메뉴 건너뛰기




Volumn 14, Issue 4, 1997, Pages 251-254

Retest-reliability and convergent validity of noninvasive blood pressure determination: Arm sphygmomanometry vs. Penaz-method

Author keywords

Arm sphygmomanometry; Blood pressure; Penaz method

Indexed keywords

ADULT; ARM; ARTICLE; BLOOD PRESSURE MONITORING; CLINICAL ARTICLE; CLINICAL TRIAL; DIASTOLIC BLOOD PRESSURE; DIGITAL ARTERY; HUMAN; INTERMETHOD COMPARISON; METHODOLOGY; NORMAL HUMAN; RELIABILITY; SPHYGMOMANOMETRY; SYSTOLIC BLOOD PRESSURE;

EID: 0031455945     PISSN: 01679945     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1016927206619     Document Type: Article
Times cited : (10)

References (14)
  • 3
    • 11244351152 scopus 로고
    • Indirect blood pressure measurement in the finger: Physiological background of a recent development
    • Wesseling KH, Penaz J. Indirect blood pressure measurement in the finger: physiological background of a recent development. Scripta Medica 1986; 59: 203-206
    • (1986) Scripta Medica , vol.59 , pp. 203-206
    • Wesseling, K.H.1    Penaz, J.2
  • 4
    • 0024390372 scopus 로고
    • Noninvasive, continuous measurement of the finger arterial pressure with the servo-plethysmomanometer Finapres
    • Hartmann B, Bassenge E. Noninvasive, continuous measurement of the finger arterial pressure with the servo-plethysmomanometer Finapres. Herz 1989; 14: 251-259
    • (1989) Herz , vol.14 , pp. 251-259
    • Hartmann, B.1    Bassenge, E.2
  • 7
    • 0020061822 scopus 로고
    • The accuracy of the automatic blood pressure measuring device Tonomed: A comparison of direct and indirect measurements
    • Weber F, Anlauf M. The accuracy of the automatic blood pressure measuring device Tonomed: a comparison of direct and indirect measurements. Herz Kreislauf 1982; 14: 279-283
    • (1982) Herz Kreislauf , vol.14 , pp. 279-283
    • Weber, F.1    Anlauf, M.2
  • 8
    • 0023100037 scopus 로고
    • Alerting reaction and rise in blood pressure during measurement by physician and nurse
    • Mancia G, Parati G, Pomidossi G, Grassi G, Casadei R, Zanchetti A. Alerting reaction and rise in blood pressure during measurement by physician and nurse. Hypertension 1987; 9: 209-215
    • (1987) Hypertension , vol.9 , pp. 209-215
    • Mancia, G.1    Parati, G.2    Pomidossi, G.3    Grassi, G.4    Casadei, R.5    Zanchetti, A.6
  • 9
    • 0028027165 scopus 로고
    • Rise in systolic blood pressure during sphygmomanometry depends on the maximum inflation pressure of the arm cuff
    • Kugler J, Schmilz N, Seelbach H, Rollnik J, Krüskemper GM. Rise in systolic blood pressure during sphygmomanometry depends on the maximum inflation pressure of the arm cuff. J Hypertens 1994; 12: 825-829
    • (1994) J Hypertens , vol.12 , pp. 825-829
    • Kugler, J.1    Schmilz, N.2    Seelbach, H.3    Rollnik, J.4    Krüskemper, G.M.5
  • 11
    • 0242687082 scopus 로고
    • American Heart Association report: Recommendations for human blood pressure determinations by sphygmomanometers
    • Kirkendall WM, Feinleb M, Preis ED, Mark AL. American Heart Association report: recommendations for human blood pressure determinations by sphygmomanometers. Circulation 1980; 62: 1145-55A
    • (1980) Circulation , vol.62
    • Kirkendall, W.M.1    Feinleb, M.2    Preis, E.D.3    Mark, A.L.4
  • 14
    • 33749754049 scopus 로고
    • Comparison of Penaz-Method and sphygmomanometry in normo- And mild hypertensives
    • Kugler J, Schmilz N, Seelbach H, Kröber A, Brunk B, Krüskempcr GM. Comparison of Penaz-Method and sphygmomanometry in normo- and mild hypertensives. Am J Hypertens 1992; 5: 128A Address for correspondence: J. Kugler, University Hospital RWTH, Dept. of Medical Psychology, Pauwelstrae 30, D-52057, Aachen, Germany;
    • (1992) Am J Hypertens , vol.5
    • Kugler, J.1    Schmilz, N.2    Seelbach, H.3    Kröber, A.4    Brunk, B.5    Krüskempcr, G.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.