메뉴 건너뛰기




Volumn 53, Issue 5, 1997, Pages 258-270

Selection criteria and quality requirements for testing equipement;Quel equipement choisir, sur quels criteres, avec quelles exigences?

Author keywords

Analyzers; Capters; Ergometers; Testing systems

Indexed keywords

ACCURACY; ANEMOMETRY; CARBON DIOXIDE TENSION; DYSPNEA; ERGOMETER; EXERCISE TEST; HUMAN; INFORMATION PROCESSING; LUNG VENTILATION; LUNG VOLUME; MEDICAL INSTRUMENTATION; OXYGEN TENSION; PNEUMOTACHYGRAPHY; RELIABILITY; REVIEW; EXERCISE TOLERANCE; INSTRUMENTATION; QUALITY CONTROL;

EID: 0031470613     PISSN: 00325821     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (1)

References (66)
  • 1
    • 0023183162 scopus 로고
    • The role of exercise testing in pulmonary diagnosis
    • Ries A.L. : The role of exercise testing in pulmonary diagnosis. Clin Chest Medicine 1987, 8, 81-89.
    • (1987) Clin Chest Medicine , vol.8 , pp. 81-89
    • Ries, A.L.1
  • 3
    • 0015759077 scopus 로고
    • Water vapor corrections in oxygen consumption calculations
    • Beaver W.L. : Water vapor corrections in oxygen consumption calculations. J. Appl. Physiol., 1973, 35, 928-931.
    • (1973) J. Appl. Physiol. , vol.35 , pp. 928-931
    • Beaver, W.L.1
  • 4
    • 0016252441 scopus 로고
    • Semiautomated systems approach to the assesment of oxygen uptake during exercise
    • Wilmore J.H., Costill D.L. : Semiautomated systems approach to the assesment of oxygen uptake during exercise. J. Appl. Physiol., 1974, 36, 618-620.
    • (1974) J. Appl. Physiol. , vol.36 , pp. 618-620
    • Wilmore, J.H.1    Costill, D.L.2
  • 6
    • 0016687806 scopus 로고
    • Validation of continuous determination of respired gases during steady-state exercise
    • Poole G.W., Maskrell R.C. : Validation of continuous determination of respired gases during steady-state exercise. J. Appl. Physiol., 1975, 38, 736-738.
    • (1975) J. Appl. Physiol. , vol.38 , pp. 736-738
    • Poole, G.W.1    Maskrell, R.C.2
  • 7
    • 0016156340 scopus 로고
    • An increasing work rate test for assessing the physiological strain of submaximal exercise
    • Spiro S.G., Juniper E., Bowman P., Edwrds R.H.T. : An increasing work rate test for assessing the physiological strain of submaximal exercise. Clin. Sci. Mol. Med., 1974, 46, 191-206.
    • (1974) Clin. Sci. Mol. Med. , vol.46 , pp. 191-206
    • Spiro, S.G.1    Juniper, E.2    Bowman, P.3    Edwrds, R.H.T.4
  • 8
    • 0015547883 scopus 로고
    • On-line computer analysis and breath-by-breath graphical display of exercise function tests
    • Beaver W.L., Wasserman K., Whipp B.J. : On-line computer analysis and breath-by-breath graphical display of exercise function tests. J. Appl. Physiol., 1973, 34, 128-132.
    • (1973) J. Appl. Physiol. , vol.34 , pp. 128-132
    • Beaver, W.L.1    Wasserman, K.2    Whipp, B.J.3
  • 9
    • 0019976843 scopus 로고
    • Breath-by-breath VCO2 and VO2 require compensation for transport delay and dynamic response
    • Nogucchi H., Ogushi Y., Yoshiya I., Itakura N., Yamabayashi H. : Breath-by-breath VCO2 and VO2 require compensation for transport delay and dynamic response. J. Appl. Physiol., 1982, 52, 79-84.
