메뉴 건너뛰기




Volumn 10, Issue 3, 1997, Pages 153-159

Heat conduction of fixator pins with polymethylmethacrylate external fixation

Author keywords

External fixation; Polymethylmethacrylate; Thermal injury

Indexed keywords


EID: 0031535564     PISSN: 09320814     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-0038-1632587     Document Type: Article
Times cited : (11)

References (39)
  • 1
    • 0022312991 scopus 로고
    • Burn Wound Pathophysiology and Care
    • Achauer B, Martinez S. Burn Wound Pathophysiology and Care. Critical Care Clinics 1985; 1: 1: 47-58.
    • (1985) Critical Care Clinics , vol.1 , Issue.1 , pp. 47-58
    • Achauer, B.1    Martinez, S.2
  • 3
    • 0000659796 scopus 로고
    • The Temperature Dependence of the Deformation of Bone
    • Bonfield W, Li C. The Temperature Dependence of the Deformation of Bone. J Biomech 1968; 1: 323-9.
    • (1968) J Biomech , vol.1 , pp. 323-329
    • Bonfield, W.1    Li, C.2
  • 4
    • 0022757758 scopus 로고
    • Dependence of Curing Time, Peak Temperature, and Mechanical Properties on the Composition of Bone Cement
    • Brauer G, Steinberger D, Stansbury J. Dependence of Curing Time, Peak Temperature, and Mechanical Properties on the Composition of Bone Cement. J Biomed Mater Res 1986; 20: 839-52.
    • (1986) J Biomed Mater Res , vol.20 , pp. 839-852
    • Brauer, G.1    Steinberger, D.2    Stansbury, J.3
  • 6
    • 72849167386 scopus 로고
    • Anchorage of the Femoral Head Prosthesis to the Shaft of the Femur
    • Charnley J. Anchorage of the Femoral Head Prosthesis to the Shaft of the Femur. J Bone Joint Surg 1960; 42B: 1: 28-30.
    • (1960) J Bone Joint Surg , vol.42 B , Issue.1 , pp. 28-30
    • Charnley, J.1
  • 7
    • 0000473395 scopus 로고
    • A Biomechanical Analysis of the Use of Cement to Anchor the Femoral Head Prosthesis
    • Charnley J. A Biomechanical Analysis of the Use of Cement to Anchor the Femoral Head Prosthesis. J Bone Joint Surg 1965; 47B: 2: 354-63.
    • (1965) J Bone Joint Surg , vol.47 B , Issue.2 , pp. 354-363
    • Charnley, J.1
  • 8
    • 3242843199 scopus 로고
    • Hyperthermia and Cancer
    • Core D. Hyperthermia and Cancer. Comp Cont Educ Pract Vet 1982; 4: 9: 719-22.
    • (1982) Comp Cont Educ Pract Vet , vol.4 , Issue.9 , pp. 719-722
    • Core, D.1
  • 9
    • 0018445431 scopus 로고
    • Methylmethacrylate: Uses and Complications
    • Deyerle W, Crossland S, Sullivan H. Methylmethacrylate: Uses and Complications. AORN Journal 1979; 29: 4: 696-711.
    • (1979) AORN Journal , vol.29 , Issue.4 , pp. 696-711
    • Deyerle, W.1    Crossland, S.2    Sullivan, H.3
  • 10
    • 0017049822 scopus 로고
    • The Temperature Problem at the Bone Acrylic Cement Interface of the Total Hip Replacement
    • DiPisa J, Sih G, Berman A. The Temperature Problem at the Bone Acrylic Cement Interface of the Total Hip Replacement. Clin Orthop Rel Res 1976; 121: 95-8.
    • (1976) Clin Orthop Rel Res , vol.121 , pp. 95-98
    • Dipisa, J.1    Sih, G.2    Berman, A.3
  • 11
    • 0016651077 scopus 로고
    • Side Effects of Acrylic Cement Implanted into Bone
    • Feith R. Side Effects of Acrylic Cement Implanted Into Bone. Acta Orthop Scand Supp 1975; 161: 10-30.
    • (1975) Acta Orthop Scand Supp , vol.161 , pp. 10-30
    • Feith, R.1
  • 13
    • 0016740277 scopus 로고
    • A Characterization of Polymethylmethacrylate Bone Cement
    • Haas S, Brauer G, Dickson G. A Characterization of Polymethylmethacrylate Bone Cement. J Bone Joint Surg 1975; 57A: 3: 380-91.
    • (1975) J Bone Joint Surg , vol.57 A , Issue.3 , pp. 380-391
    • Haas, S.1    Brauer, G.2    Dickson, G.3
  • 14
    • 0016712745 scopus 로고
    • Hyperthermia: Biological Studies at the Cellular Level
    • Harisladis L, Hall E, Kraljevic U, Borek C. Hyperthermia: Biological Studies at the Cellular Level. Radiology 1975; 117: 447-52.
    • (1975) Radiology , vol.117 , pp. 447-452
