J Bone Joint Surg 62:1315, 1980
    • (1980) J Bone Joint Surg , vol.62 , pp. 1315
    • Markolf, K.L.1    Amstutz, H.C.2    Hirschowik, D.L.3
  • 12
    • 0026452452 scopus 로고
    • The use of a collar and precoating on cemented femoral stems is unnecessary and detrimental
    • Ling RSM: The use of a collar and precoating on cemented femoral stems is unnecessary and detrimental. Clin Orthop 285:73, 1992
    • (1992) Clin Orthop , vol.285 , pp. 73
    • Ling, R.S.M.1
  • 13
    • 0028874286 scopus 로고
    • The effect of the medial collar in total hip arthroplasty with porous-coated components inserted without cement
    • Cheng SL, Davey JR, Inman RD et al: The effect of the medial collar in total hip arthroplasty with porous-coated components inserted without cement. J Bone Joint Surg 77:118, 1995
    • (1995) J Bone Joint Surg , vol.77 , pp. 118
    • Cheng, S.L.1    Davey, J.R.2    Inman, R.D.3
  • 14
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty
    • Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. J Bone Joint Surg 51A:737, 1969
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737
    • Harris, W.H.1
  • 15
    • 0020524990 scopus 로고
    • Hip arthroplasty with a Moore prosthesis with porous coating
    • Engh CA: Hip arthroplasty with a Moore prosthesis with porous coating. Clin Orthop 176:52, 1983
    • (1983) Clin Orthop , vol.176 , pp. 52
    • Engh, C.A.1
  • 16
    • 0023240947 scopus 로고
    • Porous-coated hip replacement: The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh CA, Bobyn JD, Glassman AH: Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg 69B:45, 1987
    • (1987) J Bone Joint Surg , vol.69 B , pp. 45
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 17
    • 0018687995 scopus 로고
    • Modes of failure of cemented stem-type femoral components
    • Gruen TA, McNeice GM, Amstutz HC: Modes of failure of cemented stem-type femoral components. Clin Orthop 141:17, 1979
    • (1979) Clin Orthop , vol.141 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 18
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 257:107, 1990
    • (1990) Clin Orthop , vol.257 , pp. 107
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 19
    • 0021992636 scopus 로고
    • Osteolytic changes in the upper femoral shaft following porous-coated hip replacement
    • Brown IW, Ring PA: Osteolytic changes in the upper femoral shaft following porous-coated hip replacement. J Bone Joint Surg 67B:218, 1985
    • (1985) J Bone Joint Surg , vol.67 B , pp. 218
    • Brown, I.W.1    Ring, P.A.2
  • 20
    • 0022971119 scopus 로고
    • Femoral prosthetic subsidence after low-friction arthroplasty
    • London JR: Femoral prosthetic subsidence after low-friction arthroplasty. Clin Orthop 211:134, 1986
    • (1986) Clin Orthop , vol.211 , pp. 134
    • London, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.