메뉴 건너뛰기




Volumn 158, Issue 2, 1997, Pages 129-136

Preparation of polymeric microbubbles: Formulation studies and product characterisation

Author keywords

Formulation studies; Microbubbles; Physico chemical characterisation; Polymer; Ultrasound contrast agent

Indexed keywords

ALBUMIN; CAMPHENE; ECHO CONTRAST MEDIUM; POLYMER;

EID: 0031465140     PISSN: 03785173     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0378-5173(97)00228-7     Document Type: Article
Times cited : (58)

References (15)
  • 1
    • 84982017762 scopus 로고
    • Physical and biochemical characterisation of Albunex™, a new ultrasound contrast agent consisting of air-filled albumin microspheres suspended in a solution of human albumin
    • Christiansen C., Kryvi H., Sontum P.C., Skotland T. Physical and biochemical characterisation of Albunex™, a new ultrasound contrast agent consisting of air-filled albumin microspheres suspended in a solution of human albumin. Biotechnol. Appl. Biochem. 19:1994;307-320.
    • (1994) Biotechnol. Appl. Biochem. , vol.19 , pp. 307-320
    • Christiansen, C.1    Kryvi, H.2    Sontum, P.C.3    Skotland, T.4
  • 2
    • 0018305485 scopus 로고
    • Preparation of hollow spherical particles
    • Farnand J.R., Puddington I.E. Preparation of hollow spherical particles. Powder Technol. 22:1979;11-16.
    • (1979) Powder Technol. , vol.22 , pp. 11-16
    • Farnand, J.R.1    Puddington, I.E.2
  • 3
    • 0014770284 scopus 로고
    • Identification of ultrasound echoes from the left ventricle by use of intercardiac injections of indocyanine green
    • Feigenbaum H., Stone J., Lee D., Nasser W., Chang S. Identification of ultrasound echoes from the left ventricle by use of intercardiac injections of indocyanine green. Circulation. 41:1970;615-621.
    • (1970) Circulation , vol.41 , pp. 615-621
    • Feigenbaum, H.1    Stone, J.2    Lee, D.3    Nasser, W.4    Chang, S.5
  • 4
    • 0023849614 scopus 로고
    • Contrast echocardiography during coronary artiography in humans. Perfusion and anatomic studies
    • Feinstein S.B., Lang R.M., Dick C.et al. Contrast echocardiography during coronary artiography in humans. Perfusion and anatomic studies. J. Am. Coll. Cardiol. 11:1988;59-65.
    • (1988) J. Am. Coll. Cardiol. , vol.11 , pp. 59-65
    • Feinstein, S.B.1    Lang, R.M.2    Dick, C.3
  • 5
    • 0014327602 scopus 로고
    • Echocardiography of the aortic root
    • Gramiak R., Shah P.M. Echocardiography of the aortic root. Invest. Radiol. 3:1968;356-358.
    • (1968) Invest. Radiol. , vol.3 , pp. 356-358
    • Gramiak, R.1    Shah, P.M.2
  • 6
    • 0027334532 scopus 로고
    • Ultrasound scattering properties of albunex microspheres
    • de Jong N., Hoff L. Ultrasound scattering properties of albunex microspheres. Ultrasonics. 31(3):1993;175-181.
    • (1993) Ultrasonics , vol.31 , Issue.3 , pp. 175-181
    • De Jong, N.1    Hoff, L.2
  • 9
    • 0002072446 scopus 로고
    • Echo enhancers - How safe are they?.
    • In: Nanda, N.C., Sclief, R. (Eds.), Kluwer, Dordrecht
    • Nanda, N.C., 1993. Echo enhancers - how safe are they?. In: Nanda, N.C., Sclief, R. (Eds.), Advances in Echo Imaging using Contrast Enhancement. Kluwer, Dordrecht, pp. 97-110.
    • (1993) Advances in Echo Imaging Using Contrast Enhancement. , pp. 97-110
    • Nanda, N.C.1
  • 12
    • 0025789981 scopus 로고
    • A new ultrasound contrast agent based on biodegradable polymeric microballons
    • Schneider M., Bussat P., Barrau M.B.et al. A new ultrasound contrast agent based on biodegradable polymeric microballons. Invest. Radiol. 26:1991;190-191.
    • (1991) Invest. Radiol. , vol.26 , pp. 190-191
    • Schneider, M.1    Bussat, P.2    Barrau, M.B.3
  • 13
    • 0026544026 scopus 로고
    • Polymeric microballoons as ultrasound contrast agents. Physical and ultrasonic properties compared with sonicated albumin
    • Schneider M., Bussat P., Barrau M.B.et al. Polymeric microballoons as ultrasound contrast agents. Physical and ultrasonic properties compared with sonicated albumin. Invest. Radiol. 27:1992;134-139.
    • (1992) Invest. Radiol. , vol.27 , pp. 134-139
    • Schneider, M.1    Bussat, P.2    Barrau, M.B.3
  • 14
    • 0027989919 scopus 로고
    • The precision and accuracy of analysis of air filled albumin microspheres using Coulter Multisizer Mark II
    • Sontum P.C., Christiansen C. The precision and accuracy of analysis of air filled albumin microspheres using Coulter Multisizer Mark II. J. Pharm. Biomed. Anal. 12(10):1994;1233-1241.
    • (1994) J. Pharm. Biomed. Anal. , vol.12 , Issue.10 , pp. 1233-1241
    • Sontum, P.C.1    Christiansen, C.2
  • 15
    • 0030791921 scopus 로고    scopus 로고
    • Coulter counting and light diffraction analysis applied to characterisation of oil/water emulsions
    • Sontum P.C., Kolderup E.M., in't Veldt D. Coulter counting and light diffraction analysis applied to characterisation of oil/water emulsions. J. Pharm. Biomed. Anal. 15:1997;1641-1646.
    • (1997) J. Pharm. Biomed. Anal. , vol.15 , pp. 1641-1646
    • Sontum, P.C.1    Kolderup, E.M.2    In'T Veldt, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.