메뉴 건너뛰기




Volumn 42, Issue 12, 1997, Pages 2411-2420

Dose optimization of proton and heavy ion therapy using generalized sampled pattern matching

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; COLLIMATOR; HEAVY ION RADIATION; PHANTOM; PRIORITY JOURNAL; PROTON RADIATION; RADIATION DEPTH DOSE; RADIATION DOSE DISTRIBUTION; RELATIVE BIOLOGIC EFFECTIVENESS; THREE DIMENSIONAL IMAGING;

EID: 0031458250     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/42/12/008     Document Type: Article
Times cited : (13)

References (20)
  • 1
    • 0024320384 scopus 로고
    • Optimization of proton and heavy ion therapy using an adaptive inversion algorithm
    • Brahme A, Källman P and Lind B 1989 Optimization of proton and heavy ion therapy using an adaptive inversion algorithm Radiother. Oncol. 15 189-97
    • (1989) Radiother. Oncol. , vol.15 , pp. 189-197
    • Brahme, A.1    Källman, P.2    Lind, B.3
  • 2
    • 84907111624 scopus 로고
    • Electron beam dose planning using discrete Gaussian beams
    • Brahme A, Lax I and Andreo P 1981 Electron beam dose planning using discrete Gaussian beams Acta Radiol. Oncol. 20 147-58
    • (1981) Acta Radiol. Oncol. , vol.20 , pp. 147-158
    • Brahme, A.1    Lax, I.2    Andreo, P.3
  • 3
    • 0018143405 scopus 로고
    • The influence of thick inhomogeneities on charged particle beams
    • Goitein M and Sisterson J M 1978 The influence of thick inhomogeneities on charged particle beams Radiat. Res. 74 217-30
    • (1978) Radiat. Res. , vol.74 , pp. 217-230
    • Goitein, M.1    Sisterson, J.M.2
  • 5
    • 0020576688 scopus 로고
    • Broad beam three-dimensional irradiation for proton radiotherapy
    • Kanai T, Kawachi K, Matsuzawa H and Inada T 1983a Broad beam three-dimensional irradiation for proton radiotherapy Med. Phys. 10 344-6
    • (1983) Med. Phys. , vol.10 , pp. 344-346
    • Kanai, T.1    Kawachi, K.2    Matsuzawa, H.3    Inada, T.4
  • 6
    • 0345295272 scopus 로고
    • Three-dimensional beam scanning for proton therapy
    • _1983b Three-dimensional beam scanning for proton therapy Nucl. Instrum. Methods 214 491-6
    • (1983) Nucl. Instrum. Methods , vol.214 , pp. 491-496
  • 7
    • 0001719711 scopus 로고
    • Pre-therapeutic physical experiments with high energy protons
    • Larsson B 1961 Pre-therapeutic physical experiments with high energy protons Br. J. Radiol. 34 143-51
    • (1961) Br. J. Radiol. , vol.34 , pp. 143-151
    • Larsson, B.1
  • 9
    • 84909725884 scopus 로고
    • Comparison of algorithms for solving inverse problems in radiotherapy
    • paper MP 5.6
    • Lind B 1988 Comparison of algorithms for solving inverse problems in radiotherapy Book of Abstracts VIII ICMP (San Antonio, Texas) paper MP 5.6
    • (1988) Book of Abstracts VIII ICMP (San Antonio, Texas)
    • Lind, B.1
  • 10
    • 0001439788 scopus 로고
    • Properties of an algorithm for solving the inverse problem in radiation therapy
    • _1990 Properties of an algorithm for solving the inverse problem in radiation therapy Inverse Probl. 6 415-26
    • (1990) Inverse Probl. , vol.6 , pp. 415-426
  • 11
    • 0031220648 scopus 로고    scopus 로고
    • Inverse analysis for magnetic field source searching in thin film conductor
    • Midorikawa Y, Ogawa J, Doi T, Hayano S and Saito Y 1997 Inverse analysis for magnetic field source searching in thin film conductor IEEE Trans. Magn. 33 4008-10
    • (1997) IEEE Trans. Magn. , vol.33 , pp. 4008-4010
    • Midorikawa, Y.1    Ogawa, J.2    Doi, T.3    Hayano, S.4    Saito, Y.5
  • 12
    • 0028891524 scopus 로고
    • The 200-MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization
    • Pedroni E 1995 The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization Med. Phys. 22 37-53
    • (1995) Med. Phys. , vol.22 , pp. 37-53
    • Pedroni, E.1
  • 13
    • 0029018867 scopus 로고
    • Dose calculation in proton beams: Range straggling corrections and energy scaling
    • Russell K, Grusell E and Montelius A 1995 Dose calculation in proton beams: range straggling corrections and energy scaling Phys. Med. Biol. 40 1031-43
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1031-1043
    • Russell, K.1    Grusell, E.2    Montelius, A.3
  • 14
    • 0003179802 scopus 로고
    • A formulation of the inverse problems in magnetostatic fields and its application to a source position searching of the human eye fields
    • Saito Y, Itagaki E and Hayano S 1990 A formulation of the inverse problems in magnetostatic fields and its application to a source position searching of the human eye fields J. Appl. Phys. 67 5830-2
    • (1990) J. Appl. Phys. , vol.67 , pp. 5830-5832
    • Saito, Y.1    Itagaki, E.2    Hayano, S.3
  • 17
    • 0027558398 scopus 로고
    • A neural behaviour estimation by the generalized correlative analysis
    • Saotome H, Kitsuta K, Hayano S and Saito Y 1993 A neural behaviour estimation by the generalized correlative analysis IEEE Trans. Magn. 29 1389-94
    • (1993) IEEE Trans. Magn. , vol.29 , pp. 1389-1394
    • Saotome, H.1    Kitsuta, K.2    Hayano, S.3    Saito, Y.4
  • 19
    • 0031169503 scopus 로고    scopus 로고
    • Shape estimation of radioactive spent resins in a storage lank using the Sampled Pattern Matching
    • Yoda K, Oka T, Tsutaka Y, Usami T, Nakamura H and Umeda Y 1997 Shape estimation of radioactive spent resins in a storage lank using the Sampled Pattern Matching IEEE Trans. Nucl. Sci. 44 1469-73
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 1469-1473
    • Yoda, K.1    Oka, T.2    Tsutaka, Y.3    Usami, T.4    Nakamura, H.5    Umeda, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.