    • Harisladis, L.1    Hall, E.2    Kraljevic, U.3    Borek, C.4
  • 15
    • 0026411042 scopus 로고
    • A Method for Bone Cement Interface Thermometry
    • Harving S, Soballe K, Bunger C. A Method for Bone Cement Interface Thermometry. Acta Orthop Scand 1991; 62: 6: 546-8.
    • (1991) Acta Orthop Scand , vol.62 , Issue.6 , pp. 546-548
    • Harving, S.1    Soballe, K.2    Bunger, C.3
  • 16
    • 0000518925 scopus 로고
    • Studies of Thermal Injury: Part 1: the Conduction of Heat to and through Skin and the Temperatures Attained Therein. A Theoretical and an Experimental Investigation
    • Henriques F, Moritz A. Studies of Thermal Injury: Part 1: The Conduction of Heat to and through Skin and the Temperatures Attained Therein. A Theoretical and an Experimental Investigation. Am J Path 1947; 23: 531-49.
    • (1947) Am J Path , vol.23 , pp. 531-549
    • Henriques, F.1    Moritz, A.2
  • 17
    • 0016776324 scopus 로고
    • Thermal Aspects of Self Curing Polymethylmethacrylate
    • Jefferiss C, Lee A, Ling R. Thermal Aspects of Self Curing Polymethylmethacrylate. J Bone Joint Surg 1975; 57B: 4: 511-8.
    • (1975) J Bone Joint Surg , vol.57 B , Issue.4 , pp. 511-518
    • Jefferiss, C.1    Lee, A.2    Ling, R.3
  • 19
    • 0016752522 scopus 로고
    • The Influence of Acrylic Bone Cement on the Femur of the Dog
    • Lindwer J, Van de Hooff A. The Influence of Acrylic Bone Cement on the Femur of the Dog. Acta Orthop Scand 1975; 46: 657-71.
    • (1975) Acta Orthop Scand , vol.46 , pp. 657-671
    • Lindwer, J.1    Van De Hooff, A.2
  • 20
    • 3242837962 scopus 로고
    • The Dissipation of Heat during Polymerization of Acrylics Used for External Skeletal Fixator Connecting Bars
    • Abstract 50
    • Martinez S, Arnoczky S, Flo G, Brinker W. The Dissipation of Heat During Polymerization of Acrylics Used for External Skeletal Fixator Connecting Bars. Abstract 50, ACVS Proceedings, 1995.
    • (1995) ACVS Proceedings
    • Martinez, S.1    Arnoczky, S.2    Flo, G.3    Brinker, W.4
  • 21
    • 0021169798 scopus 로고
    • The Thermal Effects of Skeletal Fixation Pin Insertion in Bone
    • Matthews L, Green C, Goldstein S. The Thermal Effects of Skeletal Fixation Pin Insertion in Bone. J Bone Joint Surg 1984; 66A: 7: 1077-83.
    • (1984) J Bone Joint Surg , vol.66 A , Issue.7 , pp. 1077-1083
    • Matthews, L.1    Green, C.2    Goldstein, S.3
  • 22
    • 0026667275 scopus 로고
    • Measurement of the Heat of Reaction Transmitted Intracranially during Polymerization of Methylmethacrylate Cranial Bone Cement Used in Stabilization of the Fossa Component of an Alloplastic Temporomandibular Joint Prosthesis
    • Mercuri L. Measurement of the Heat of Reaction Transmitted Intracranially During Polymerization of Methylmethacrylate Cranial Bone Cement Used in Stabilization of the Fossa Component of an Alloplastic Temporomandibular Joint Prosthesis. Oral Surg Oral Med Oral Path 1992; 74: 2: 137-42.
    • (1992) Oral Surg Oral Med Oral Path , vol.74 , Issue.2 , pp. 137-142
    • Mercuri, L.1
  • 23
    • 0015538255 scopus 로고
    • On the Setting Properties of Acrylic Bone Cement
    • Meyer P, Lautenschlager E, Moore B. On the Setting Properties of Acrylic Bone Cement. J Bone Joint Surg 1973; 55A: 1: 149-56.
    • (1973) J Bone Joint Surg , vol.55 A , Issue.1 , pp. 149-156
    • Meyer, P.1    Lautenschlager, E.2    Moore, B.3
  • 24
    • 84953656097 scopus 로고
    • Studies of Thermal Injury. Part 2: The Relative Importance of Time and Surface Temperature in the Causation of Cutaneous Burns
    • Moritz A, Henriques F. Studies of Thermal Injury. Part 2: The Relative Importance of Time and Surface Temperature in the Causation of Cutaneous Burns. Am J Path 1947; 23: 695-720.
    • (1947) Am J Path , vol.23 , pp. 695-720
    • Moritz, A.1    Henriques, F.2
  • 25
    • 3242850959 scopus 로고
    • Facial Reconstruction with Acrylic Resin