    • (1982) J. Appl. Physiol. , vol.52 , pp. 79-84
    • Nogucchi, H.1    Ogushi, Y.2    Yoshiya, I.3    Itakura, N.4    Yamabayashi, H.5
  • 11
    • 0019782367 scopus 로고
    • Breath-by-breath measurement of true alveolar gas exchange
    • Beaver W.L., Lamarra N., Wasserman K. : Breath-by-breath measurement of true alveolar gas exchange. J. Appl. Physiol., 1981, 51, 1662-1675.
    • (1981) J. Appl. Physiol. , vol.51 , pp. 1662-1675
    • Beaver, W.L.1    Lamarra, N.2    Wasserman, K.3
  • 12
    • 0018975448 scopus 로고
    • Measurement and analysis of gas exchange during exercise using a programmable calculator
    • Sue D.Y., Hansen J.E., Blias M., Wasserman K. : Measurement and analysis of gas exchange during exercise using a programmable calculator. J. Appl. Physiol., 1980, 49, 456-461.
    • (1980) J. Appl. Physiol. , vol.49 , pp. 456-461
    • Sue, D.Y.1    Hansen, J.E.2    Blias, M.3    Wasserman, K.4
  • 15
    • 0002172680 scopus 로고
    • Breath-by-breath considerations for gas exchange kinetics
    • Edited by P Ceretelli and BJ Whipp. Amsterdam : Elsevier/North Holland
    • Swanson G.D. : Breath-by-breath considerations for gas exchange kinetics. In : Exercise Bioenergetics and gas exchange. Edited by P Ceretelli and BJ Whipp. Amsterdam : Elsevier/North Holland. 1980, p 211-222.
    • (1980) Exercise Bioenergetics and Gas Exchange , pp. 211-222
    • Swanson, G.D.1
  • 16
    • 0023442646 scopus 로고
    • Official Statement of the American Thoracic Society. Standardization of spirometry - 1987 update
    • Official Statement of the American Thoracic Society. Standardization of spirometry - 1987 update. Am. Rev. Respir. Dis., 1987, 136, 1285-1298.
    • (1987) Am. Rev. Respir. Dis. , vol.136 , pp. 1285-1298
  • 17
    • 0015263427 scopus 로고
    • Linearity and frequency response of pneumotachographs
    • Finucane K.E., Egan B.A., Dawson S.V. : Linearity and frequency response of pneumotachographs. J. Appl. Physiol., 1972, 32, 121-126.
    • (1972) J. Appl. Physiol. , vol.32 , pp. 121-126
    • Finucane, K.E.1    Egan, B.A.2    Dawson, S.V.3
  • 18
    • 0022204458 scopus 로고
    • Linearity and temperature control of the Fleisch pneumotachograph
    • Miller M.R., Pincock A.C. : Linearity and temperature control of the Fleisch pneumotachograph. J. Appl. Physiol., 1986, 60, 710-715.
    • (1986) J. Appl. Physiol. , vol.60 , pp. 710-715
    • Miller, M.R.1    Pincock, A.C.2
  • 19
    • 0023628720 scopus 로고
    • Turbine flow meter versus Fleisch pneumotachometer : A comparative study for exercise testing
    • Yeh M.P., Adams T.D., Gardner R.M., Yanowitz F.G. : Turbine flow meter versus Fleisch pneumotachometer : a comparative study for exercise testing. J. Appl. Physiol., 1987, 63, 1289-1295.
    • (1987) J. Appl. Physiol. , vol.63 , pp. 1289-1295
    • Yeh, M.P.1    Adams, T.D.2    Gardner, R.M.3    Yanowitz, F.G.4
  • 20
    • 0028577331 scopus 로고
    • Evaluation of a symmetrically disposed Pilot tube flowmeter for measuring gas flow during exercise
    • Porszasz J., Barstow T.J., Wasserman K. : Evaluation of a symmetrically disposed Pilot tube flowmeter for measuring gas flow during exercise. J. Appl. Physiol., 1994, 77, 2659-26657.
    • (1994) J. Appl. Physiol. , vol.77 , pp. 2659-26657
    • Porszasz, J.1    Barstow, T.J.2    Wasserman, K.3
  • 21
    • 0016631524 scopus 로고
    • A bidirectional respiratory flowmeter using the hot-wire principle
    • Yoshiya I., Nakajima T., Nagai I., Jitsukawa S. : A bidirectional respiratory flowmeter using the hot-wire principle. J. Appl. Physiol., 1975, 38, 360-365.
    • (1975) J. Appl. Physiol. , vol.38 , pp. 360-365
    • Yoshiya, I.1    Nakajima, T.2    Nagai, I.3    Jitsukawa, S.4
  • 22
    • 0018627277 scopus 로고
    • Evaluation of a hot-wire respiratory flowmeter for clinical applicability
    • Yoshiya I., Shimada Y., Tanaka K. : Evaluation of a hot-wire respiratory flowmeter for clinical applicability. J. Appl. Physiol., 1979, 47, 1131-1135.
    • (1979) J. Appl. Physiol. , vol.47 , pp. 1131-1135
    • Yoshiya, I.1    Shimada, Y.2    Tanaka, K.3
  • 23
    • 0025245482 scopus 로고
    • Evaluation of a turbine flowmeter (Ventilometer Mark 2) in the measurement of ventilation
    • Cooper C.B., Harris N.D., Howard P. : Evaluation of a turbine flowmeter (Ventilometer Mark 2) in the measurement of ventilation. Respiration, 1990, 57, 243-247.
    • (1990) Respiration , vol.57 , pp. 243-247
    • Cooper, C.B.1    Harris, N.D.2    Howard, P.3
  • 25
    • 0018454707 scopus 로고
    • Specification for exercise testing equipment
    • American Heart Association Subcommittee on Rehabilitation Target Activity Group (Hellerstein HK, chairman). Specification for exercise testing equipment. Circulation, 1979, 59, 849A-854A.
    • (1979) Circulation , vol.59
    • Hellerstein, H.K.1
  • 26
    • 0025650842 scopus 로고
    • Exercise standards. A statement for health professionals from the American Heart Association
    • Fletcher G.B., Froelicher V.F., Hartley L.H., Haskell W.L., Pollack M.L. : Exercise standards. A statement for health professionals from the American Heart Association. Circulation, 1990, 82, 2286-2322.
    • (1990) Circulation , vol.82 , pp. 2286-2322
    • Fletcher, G.B.1    Froelicher, V.F.2    Hartley, L.H.3    Haskell, W.L.4    Pollack, M.L.5
  • 27
    • 0026062136 scopus 로고
    • Blood pressure monitoring : Automated oscillometric devices
    • Ramsey M. : Blood pressure monitoring : automated oscillometric devices. J. Clin. Monit., 1991, 7, 56-67.
    • (1991) J. Clin. Monit. , vol.7 , pp. 56-67
    • Ramsey, M.1
  • 28
    • 0021368736 scopus 로고
    • Predicted values for clinical exercise testing
    • Hansen J.E., Sue D.Y., Wasserman K. : Predicted values for clinical exercise testing. Am. Rev. Respir. Dis., 1984, 129 (suppl) : S49-S55.
    • (1984) Am. Rev. Respir. Dis. , vol.129 , Issue.SUPPL.
    • Hansen, J.E.1    Sue, D.Y.2    Wasserman, K.3
  • 31
    • 0027200540 scopus 로고
    • The use of pulse oximetry during conscious sedation
    • Council on Scientific Affairs, American Medical Association. The use of pulse oximetry during conscious sedation. JAMA, 1993, 270, 1463-1468.
    • (1993) JAMA , vol.270 , pp. 1463-1468
  • 32
    • 0025298928 scopus 로고
    • Respiratory monitoring
    • Tobin M.J. : Respiratory monitoring. JAMA, 1990, 264, 244-251.
    • (1990) JAMA , vol.264 , pp. 244-251
    • Tobin, M.J.1
  • 33
    • 0021872423 scopus 로고
    • Accuracy of two ear oximeters at rest and during exercise in pulmonary patients
    • Ries A.L., Farrow J.T., Clausen J.L. : Accuracy of two ear oximeters at rest and during exercise in pulmonary patients. Am. Rev. Respir. Dis., 1985, 132, 685-689.