    • Munson F, Heron D. Facial Reconstruction with Acrylic Resin. Am J Surg 1941; 53: 2: 291-5.
    • (1941) Am J Surg , vol.53 , Issue.2 , pp. 291-295
    • Munson, F.1    Heron, D.2
  • 26
    • 0023869806 scopus 로고
    • Use of Methyl Methacrylate Orbital Prostheses in Dogs and Cats: 78 Cases (1980-1986)
    • Nasisse M, Van Ee R, Munger R, Davidson M. Use of Methyl Methacrylate Orbital Prostheses in Dogs and Cats: 78 Cases (1980-1986). JAVMA 1988; 192: 4: 539-42.
    • (1988) JAVMA , vol.192 , Issue.4 , pp. 539-542
    • Nasisse, M.1    Van Ee, R.2    Munger, R.3    Davidson, M.4
  • 27
    • 0020609477 scopus 로고
    • External Skeletal Fixation Using Methylmethacrylate
    • Ohashi T, Inoue S, Kajikawa K. External Skeletal Fixation Using Methylmethacrylate. Clin Orthop Rel Res 1983; 178: 121-9.
    • (1983) Clin Orthop Rel Res , vol.178 , pp. 121-129
    • Ohashi, T.1    Inoue, S.2    Kajikawa, K.3
  • 28
    • 0026285367 scopus 로고
    • Biomechanical Evaluation of Acrylic External Skeletal Fixation in Dogs and Cats
    • Okrasinski E, Pardo A, Graehler R. Biomechanical Evaluation of Acrylic External Skeletal Fixation in Dogs and Cats. JAVMA 1991; 199: 11: 1590-3.
    • (1991) JAVMA , vol.199 , Issue.11 , pp. 1590-1593
    • Okrasinski, E.1    Pardo, A.2    Graehler, R.3
  • 30
    • 0017344948 scopus 로고
    • The Bone Cement Interface Temperature during Total Joint Replacement
    • Reckling F, Dillon W. The Bone Cement Interface Temperature During Total Joint Replacement. J Bone Joint Surg 1977; 59A: 1: 80-2.
    • (1977) J Bone Joint Surg , vol.59 A , Issue.1 , pp. 80-82
    • Reckling, F.1    Dillon, W.2
  • 32
    • 0001196911 scopus 로고
    • Intra-ocular Acrylic Lenses: A Recent Development in the Surgery of Cataract
    • Ridley H. Intra-ocular Acrylic Lenses: A Recent Development in the Surgery of Cataract. Brit J Ophthal 1952; 36: 113-22.
    • (1952) Brit J Ophthal , vol.36 , pp. 113-122
    • Ridley, H.1
  • 33
    • 0021412468 scopus 로고
    • Mechanical Properties of Bone Cement: A Review
    • Saha S, Pal S. Mechanical Properties of Bone Cement: A Review. J Biomed Mater Res 1984; 18: 435-62.
    • (1984) J Biomed Mater Res , vol.18 , pp. 435-462
    • Saha, S.1    Pal, S.2
  • 36
    • 0023214373 scopus 로고
    • Thermal . Effects of Polymerization of Methylmethacrylate on Small Tubular Bones
    • Schultz R, Johnston A, Krishnamurthy S. Thermal . Effects of Polymerization of Methylmethacrylate on Small Tubular Bones. International Orthop 1987; 11: 277-82.
    • (1987) International Orthop , vol.11 , pp. 277-282
    • Schultz, R.1    Johnston, A.2    Krishnamurthy, S.3
  • 37
    • 0040031355 scopus 로고
    • Acrylic External Skeletal Fixation of Fractures
    • Tomlinson J, Constantinescu G. Acrylic External Skeletal Fixation of Fractures. Comp Cont Educ Pract Vet 1991; 13: 2: 235-40.
    • (1991) Comp Cont Educ Pract Vet , vol.13 , Issue.2 , pp. 235-240
    • Tomlinson, J.1    Constantinescu, G.2
  • 38
    • 0019572149 scopus 로고
    • Molecular and Macroscopic Properties of PMMA Bone Cement: Free Radical Generation and Temperature. Change Versus Mixing Ratio
    • Turner R, Atkins P, Ackley M, Park J. Molecular and Macroscopic Properties of PMMA Bone Cement: Free Radical Generation and Temperature. Change Versus Mixing Ratio. J Biomed Mater Res 1981; 15: 425-32.
    • (1981) J Biomed Mater Res , vol.15 , pp. 425-432
    • Turner, R.1    Atkins, P.2    Ackley, M.3    Park, J.4
  • 39
    • 0000704086 scopus 로고
    • Comparison of Stainless Steel Versus Acrylic for the Connecting Bar of External Skeletal Fixators
    • Willer R, Egger E, Histand M. Comparison of Stainless Steel Versus Acrylic for the Connecting Bar of External Skeletal Fixators. JAAHA 1991; 27: 541-8.
    • (1991) JAAHA , vol.27 , pp. 541-548
    • Willer, R.1    Egger, E.2    Histand, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.