    • (1985) Am. Rev. Respir. Dis. , vol.132 , pp. 685-689
    • Ries, A.L.1    Farrow, J.T.2    Clausen, J.L.3
  • 34
  • 35
    • 0026328123 scopus 로고
    • Reliability of noninvasive oximetry in black subjects during exercise and hypoxia
    • Zeballos R.J., Weisman I.M. : Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Am. Rev. Respir. Dis.. 1991, 144, 1240-1244.
    • (1991) Am. Rev. Respir. Dis.. , vol.144 , pp. 1240-1244
    • Zeballos, R.J.1    Weisman, I.M.2
  • 36
    • 0023718959 scopus 로고
    • The use of cutaneous oximetry in the prescription of long-term oxygen therapy
    • Carlin B.W., Clausen J.S., Ries A.L. : The use of cutaneous oximetry in the prescription of long-term oxygen therapy. Chest, 1988, 94, 239-241.
    • (1988) Chest , vol.94 , pp. 239-241
    • Carlin, B.W.1    Clausen, J.S.2    Ries, A.L.3
  • 37
    • 0027504542 scopus 로고
    • Accuracy of three pulse oximeters during exercise and hypoxemia in patients with cystic fibrosis
    • Orenstein D.M., Curtis S.E., Nixon P.A., Hartigan E.R. : Accuracy of three pulse oximeters during exercise and hypoxemia in patients with cystic fibrosis. Chest, 1993, 104, 1187-1190.
    • (1993) Chest , vol.104 , pp. 1187-1190
    • Orenstein, D.M.1    Curtis, S.E.2    Nixon, P.A.3    Hartigan, E.R.4
  • 38
    • 0027978643 scopus 로고
    • The effects of exercise testing on the prescription of oxygen therapy
    • Carlin B.W., Clausen J.S., Ries A.L. : The effects of exercise testing on the prescription of oxygen therapy. Chest, 1994, 106, 361-365.
    • (1994) Chest , vol.106 , pp. 361-365
    • Carlin, B.W.1    Clausen, J.S.2    Ries, A.L.3
  • 39
    • 0023130340 scopus 로고
    • Validity of ear oximetry in clinicalexercise testing
    • Hansen J.E., Casaburi R. : Validity of ear oximetry in clinicalexercise testing. Chest, 1987, 91, 333-337.
    • (1987) Chest , vol.91 , pp. 333-337
    • Hansen, J.E.1    Casaburi, R.2
  • 40
    • 0014440852 scopus 로고
    • Oxygen uptake during maximal treadmill and bicycle exercise
    • Hermansen L., Saltin B. : Oxygen uptake during maximal treadmill and bicycle exercise. J. Appl. Physiol., 1969, 26, 1-31
    • (1969) J. Appl. Physiol. , vol.26 , pp. 1-31
    • Hermansen, L.1    Saltin, B.2
  • 41
    • 0015808488 scopus 로고
    • Comparison of continuous and discontinuous treadmill and bicycle tests for max VO2
    • Mac Ardle W.D., Katch R.J., Pechar G.S.: Comparison of continuous and discontinuous treadmill and bicycle tests for max VO2. Med. Sci. Sports, 1973, 5, 3, 156.
    • (1973) Med. Sci. Sports , vol.5 , Issue.3 , pp. 156
    • Mac Ardle, W.D.1    Katch, R.J.2    Pechar, G.S.3
  • 42
    • 0017134953 scopus 로고
    • A comparison of maximum oxygen uptake determination by bicycle ergometry ay various pedaling frequencies and by treadmill running at various speed
    • Mac Kay G.A., Banister E.W. : A comparison of maximum oxygen uptake determination by bicycle ergometry ay various pedaling frequencies and by treadmill running at various speed. Europ J. Appl. Physiol., 1976, 35, 191.
    • (1976) Europ J. Appl. Physiol. , vol.35 , pp. 191
    • Mac Kay, G.A.1    Banister, E.W.2
  • 43
    • 0017074332 scopus 로고
    • Ventilatory responses to the metabolicacidosis of treadmill and cycle ergometry
    • Koyal S.N., Whipp B.J., Huntsman D., Bray G.A., Wasserman K. : Ventilatory responses to the metabolicacidosis of treadmill and cycle ergometry. J. Appl. Physiol., 1976, 40, 864-867.
    • (1976) J. Appl. Physiol. , vol.40 , pp. 864-867
    • Koyal, S.N.1    Whipp, B.J.2    Huntsman, D.3    Bray, G.A.4    Wasserman, K.5
  • 45
    • 0013642850 scopus 로고
    • Exercise energetics and respiratory control in man following acute and chronic elevation of calorie intake
    • Ed. Bray GA, Washington DC. Sect II, Chapter 20. US Govt Printing Office
    • Whipp B.J., Bray G.A., Koyal S.N., Wasserman K. : Exercise energetics and respiratory control in man following acute and chronic elevation of calorie intake. In : Ed. Bray GA, Washington DC. Obesity in Perspective, Sect II, Chapter 20. US Govt Printing Office 1976, 157-163.
    • (1976) Obesity in Perspective , pp. 157-163
    • Whipp, B.J.1    Bray, G.A.2    Koyal, S.N.3    Wasserman, K.4
  • 46
    • 0016593346 scopus 로고
    • Exercise physiology in health and disease (State of the Art)
    • Wasserman K., Whipp B.J. : Exercise physiology in health and disease (State of the Art). Am. Rev. Respir. Dis., 1975, 112, 219-249.
    • (1975) Am. Rev. Respir. Dis. , vol.112 , pp. 219-249
    • Wasserman, K.1    Whipp, B.J.2
  • 47
    • 6844250035 scopus 로고
    • A hyperbolic ergometer for cycling and cranking
    • Lanooy C., Bonjer F.H. : A hyperbolic ergometer for cycling and cranking. J. Appl, Physiol., 1956, 9, 499-500.
    • (1956) J. Appl, Physiol. , vol.9 , pp. 499-500
    • Lanooy, C.1    Bonjer, F.H.2
  • 48
    • 0019349265 scopus 로고
    • A test to determine parameters of aerobic function during exercise
    • Whipp B.J., Davis J.A., Torres F., Wasserman K. : A test to determine parameters of aerobic function during exercise. J. Appl. Physiol., 1981, 50, 217-221.
    • (1981) J. Appl. Physiol. , vol.50 , pp. 217-221
    • Whipp, B.J.1    Davis, J.A.2    Torres, F.3    Wasserman, K.4
  • 50
    • 0023848220 scopus 로고
    • Oxygen uptake as related to work rate increment during cycle ergometer exercise
    • Hansen J.E., Casaburi R., Cooper D.M., Wasserman K. : Oxygen uptake as related to work rate increment during cycle ergometer exercise. Eur J. Appl. Physiol., 1988, 57, 140-145.
    • (1988) Eur J. Appl. Physiol. , vol.57 , pp. 140-145
    • Hansen, J.E.1    Casaburi, R.2    Cooper, D.M.3    Wasserman, K.4
  • 51
    • 0025806619 scopus 로고
    • Effect of exercise testing protocol on parameters of aerobic function
    • Zhang Y.Y., Johnson M.C., Chow N., Wasserman K. : Effect of exercise testing protocol on parameters of aerobic function. Med. Sci. Sports Exerc., 1991, 23, 625-630.
    • (1991) Med. Sci. Sports Exerc. , vol.23 , pp. 625-630
    • Zhang, Y.Y.1    Johnson, M.C.2    Chow, N.3    Wasserman, K.4
  • 53
    • 0026081074 scopus 로고
    • Correlation of the physiologic parameters of a continuous ramp versus an incremental James exercise protocol in normal children
    • Tanner C.S., Heise C.T., Barber G. : Correlation of the physiologic parameters of a continuous ramp versus an incremental James exercise protocol in normal children. Am. J. Cardiol., 1991, 67, 309-312.
    • (1991) Am. J. Cardiol. , vol.67 , pp. 309-312
    • Tanner, C.S.1    Heise, C.T.2    Barber, G.3
  • 54
    • 0027075023 scopus 로고
    • Dynamic and steady-state ventilatory and gas exchange responses to arm exercise
    • Casaburi R., Barstow T.J., Robinson T., Wasserman K. : Dynamic and steady-state ventilatory and gas exchange responses to arm exercise. Med. Sci. Sports Exerc., 1992, 24, 1365-1374.
    • (1992) Med. Sci. Sports Exerc. , vol.24 , pp. 1365-1374
    • Casaburi, R.1    Barstow, T.J.2    Robinson, T.3    Wasserman, K.4
  • 55
    • 0021081981 scopus 로고
    • Aerobic requirements of arm ergometry ; implications for exercise testing and training
    • Franklin B.A., Vander L., Wrisley D., Rubenfire M. : Aerobic requirements of arm ergometry ; implications for exercise testing and training. Physician Spotsmed 1983, 11, 81-90.
    • (1983) Physician Spotsmed , vol.11 , pp. 81-90
    • Franklin, B.A.1    Vander, L.2    Wrisley, D.3    Rubenfire, M.4
  • 56
    • 0022520344 scopus 로고
    • Physiology of upper body exercise
    • Sawka M.N. : Physiology of upper body exercise. Exerc. Sports Sci. Rev., 1986, 14, 175-211.
    • (1986) Exerc. Sports Sci. Rev. , vol.14 , pp. 175-211
    • Sawka, M.N.1
  • 57
    • 0015184317 scopus 로고
    • Exercise testing of patients with coronary artery disease
    • Bruce R.A. : Exercise testing of patients with coronary artery disease. Ann. Clin. Res., 1971, 323-332.
    • (1971) Ann. Clin. Res. , pp. 323-332
    • Bruce, R.A.1
  • 58
    • 0015425884 scopus 로고
    • Treadmill exercise inassessment of patients with cardiac disease
    • Patterson J.A., Naughton J., Pietras R.J.., Gumar R.N. : Treadmill exercise inassessment of patients with cardiac disease. Am. J. Cardiol., 1972, 30, 757-762.
    • (1972) Am. J. Cardiol. , vol.30 , pp. 757-762
    • Patterson, J.A.1    Naughton, J.2    Pietras, R.J.3    Gumar, R.N.4
  • 60
    • 84873776826 scopus 로고
    • An experimental study of « physical fitness » of Air Force personnel
    • Balke B., Ware R.W. : An experimental study of « physical fitness » of Air Force personnel. US Armed Forces Med. J., 1959.
    • (1959) US Armed Forces Med. J.
    • Balke, B.1    Ware, R.W.2
  • 63
    • 0025322199 scopus 로고
    • A respiratory gas exchange simulator for routine calibration in metabolic studies
    • Huszczuk A., Whipp B.J., Wasserman K. : A respiratory gas exchange simulator for routine calibration in metabolic studies. Eur. Respir. J., 1990, 3, 465-468.
    • (1990) Eur. Respir. J. , vol.3 , pp. 465-468
    • Huszczuk, A.1    Whipp, B.J.2    Wasserman, K.3
  • 64
    • 0015028360 scopus 로고
    • Electronic bicycle ergometer : A simple calibration procedure
    • Clark J.H., Greenleaf J.E. : Electronic bicycle ergometer : a simple calibration procedure. J. Appl. Physiol., 1971, 30, 440-442.
    • (1971) J. Appl. Physiol. , vol.30 , pp. 440-442
    • Clark, J.H.1    Greenleaf, J.E.2
  • 65
    • 0026558526 scopus 로고
    • A simple calibration method for mechanically braked cycle ergometers
    • Van Praagh E., Bedu M., Roddier P., Coudert J. : A simple calibration method for mechanically braked cycle ergometers. Int. J. Sports Med., 1992, 13, 27-30.
    • (1992) Int. J. Sports Med. , vol.13 , pp. 27-30
    • Van Praagh, E.1    Bedu, M.2    Roddier, P.3    Coudert, J.4
  • 66
    • 0022534437 scopus 로고
    • Dynamic torquemeter calibration of bicycle ergometers
    • Russell J.C., Dale J.D. : Dynamic torquemeter calibration of bicycle ergometers. J. Appl. Physiol., 1986, 61, 1217-1220.
    • (1986) J. Appl. Physiol. , vol.61 , pp. 1217-1220
    • Russell, J.C.1    Dale, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.